Literature DB >> 20591710

Rapid determination of C4-acylcarnitine and C5-acylcarnitine isomers in plasma and dried blood spots by UPLC-MS/MS as a second tier test following flow-injection MS/MS acylcarnitine profile analysis.

Sabrina Forni1, Xiaowei Fu, Susan E Palmer, Lawrence Sweetman.   

Abstract

BACKGROUND: Flow-injection MS/MS methods for elevated acylcarnitines are routinely performed in most newborn screening and biochemical genetics laboratories; however this technique cannot distinguish between isobaric compounds; therefore, chromatographic separation is required to quantitate isomers for differential diagnosis of some inborn errors of metabolism.
METHODS: A UPLC-MS/MS method has been developed for the simultaneous quantitation of isobutyrylcarnitine and butyrylcarnitine, and a second UPLC-MS/MS method for the quantitation of isovalerylcarnitine, (S) and (R) 2-methylbutyrylcarnitine, pivaloylcarnitine and valerylcarnitine. Plasma and dried blood spots samples are extracted with methanol and derivatized with butanolic HCl. Deuterium labeled internal standards are used for quantitation. Separation is obtained using a methanol/water gradient with a C18 BEH, 1x100mm, 1.7microm UPLC column, at 60 degrees C; run time is less than 10min. The isomers are detected with a Quattro Premier triple quadrupole, with electrospray ionization in positive ion mode.
RESULTS: Intra-day precision in plasma and dried blood spots ranged from 1.4% to 14% and accuracy from 88% to 114% respectively for butyrylcarnitine and isobutyrylcarnitine. Precision for the isomers of C5-acylcarnitine ranged from 1.3% to 15% and accuracy 87% to 119%, respectively in plasma or dried blood spots. Inter-day precision was within 20% at each concentration of isobutyrylcarnitine and butyrylcarnitine. Precision for 2-methylbutyrylcarnitine and isovalerylcarnitine at concentrations above the normal range was within 24%.
CONCLUSIONS: Two diagnostic tests based on the separation of C4-acylcarnitine and C5-acylcarnitine isomers by UPLC-MS/MS provide fast differential diagnosis of SCAD deficiency versus IBCD deficiency and IVA versus 2-MBCD deficiency. The separation of C5-acylcarnitines can reveal false elevation due to pivalic acid-containing antibiotics. Abnormal newborn screen results due to pivalate-generating prodrug antibiotics of maternal origin were confirmed. This separation of isomers can resolve multiple diagnostic challenges in both newborn screening and in cases with ambiguous metabolic test results.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20591710     DOI: 10.1016/j.ymgme.2010.05.012

Source DB:  PubMed          Journal:  Mol Genet Metab        ISSN: 1096-7192            Impact factor:   4.797


  7 in total

1.  Application of a second-tier newborn screening assay for c5 isoforms.

Authors:  T Cloppenborg; N Janzen; Hj Wagner; U Steuerwald; M Peter; Am Das
Journal:  JIMD Rep       Date:  2013-11-06

2.  High-Protein Intake during Weight Loss Therapy Eliminates the Weight-Loss-Induced Improvement in Insulin Action in Obese Postmenopausal Women.

Authors:  Gordon I Smith; Jun Yoshino; Shannon C Kelly; Dominic N Reeds; Adewole Okunade; Bruce W Patterson; Samuel Klein; Bettina Mittendorfer
Journal:  Cell Rep       Date:  2016-10-11       Impact factor: 9.423

3.  Validation of a dual LC-HRMS platform for clinical metabolic diagnosis in serum, bridging quantitative analysis and untargeted metabolomics.

Authors:  Ilya Gertsman; Jon A Gangoiti; Bruce A Barshop
Journal:  Metabolomics       Date:  2014-04-04       Impact factor: 4.290

4.  A Simple Flow Injection Analysis-Tandem Mass Spectrometry Method to Reduce False Positives of C5-Acylcarnitines Due to Pivaloylcarnitine Using Reference Ions.

Authors:  Takanari Hattori; Yoshitomo Notsu; Misa Tanaka; Miki Matsui; Tetsuo Iida; Jun Watanabe; Yoshimitsu Osawa; Seiji Yamaguchi; Shozo Yano; Takeshi Taketani; Hironori Kobayashi
Journal:  Children (Basel)       Date:  2022-05-10

Review 5.  Emerging trends in paper spray mass spectrometry: Microsampling, storage, direct analysis, and applications.

Authors:  Benjamin S Frey; Deidre E Damon; Abraham K Badu-Tawiah
Journal:  Mass Spectrom Rev       Date:  2019-09-06       Impact factor: 10.946

Review 6.  Screening newborns for metabolic disorders based on targeted metabolomics using tandem mass spectrometry.

Authors:  Hye-Ran Yoon
Journal:  Ann Pediatr Endocrinol Metab       Date:  2015-09-30

7.  Identification of Six Novel Variants of ACAD8 in Isobutyryl-CoA Dehydrogenase Deficiency With Increased C4 Carnitine Using Tandem Mass Spectrometry and NGS Sequencing.

Authors:  Dan-Yan Zhuang; Shu-Xia Ding; Fei Wang; Xiang-Chun Yang; Xiao-Li Pan; You-Wei Bao; Li-Ming Zhou; Hai-Bo Li
Journal:  Front Genet       Date:  2022-01-28       Impact factor: 4.599

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.