Permanent pacemaker and implantable cardioverter defibrillator infections: seven years of diagnostic and therapeutic experience of a single center.

Mustafa Cengiz1, Sercan Okutucu, Sibel Ascioglu, Abdurrahman Sahin, Hakan Aksoy, Onur Sinan Deveci, Ergun Baris Kaya, Kudret Aytemir, Giray Kabakci, Lale Tokgozoglu, Hilmi Ozkutlu, Ali Oto.   

Abstract

BACKGROUND: Increasing evidence-based indications for the implantation of permanent pacemakers (PMs) and implantable cardioverter defibrillators (ICDs) have led to an increase in the rate of device infections. The aim of the present study was to evaluate infection frequency, clinical characteristics, risk factors, and microbiologic and therapeutic features in patients with PM/ICD infections. HYPOTHESIS: Clinical and demographic characteristics of the patients can affect the PM/ICD infections.
METHODS: The PM/ICD infection group consisted of 57 patients diagnosed and treated with PM/ICD infections in our hospital. The control group in this case-control study consisted of 833 patients in whom a PM or ICD had been implanted and no infections were noted.
RESULTS: Patients with PM/ICD infections (median age 65 years; range, 18-104 years) were older than those without PM/ICD infections (median age 58 years; range, 18-86 years; P = 0.005). The percentage of generator replacement was higher in the PM/ICD infection group compared with the control group (16% vs 8%, P = 0.003). Independent predictors of PM/ICD infections were advanced age (>60 years; odds ratio [OR]: 2.5, 95% confidence interval [CI]: 1.2-4.0, P = 0.021) and device revision (OR: 3.8, 95% CI: 1.5-5.5, P = 0.002). Primary antibiotic prophylaxis during the procedure reduced the risk for PM/ICD infection (OR: 0.5, 95% CI: 0.4-0.8, P = 0.011).
CONCLUSIONS: PM/ICD infections occur in a significant number of patients. It is important to be aware of the risk factors for PM/ICD infections so that patients with an increased risk can be identified and preventive measures can be implemented. Copyright (c) 2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20641117      PMCID: PMC6653156          DOI: 10.1002/clc.20765

Source DB:  PubMed          Journal:  Clin Cardiol        ISSN: 0160-9289            Impact factor:   2.882


  12 in total

1.  Repeated procedures at the generator pocket are a determinant of implantable cardioverter-defibrillator infection.

Authors:  Eduardo Arana-Rueda; Alonso Pedrote; Manuel Frutos-López; Juan Acosta; Beatriz Jauregui; Lorena García-Riesco; Álvaro Arce-León; Federico Gómez-Pulido; Juan A Sánchez-Brotons; Encarnación Gutiérrez-Carretero; Arístides de Alarcón-González
Journal:  Clin Cardiol       Date:  2017-06-21       Impact factor: 2.882

2.  The Diagnosis and Treatment of Pacemaker-Associated Infection.

Authors:  Michael Döring; Sergio Richter; Gerhard Hindricks
Journal:  Dtsch Arztebl Int       Date:  2018-06-29       Impact factor: 5.594

3.  A case of defibrillator-associated infective endocarditis due to Campylobacter fetus.

Authors:  A Sękowska; T Fabiszak; A Mikucka; M Andrzejewska; E Kruszyńska; E Gospodarek; J Klawe
Journal:  Folia Microbiol (Praha)       Date:  2016-07-29       Impact factor: 2.099

4.  New Insights into Predictors of Cardiac Implantable Electronic Device Infection.

Authors:  Hossein Sadeghi; Abolfath Alizadehdiz; Amirfarjam Fazelifar; Zahra Emkanjoo; Majid Haghjoo
Journal:  Tex Heart Inst J       Date:  2018-06-01

5.  Epidemiology of cardiac implantable electronic device infections: incidence and risk factors.

Authors:  Hui-Chen Han; Nathaniel M Hawkins; Charles M Pearman; David H Birnie; Andrew D Krahn
Journal:  Europace       Date:  2021-06-23       Impact factor: 5.214

6.  Safety and feasibility of biventricular devices reuse in general and elderly population--a single-center retrospective cohort study.

Authors:  Raluca Şoşdean; Cristian Mornoş; Bogdan Enache; Răzvan I Macarie; Raluca Ianoş; Ana-Maria Ştefea; Sorin Pescariu
Journal:  Clin Interv Aging       Date:  2015-08-12       Impact factor: 4.458

7.  Clinical manifestations of lead-dependent infective endocarditis: analysis of 414 cases.

Authors:  A Polewczyk; M Janion; R Podlaski; A Kutarski
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2014-05-03       Impact factor: 3.267

8.  Postimplantation pocket hematoma increases risk of cardiac implantable electronic device infection: A meta-analysis.

Authors:  Jakrin Kewcharoen; Chanavuth Kanitsoraphan; Sittinun Thangjui; Thiratest Leesutipornchai; Sakditad Saowapa; Apichai Pokawattana; Leenhapong Navaravong
Journal:  J Arrhythm       Date:  2021-03-13

Review 9.  Cardiac Implantable Electronic Device Infection: From an Infection Prevention Perspective.

Authors:  Sangeeta Sastry; Riaz Rahman; Mohamed H Yassin
Journal:  Adv Prev Med       Date:  2015-10-13