Monitoring the eye lens: which dose quantity is adequate?

R Behrens1, G Dietze.   

Abstract

Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. The question of which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens arises from this situation. While in many countries dosemeters calibrated in terms of the dose equivalent quantity H(p)(0.07) have been seen as being adequate for monitoring the dose to the eye lens, this might be questionable in the case of reduced dose limits and, thus, it may become necessary to use the dose equivalent quantity H(p)(3) for this purpose. To discuss this question, the dose conversion coefficients for the equivalent dose of the eye lens (in the following eye lens dose) were determined for realistic photon and beta radiation fields and compared with the values of the corresponding conversion coefficients for the different operational quantities. The values obtained lead to the following conclusions: in radiation fields where most of the dose comes from photons, especially x-rays, it is appropriate to use dosemeters calibrated in terms of H(p)(0.07) on a slab phantom, while in other radiation fields (dominated by beta radiation or unknown contributions of photon and beta radiation) dosemeters calibrated in terms of H(p)(3) on a slab phantom should be used. As an alternative, dosemeters calibrated in terms of H(p)(0.07) on a slab phantom could also be used; however, in radiation fields containing beta radiation with the end point energy near 1 MeV, an overestimation of the eye lens dose by up to a factor of 550 is possible.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20601777     DOI: 10.1088/0031-9155/55/14/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Strict X-ray beam collimation for facial bones examination can increase lens exposure.

Authors:  R Powys; J Robinson; P L Kench; J Ryan; P C Brennan
Journal:  Br J Radiol       Date:  2012-02-28       Impact factor: 3.039

2.  [Eye lens radiation exposure during ureteroscopy with and without a face protection shield: Investigations on a phantom model].

Authors:  G Zöller; M Figel; J Denk; K Schulz; A Sabo
Journal:  Urologe A       Date:  2016-03       Impact factor: 0.639

3.  Risk potentiality of frontline radiotherapy associated cataract in primary ocular adnexal mucosa-associated lymphoid tissue lymphoma.

Authors:  Won-Kyung Cho; Sung-Eun Lee; Ji-Sun Paik; Seok-Goo Cho; Suk-Woo Yang
Journal:  Korean J Ophthalmol       Date:  2013-07-05

4.  Assessment of occupational radiation dose in interventional settings.

Authors:  Fabiola Cretti
Journal:  Med Lav       Date:  2018-02-01       Impact factor: 1.275

5.  Assessment of eye doses to staff involved in interventional cardiology procedures in Kuwait.

Authors:  Meshari Alnaaimi; Mousa Alduaij; Faisal Shenawy; Musab Algaily; Talal Mohammedzein; Mohamed Shaaban; Madan M Rehani
Journal:  Radiat Environ Biophys       Date:  2021-08-05       Impact factor: 1.925

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.