Literature DB >> 20610093

Intrastromal corneal ring segments to correct low myopia in eyes with irregular or abnormal topography including forme fruste keratoconus: 4-year follow-up.

José L Güell1, Merce Morral, Cecilia Salinas, Daniel Elies, Oscar Gris, Felicidad Manero.   

Abstract

PURPOSE: To report the 4-year outcomes after Intacs intrastromal corneal ring segment (ICRS) implantation to correct low myopia in patients with abnormal topography.
SETTING: Instituto de Microcirugia Ocular, Barcelona, Spain.
METHODS: This retrospective consecutive interventional case series included eyes with myopia lower than -4.50 diopters (D) and abnormal topography that excluded excimer laser surgery. Evaluation was performed preoperatively and at yearly intervals up to 4 years postoperatively. The 4-year outcomes measures were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, predictability and stability of refractive correction, the efficacy and safety indices, and complications.
RESULTS: After ICRS implantation, 82.05% of 39 eyes (21 patients) were within +/-1.00 diopter (D) of emmetropia and 46.15% were within +/-0.50 D. Refractive correction improved during the first 6 months and remained stable up to 4 years. The UDVA was 20/40 or better in all eyes and 20/20 or better in 38.46% of eyes. Seven eyes (17.95%) lost 1 line of CDVA, and no eye lost 2 or more lines. No intraoperative complications occurred. The ICRS were exchanged for thicker ICRS in 7 eyes (17.9%) because of undercorrection. One patient requested ICRS removal due to unsatisfactory refractive results.
CONCLUSIONS: The 4-year results indicate that ICRS implantation is effective and safe in the correction of low myopia in patients for whom excimer laser surgery is contraindicated because of abnormal topography, including forme fruste keratoconus. The achieved refractive correction remained stable throughout the follow-up. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20610093     DOI: 10.1016/j.jcrs.2010.01.019

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  3 in total

1.  Clinical outcomes after intrastromal corneal ring segments reoperation in keratoconus patients.

Authors:  Leonardo Torquetti; Guilherme Ferrara; Franklin Almeida; Leandro Cunha; Paulo Ferrara; Jesús Merayo-Lloves
Journal:  Int J Ophthalmol       Date:  2013-12-18       Impact factor: 1.779

2.  [Evaluation and quality assurance of refractive surgery procedures by the German Ophthalmological Society and the Professional Association of German Ophthalmologists. Status: May 2011].

Authors:  T Kohnen; T Neuhann; M Knorz
Journal:  Ophthalmologe       Date:  2011-09       Impact factor: 1.059

3.  Investigation of the efficiency of intrastromal ring segments with cross-linking using different sequence and timing for keratoconus.

Authors:  Xuan-Li Liu; Ping-Hua Li; Pierre Fournie; François Malecaze
Journal:  Int J Ophthalmol       Date:  2015-08-18       Impact factor: 1.779

  3 in total