Literature DB >> 20605669

Effect of cardiopulmonary resuscitation on intubation using a Macintosh laryngoscope, the AirWay Scope, and the gum elastic bougie: A manikin study.

K Maruyama1, S Tsukamoto, S Ohno, K Kobayashi, H Nakagawa, A Kitamura, M Hayashida.   

Abstract

BACKGROUND: Physicians could encounter difficult intubation during cardiopulmonary resuscitation (CPR) in trauma patients due to the patient's movement from continuous chest compression and to cervical stabilisation. Therefore, first, we evaluated the impact of chest compression with or without cervical stabilisation on intubation with a Macintosh laryngoscope. Next, we compared difficulty in intubation among the Macintosh laryngoscope, AirWay Scope (AWS), and gum elastic bougie (GEB) with the Macintosh laryngoscope in three simulated CPR scenarios in a randomised, controlled, cross-over study design.
METHODS: Twenty-three anaesthetists intubated the trachea of a manikin (ALS Skill Master, Laerdal Medical Japan, Tokyo, Japan) using the Macintosh laryngoscope, AWS, and GEB in the control scenario, chest compression scenario, and chest compression with cervical stabilisation scenario. Difficulty in intubation was rated on a 5-point scale and the intubation time was measured.
RESULTS: Continuous chest compression increased difficulty in intubation with the Macintosh laryngoscope, compared with the control scenario. Concurrent application of cervical stabilisation further increased the difficulty, compared with application of chest compression alone. Of the three devices compared, the AWS facilitated the easiest intubation, and the GEB facilitated the second-easiest intubation in all scenarios, though the intubation time was slightly longer with the GEB than with other devices.
CONCLUSION: CPR employing continuous chest compression with or without cervical stabilisation caused difficult intubation with the Macintosh laryngoscope. The AWS and GEB facilitated the easiest and second-easiest intubation, respectively, even during CPR employing continuous chest compression with or without cervical stabilisation in a manikin. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20605669     DOI: 10.1016/j.resuscitation.2010.03.041

Source DB:  PubMed          Journal:  Resuscitation        ISSN: 0300-9572            Impact factor:   5.262


  7 in total

1.  Comparison of Pentax-AWS Airwayscope video laryngoscope, Airtraq optic laryngoscope, and Macintosh laryngoscope during cardiopulmonary resuscitation under cervical stabilization: a manikin study.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Hanako Kohama; Shin-ichi Nishi; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2011-09-07       Impact factor: 2.078

2.  Benefits of using an endotracheal tube introducer as an adjunct to a Macintosh laryngoscope for endotracheal intubation performed by inexperienced doctors during mechanical CPR: A randomized prospective crossover study.

Authors:  Hüseyin Cahit Halhalli; Asım Enes Özbek; Emrah Çelİk; Yavuz Yİğİt; Serkan Yilmaz; Müge Çardak
Journal:  World J Emerg Med       Date:  2019

3.  A Randomized Comparison Simulating Face to Face Endotracheal Intubation of Pentax Airway Scope, C-MAC Video Laryngoscope, Glidescope Video Laryngoscope, and Macintosh Laryngoscope.

Authors:  Hyun Young Choi; Young Min Oh; Gu Hyun Kang; Hyunggoo Kang; Yong Soo Jang; Wonhee Kim; Euichung Kim; Young Soon Cho; Hyukjoong Choi; Hyunjong Kim; Gyoung Yong Kim
Journal:  Biomed Res Int       Date:  2015-06-16       Impact factor: 3.411

4.  Cardiac arrest is a predictor of difficult tracheal intubation independent of operator experience in hospitalized patients.

Authors:  Nita Khandelwal; Richard E Galgon; Marwan Ali; Aaron M Joffe
Journal:  BMC Anesthesiol       Date:  2014-05-22       Impact factor: 2.217

5.  Can the ETView VivaSight SL Rival Conventional Intubation Using the Macintosh Laryngoscope During Adult Resuscitation by Novice Physicians?: A Randomized Crossover Manikin Study.

Authors:  Andrzej Kurowski; Lukasz Szarpak; Zenon Truszewski; Lukasz Czyzewski
Journal:  Medicine (Baltimore)       Date:  2015-05       Impact factor: 1.889

6.  Evaluation of a new laryngoscope according to preparation time.

Authors:  Yasuhiko Imashuku; Hirotoshi Kitagawa; Takayoshi Mizuno
Journal:  Saudi J Anaesth       Date:  2018 Apr-Jun

7.  Utility of a gum-elastic bougie for difficult airway management in infants: a simulation-based crossover analysis.

Authors:  Nobuyasu Komasawa; Akira Hyoda; Sayuri Matsunami; Nozomi Majima; Toshiaki Minami
Journal:  Biomed Res Int       Date:  2015-10-01       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.