BACKGROUND: Medium- and long-term efficacy of intravascular stenting for congenital heart disease (CHD) has not been determined in Japan. METHODS AND
RESULTS: The study comprised a retrospective survey of Palmaz or Palmaz Genesis stent implantation for pulmonary artery stenosis (PA), aortic coarctation, and superior and inferior vena cava lesions (SIVC) from May 1995 to February 2009, occurring in association with pre- or postoperative CHD at 14 leading hospitals. Stents were implanted in 255 patients with 312 lesions (PA, 253 lesions in 199 patients; aorta, 38 lesions in 35 patients; SIVC, 21 lesions in 21 patients). Age at the initial stenting was median 10 years, and the follow-up interval ranged from 6 to 144 months. The minimum lumen diameter (MLD) of the PA, aorta, and SIVC was increased from 4.7+/-2.1, 6.6+/-2.3, and 4.4+/-2.2 mm to 8.8+/-2.7, 12.0+/-3.8, and 9.2+/-2.6 mm, respectively (P<0.01). Cumulative freedom from redilation was 84% at 72 months, 95% at 54 months, and 81% at 50 months, for the PA, aorta, and SIVC, respectively. In 187 redilations, the MLD of the PA, aorta, and SIVC increased from 6.1+/-2.5, 7.9+/-2.9, and 5.3+/-2.4 mm, to 8.3+/-2.7, 9.8+/-3.5, and 7.3+/-1.9 mm, respectively (P<0.01). There were no deaths associated with stent implantation.
CONCLUSIONS: Percutaneous stenting using Palmaz or Palmaz Genesis stents and redilation are now common procedures in Japan with little morbidity during the medium- and long-term follow-up period.

Entities:  

Mesh:

Year:  2010        PMID: 20595775     DOI: 10.1253/circj.cj-10-0157

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  6 in total

1.  Effectiveness and safety of percutaneous transcatheter implantation of pulmonary arterial stent in congenital heart disease.

Authors:  Hong Ki Ko; Young-Hwue Kim; Jeong Jin Yu; Jae-Kon Ko; In-Sook Park; Dong-Man Seo; Tae-Jin Yun; Jeong-Jun Park; Wan Sook Jang
Journal:  Korean Circ J       Date:  2012-01-31       Impact factor: 3.243

2.  Characterization and in vivo evaluation of a bio-corrodible nitrided iron stent.

Authors:  Qimao Feng; Deyuan Zhang; Chaohua Xin; Xiangdong Liu; Wenjiao Lin; Wanqian Zhang; Sun Chen; Kun Sun
Journal:  J Mater Sci Mater Med       Date:  2012-11-27       Impact factor: 3.896

3.  Mechanical properties and in vivo performance of a novel sliding-lock bioabsorbable poly-p-dioxanone stent.

Authors:  Qimao Feng; Wenbo Jiang; Kun Sun; Kang Sun; Sun Chen; Lijiao Zhao; Ke Dai; Ning Ma
Journal:  J Mater Sci Mater Med       Date:  2011-08-06       Impact factor: 3.896

4.  Pulmonary artery stents-still "off label".

Authors:  Seong-Ho Kim
Journal:  Korean Circ J       Date:  2012-01-31       Impact factor: 3.243

5.  Initial status and 3-month results relating to the use of biodegradable nitride iron stents in children and the evaluation of right ventricular function.

Authors:  Ling Sun; Jun-Jie Li; Yu-Kai Xu; Yu-Mei Xie; Shu-Shui Wang; Zhi-Wei Zhang
Journal:  Front Cardiovasc Med       Date:  2022-08-01

6.  The outcome of percutaneous stent implantation in congenital heart disease: experience of a single institute.

Authors:  Moon Sun Kim; Ja Kyoung Yoon; Seong Ho Kim; Ji Seok Bang; So Ick Jang; Sang Yoon Lee; Eun Young Choi; Su Jin Park; Hye Won Kwon
Journal:  Korean J Pediatr       Date:  2018-06-25
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.