Literature DB >> 20622702

Stereoacuity with simultaneous vision multifocal contact lenses.

Teresa Ferrer-Blasco1, David Madrid-Costa.   

Abstract

PURPOSE: To evaluate near stereoacuity (SA) with Focus Progressives and PureVision Multifocal simultaneous vision contact lenses.
METHODS: In a cross-over study design, 20 presbyopic subjects were fitted with either the Focus Progressives or PureVision Multifocal lenses. After 1 month, SA was measured with the vectographic Titmus, Random dot stereotests, and the Howard-Dolman apparatus under photopic conditions (85 lux) at 40 cm. Binocular high-contrast visual acuity at distance and near was examined. Subjects were then refitted with the alternative correction and the procedure was repeated.
RESULTS: Mean SA with the Focus Progressive was 21 +/- 7 sec arc, 54 +/- 17 sec arc, and 51 +/- 21 sec arc, with the Howard-Dolman, Titmus, and Random dot sterereotests, respectively. These values were 25 +/- 9 sec arc, 74 +/- 26 sec arc, and 82 +/- 26 sec arc with the PureVision Multifocal, respectively. SA was better with the Focus Progressives compared with the PureVision using the Howard-Dolman (4 sec arc of difference; p = 0.001), Titmus (2 sec arc of difference; p = 0.001), and Random dot (31 sec arc of difference; p < 0.001) tests. Binocular mean high-contrast distance visual acuity was similar for the Focus Progressives and PureVision Multifocal: -0.01 +/- 0.07 and +0.02 +/- 0.08 logMAR, respectively (p = 0.074). At near vision, these values were +0.01 +/- 0.07 and +0.06 +/- 0.06 logMAR, respectively, being statistically significant different (p = 0.004).
CONCLUSIONS: Both the Focus Progressive and PureVision Multifocal contact lenses provided good visual acuity preserving stereopsis. Focus Progressives had slightly better near acuity and better SA than the Purevision Multifocal contact lenses. Differences found between the lens types may be related to asphericity, near addition of the contact lens, or even visual acuity differences between the two eyes that were not measured in this study but could conceivably have contributed to SA measure differences. SA measurement with a Howard-Dolman apparatus reveals better SA than vectographic tests.

Entities:  

Mesh:

Year:  2010        PMID: 20622702     DOI: 10.1097/OPX.0b013e3181eb98b9

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  4 in total

1.  Simulated disparity and peripheral blur interact during binocular fusion.

Authors:  Guido Maiello; Manuela Chessa; Fabio Solari; Peter J Bex
Journal:  J Vis       Date:  2014-07-17       Impact factor: 2.240

2.  Effects of Target Size and Test Distance on Stereoacuity.

Authors:  Yo Iwata; Fusako Fujimura; Tomoya Handa; Nobuyuki Shoji; Hitoshi Ishikawa
Journal:  J Ophthalmol       Date:  2016-08-21       Impact factor: 1.909

Review 3.  Bifocal and Multifocal Contact Lenses for Presbyopia and Myopia Control.

Authors:  Laura Remón; Pablo Pérez-Merino; Rute J Macedo-de-Araújo; Ana I Amorim-de-Sousa; José M González-Méijome
Journal:  J Ophthalmol       Date:  2020-03-27       Impact factor: 1.909

4.  Multifocal contact lenses: A bibliometric study.

Authors:  Cristina Alvarez-Peregrina; Miguel Angel Sanchez-Tena; Marina Martin; Cesar Villa-Collar; Francisco Javier Povedano-Montero
Journal:  J Optom       Date:  2020-09-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.