Literature DB >> 20615465

Impact angles as an alternative way to improve aerosolisation of powders for inhalation?

Santoso Adi1, Zhenbo Tong, Hak-Kim Chan, Runyu Yang, Aibing Yu.   

Abstract

This study aims to investigate the role of impact angles on the de-agglomeration performance of powders for inhalation. Agglomerates of a model drug mannitol were impacted at customized impaction throats containing two angles (15-75 degrees and 45-45 degrees) or a single angle (15 degrees, 45 degrees and 90 degrees) using various air flow rates. The mass fraction of fine particles <5microm in the aerosol (FPF(Loaded)) was measured by a liquid impinger coupled to a laser diffractometer. Results showed that for the two-angle throats, there existed an optimal angle (45 degrees) and air flow (120lmin(-1)) for the FPF(Loaded), resulting from a balance between improved de-agglomeration and enhanced throat deposition with increasing air flow. When the throat contained two equal angles of 45 degrees , most powder deposition occurred at the first angle, indicating that the first angle was likely to cause major de-agglomeration, while the second angle might act as a facilitator for further break-up, but the deposition was minimum as the fragment sizes and velocity at the second impaction were smaller. This hypothesis was supported by further studies using single-angle throats and numerical simulation (DEM-CFD). These findings imply the potential importance of using angular design features for multiple impactions to improve DPI performance.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20615465     DOI: 10.1016/j.ejps.2010.06.021

Source DB:  PubMed          Journal:  Eur J Pharm Sci        ISSN: 0928-0987            Impact factor:   4.384


  4 in total

1.  Does the United States Pharmacopeia throat introduce de-agglomeration of carrier-free powder from inhalers?

Authors:  Patricia Tang; Philip Chi Lip Kwok; Zhenbo Tong; Runyu Yang; Judy Agnes Raper; Hak-Kim Chan
Journal:  Pharm Res       Date:  2012-02-11       Impact factor: 4.200

2.  Multi-scale modelling of powder dispersion in a carrier-based inhalation system.

Authors:  Zhenbo Tong; Hidehiro Kamiya; Aibing Yu; Hak-Kim Chan; Runyu Yang
Journal:  Pharm Res       Date:  2014-12-17       Impact factor: 4.200

3.  De-agglomeration Effect of the US Pharmacopeia and Alberta Throats on Carrier-Based Powders in Commercial Inhalation Products.

Authors:  Sharon Shui Yee Leung; Patricia Tang; Qi Tony Zhou; Zhenbo Tong; Cassandra Leung; Janwit Decharaksa; Runyu Yang; Hak-Kim Chan
Journal:  AAPS J       Date:  2015-07-23       Impact factor: 4.009

4.  Aerodynamic factors responsible for the deaggregation of carrier-free drug powders to form micrometer and submicrometer aerosols.

Authors:  P Worth Longest; Yoen-Ju Son; Landon Holbrook; Michael Hindle
Journal:  Pharm Res       Date:  2013-03-08       Impact factor: 4.200

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.