Literature DB >> 20599158

Dynamic contrast-enhanced breast MRI at 7 Tesla utilizing a single-loop coil: a feasibility trial.

Lale Umutlu1, Stefan Maderwald, Oliver Kraff, Jens M Theysohn, Sherko Kuemmel, Elke A Hauth, Michael Forsting, Gerald Antoch, Mark E Ladd, Harald H Quick, Thomas C Lauenstein.   

Abstract

RATIONALE AND
OBJECTIVES: The aim of this study was to assess the feasibility of dynamic contrast-enhanced ultra-high-field breast imaging at 7 Tesla.
MATERIAL AND METHODS: A total of 15 subjects, including 5 patients with histologically proven breast cancer, were examined on a 7 Tesla whole-body magnetic resonance imaging system using a unilateral linearly polarized single-loop coil. Subjects were placed in prone position on a biopsy support system, with the coil placed directly below the region of interest. The examination protocol included the following sequences: 1) T2-weighted turbo spin echo sequence; 2) six dynamic T1-weighted spoiled gradient-echo sequences; and 3) subtraction imaging.
RESULTS: Contrast-enhanced T1-weighted imaging at 7 Tesla could be obtained at high spatial resolution with short acquisition times, providing good image accuracy and a conclusively good delineation of small anatomical and pathological structures. T2-weighted imaging could be obtained with high spatial resolution at adequate acquisition times. Because of coil limitations, four high-field magnetic resonance examinations showed decreased diagnostic value.
CONCLUSIONS: This first scientific approach of dynamic contrast-enhanced breast magnetic resonance imaging at 7 Tesla demonstrates the complexity of ultra-high-field breast magnetic resonance imaging and countenances the implementation of further advanced bilateral coil concepts to circumvent current limitations from the coil and ultra-high-field magnetic strength. 2010 AUR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20599158     DOI: 10.1016/j.acra.2010.03.017

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  14 in total

1.  Diffusion-weighted imaging of breast tumours at 3 Tesla and 7 Tesla: a comparison.

Authors:  S Gruber; L Minarikova; K Pinker; O Zaric; M Chmelik; B Strasser; P Baltzer; T Helbich; S Trattnig; W Bogner
Journal:  Eur Radiol       Date:  2015-08-27       Impact factor: 5.315

2.  Dynamic contrast-enhanced and ultra-high-resolution breast MRI at 7.0 Tesla.

Authors:  Bertine L Stehouwer; Dennis W J Klomp; Maurice A A J van den Bosch; Mies A Korteweg; Kenneth G A Gilhuijs; Arjen J Witkamp; Paul J van Diest; Karel A F Houwert; Wybe J M van der Kemp; Peter R Luijten; W P Th M Mali; Wouter B Veldhuis
Journal:  Eur Radiol       Date:  2013-08-28       Impact factor: 5.315

3.  Clinical application of bilateral high temporal and spatial resolution dynamic contrast-enhanced magnetic resonance imaging of the breast at 7 T.

Authors:  K Pinker; W Bogner; P Baltzer; S Trattnig; S Gruber; O Abeyakoon; M Bernathova; O Zaric; P Dubsky; Z Bago-Horvath; M Weber; D Leithner; T H Helbich
Journal:  Eur Radiol       Date:  2013-12-05       Impact factor: 5.315

4.  Breast MRI at 7 Tesla with a bilateral coil and robust fat suppression.

Authors:  Ryan Brown; Pippa Storey; Christian Geppert; KellyAnne McGorty; Ana Paula Klautau Leite; James Babb; Daniel K Sodickson; Graham C Wiggins; Linda Moy
Journal:  J Magn Reson Imaging       Date:  2013-10-07       Impact factor: 4.813

5.  Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging.

Authors:  Conrad Martin; Tobias Frauenrath; Celal Ozerdem; Wolfgang Renz; Thoralf Niendorf
Journal:  Eur Radiol       Date:  2011-06-08       Impact factor: 5.315

6.  Seven-Tesla MRI of the female pelvis.

Authors:  Lale Umutlu; Oliver Kraff; Anja Fischer; Sonja Kinner; Stefan Maderwald; Kai Nassenstein; Felix Nensa; Johannes Grüneisen; Stephan Orzada; Andreas K Bitz; Michael Forsting; Mark E Ladd; Thomas C Lauenstein
Journal:  Eur Radiol       Date:  2013-05-04       Impact factor: 5.315

7.  [Molecular breast imaging. An update].

Authors:  K Pinker; T H Helbich; H Magometschnigg; B Fueger; P Baltzer
Journal:  Radiologe       Date:  2014-03       Impact factor: 0.635

Review 8.  Clinical role of breast MRI now and going forward.

Authors:  D Leithner; G J Wengert; T H Helbich; S Thakur; R E Ochoa-Albiztegui; E A Morris; K Pinker
Journal:  Clin Radiol       Date:  2017-12-09       Impact factor: 2.350

Review 9.  The potential of multiparametric MRI of the breast.

Authors:  Katja Pinker; Thomas H Helbich; Elizabeth A Morris
Journal:  Br J Radiol       Date:  2016-11-02       Impact factor: 3.039

10.  Breast MRI at 7 Tesla with a bilateral coil and T1-weighted acquisition with robust fat suppression: image evaluation and comparison with 3 Tesla.

Authors:  Ryan Brown; Pippa Storey; Christian Geppert; KellyAnne McGorty; Ana Paula Klautau Leite; James Babb; Daniel K Sodickson; Graham C Wiggins; Linda Moy
Journal:  Eur Radiol       Date:  2013-07-30       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.