Literature DB >> 2060206

Bilateral tibial components of different cementless designs and materials. Microradiographic, backscattered imaging, and histologic analysis.

R D Bloebaum1, D M Rhodes, M H Rubman, A A Hofmann.   

Abstract

Postmortem evaluation was conducted on two cementless knee prostheses considered clinically successful. The two retrieved uncemented porous-coated tibial components of different designs, and materials were evaluated by microradiography, backscattered electron (BSE) imaging, and light microscopy. The right prosthesis, in place for 25 months, was a Porous-Coated Anatomic (PCA) implant with double-layered, sintered, cobalt-chromium alloy beads. The left prosthesis was a Natural-Knee (N-K) implant with a porous coating of cancellous-structured pure titanium implanted for 19 months. A quantitative microradiographic index, the appositional bone index (ABI), was developed to indicate the probability of bone ingrowth occurring into the porous coating. The ABI is a ratio of bone in apposition with porous coating divided by the total amount of porous coating available. The PCA had an average ABI of 9%, and the N-K, 67%. BSE images of the PCA demonstrated no bone within the porous coating. BSE images of the N-K implant showed bone ingrowth into 22% of the pore volume when porous coating was in apposition to host bone. Histology of the PCA revealed fibrous connective tissue throughout the porous coating and between the porous coating-bone interface. Histology of the N-K implant revealed bone ingrowth and osteoblastic activity along the bone within the porous coating.

Entities:  

Mesh:

Year:  1991        PMID: 2060206

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  3 in total

1.  Does using autograft bone chips achieve consistent bone ingrowth in primary TKA?

Authors:  Roy D Bloebaum; Karyn E Koller; Bettina M Willie; Aaron A Hofmann
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  Microscopic analysis of autograft bone applied at the interface of porous-coated devices in human cancellous bone.

Authors:  A A Hofmann; R D Bloebaum; M H Rubman; K N Bachus; R L Plaster
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

3.  In-vivo study of osseointegration in Prestige LP cervical disc prosthesis.

Authors:  Jigang Lou; Beiyu Wang; Tingkui Wu; Wenjie Wu; Huibo Li; Ziyang Liu; Hao Liu
Journal:  BMC Musculoskelet Disord       Date:  2018-02-07       Impact factor: 2.362

  3 in total