PURPOSE: To report on the 12-month follow-up of 77 eyes with moderate to high myopic astigmatism implanted with toric implantable collamer lenses (ICLs). METHODS: Retrospective case-note review of 77 eyes from 42 patients undergoing toric ICL placement by one surgeon. Preoperative mean spherical equivalent -2.50 dioptres (D) to -15.00 D myopia and 1.00 D to 7.00 D astigmatism. RESULTS: At 12 months, mean manifest refractive cylinder (MRC) decreased 81% from 2.38 D to 0.44 D. MRC within 1.00 D occurred in 99% (76/77) of eyes, whereas 86% (66/77) had MRC within 0.75 D. 99% (76/77) had postoperative best-corrected visual acuity (BCVA) better than or equal to preoperative values, whereas 78% (60/77) gained up to one line BCVA and 1% (1/77) lost one line BCVA. Uncorrected binocular vision of 6/6 or better occurred in 90% (38/42) of patients compared with binocular BCVA of 6/6 or better in 67% (28/42) preoperatively. One ICL was replaced due to low vaulting. Two eyes with astigmatism of 3.25 D and 3.50 D received subsequent laser in situ keratomileusis (LASIK) to reduce residual small refractive errors. Indications for ICL were: myopia too high for LASIK (73%), cornea too thin for LASIK (44%) and contact lens intolerance (33%). Night halos were reported in 10% (8/77) of eyes at 12 months. One ICL was removed due to unrecognized preoperative glaucoma. There were no cases of cataract formation, or endophthalmitis. CONCLUSION: This study is the largest reported series of toric ICL implantation in New Zealand. It supports the safety, efficacy and predictability of toric ICLs to treat myopic astigmatism.
PURPOSE: To report on the 12-month follow-up of 77 eyes with moderate to high myopic astigmatism implanted with toric implantable collamer lenses (ICLs). METHODS: Retrospective case-note review of 77 eyes from 42 patients undergoing toric ICL placement by one surgeon. Preoperative mean spherical equivalent -2.50 dioptres (D) to -15.00 D myopia and 1.00 D to 7.00 D astigmatism. RESULTS: At 12 months, mean manifest refractive cylinder (MRC) decreased 81% from 2.38 D to 0.44 D. MRC within 1.00 D occurred in 99% (76/77) of eyes, whereas 86% (66/77) had MRC within 0.75 D. 99% (76/77) had postoperative best-corrected visual acuity (BCVA) better than or equal to preoperative values, whereas 78% (60/77) gained up to one line BCVA and 1% (1/77) lost one line BCVA. Uncorrected binocular vision of 6/6 or better occurred in 90% (38/42) of patients compared with binocular BCVA of 6/6 or better in 67% (28/42) preoperatively. One ICL was replaced due to low vaulting. Two eyes with astigmatism of 3.25 D and 3.50 D received subsequent laser in situ keratomileusis (LASIK) to reduce residual small refractive errors. Indications for ICL were: myopia too high for LASIK (73%), cornea too thin for LASIK (44%) and contact lens intolerance (33%). Night halos were reported in 10% (8/77) of eyes at 12 months. One ICL was removed due to unrecognized preoperative glaucoma. There were no cases of cataract formation, or endophthalmitis. CONCLUSION: This study is the largest reported series of toric ICL implantation in New Zealand. It supports the safety, efficacy and predictability of toric ICLs to treat myopic astigmatism.
Authors: Majid Moshirfar; Robert J Thomson; William B West Jnr; Shannon E McCabe; Thomas M Sant; Margaret H Shmunes; Yasmyne C Ronquillo; Phillip C Hoopes Journal: Clin Ophthalmol Date: 2020-12-09