Realistic loads for testing hip implants.

G Bergmann1, F Graichen, A Rohlmann, A Bender, B Heinlein, G N Duda, M O Heller, M M Morlock.   

Abstract

The aim here was to define realistic load conditions for hip implants, based on in vivo contact force measurements, and to see whether current ISO standards indeed simulate real loads. The load scenarios obtained are based on in vivo hip contact forces measured in 4 patients during different activities and on activity records from 31 patients. The load scenarios can be adapted to various test purposes by applying average or high peak loads, high-impact activities or additional low-impact activities, and by simulating normal or very active patients. The most strenuous activities are walking (average peak forces 1800 N, high peak forces 3900 N), going up stairs (average peak forces 1900 N, high peak forces 4200 N) and stumbling (high peak forces 11,000 N). Torsional moments are 50% higher for going up stairs than for walking. Ten million loading cycles simulate an implantation time of 3.9 years in active patients. The in vitro fatigue properties of cementless implant fixations are exceeded during stumbling. At least for heavyweight and very active subjects, the real load conditions are more critical than those defined by the ISO standards for fatigue tests.

Entities:  

Mesh:

Year:  2010        PMID: 20592444     DOI: 10.3233/BME-2010-0616

Source DB:  PubMed          Journal:  Biomed Mater Eng        ISSN: 0959-2989            Impact factor:   1.300


  42 in total

1.  Simulated hip abductor strengthening reduces peak joint contact forces in patients with total hip arthroplasty.

Authors:  Casey A Myers; Peter J Laz; Kevin B Shelburne; Dana L Judd; Joshua D Winters; Jennifer E Stevens-Lapsley; Bradley S Davidson
Journal:  J Biomech       Date:  2019-06-06       Impact factor: 2.712

2.  Effect of a collar on subsidence and local micromotion of cementless femoral stems: in vitro comparative study based on micro-computerised tomography.

Authors:  Valérie Malfroy Camine; Hannes A Rüdiger; Dominique P Pioletti; Alexandre Terrier
Journal:  Int Orthop       Date:  2017-06-07       Impact factor: 3.075

3.  Scaling in biomechanical experimentation: a finite similitude approach.

Authors:  Raul Ochoa-Cabrero; Teresa Alonso-Rasgado; Keith Davey
Journal:  J R Soc Interface       Date:  2018-06       Impact factor: 4.118

4.  Zeroth-order finite similitude and scaling of complex geometries in biomechanical experimentation.

Authors:  Raul Ochoa-Cabrero; Teresa Alonso-Rasgado; Keith Davey
Journal:  J R Soc Interface       Date:  2020-06-24       Impact factor: 4.118

5.  [Which hip articulation bearing for which patient? : Tribology of the future].

Authors:  M M Morlock; N Bishop; C Kaddick
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

6.  Tangential Bicortical Locked Fixation Improves Stability in Vancouver B1 Periprosthetic Femur Fractures: A Biomechanical Study.

Authors:  Gregory S Lewis; Cyrus T Caroom; Hwabok Wee; Darin Jurgensmeier; Shane D Rothermel; Michelle A Bramer; John Spence Reid
Journal:  J Orthop Trauma       Date:  2015-10       Impact factor: 2.512

Review 7.  Corrosion of the Head-Stem Taper Junction-Are We on the Verge of an Epidemic?: Review Article.

Authors:  Michael Morlock; Dennis Bünte; Julian Gührs; Nicholas Bishop
Journal:  HSS J       Date:  2016-09-20

8.  The impact of hip implant alignment on muscle and joint loading during dynamic activities.

Authors:  Casey A Myers; Peter J Laz; Kevin B Shelburne; Dana L Judd; Daniel N Huff; Joshua D Winters; Jennifer E Stevens-Lapsley; Paul J Rullkoetter
Journal:  Clin Biomech (Bristol, Avon)       Date:  2018-02-14       Impact factor: 2.063

9.  A biomechanical comparison of locked and unlocked long cephalomedullary nails in a stable intertrochanteric fracture model.

Authors:  Patrick Kane; Bryan Vopat; David Paller; Sarath Koruprolu; Alan H Daniels; Christopher Born
Journal:  J Orthop Trauma       Date:  2014-12       Impact factor: 2.512

Review 10.  Implantable sensor technology: measuring bone and joint biomechanics of daily life in vivo.

Authors:  Darryl D D'Lima; Benjamin J Fregly; Clifford W Colwell
Journal:  Arthritis Res Ther       Date:  2013-01-31       Impact factor: 5.156

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.