Majid Moshirfar1,2,3, Robert J Thomson4, William B West Jnr5, Shannon E McCabe1,6, Thomas M Sant5, Margaret H Shmunes7, Yasmyne C Ronquillo1, Phillip C Hoopes1.
Abstract
PURPOSE: To report the outcomes of sequential posterior chamber phakic intraocular lens (PC-pIOL) with corneal refractive surgery in conventional (PC-pIOL prior to refractive surgery) and reverse (refractive surgery prior to PC-pIOL) bioptics for treating high myopic astigmatism.Entities:
Keywords: LASIK; PRK; bioptics; high myopic astigmatism; posterior chamber phakic IOL; visual outcomes
Year: 2020 PMID: 33328722 PMCID: PMC7734069 DOI: 10.2147/OPTH.S285140
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Preoperative Baseline Characteristics for Eyes That Underwent Conventional Bioptics and Reverse Bioptics
| Conventional Bioptics | Reverse Bioptics | P value | |
|---|---|---|---|
| Number of eyes (patients) | 87 (49) | 13 (7) | – |
| M/F (eyes) | 41:46 | 4:8 | – |
| PRK/LASIK (eyes) | 61:26 | 2:11 | – |
| Mean age (range) (y) | 33.1 (21 to 56) | 33.7 (21 to 45) | 0.82 |
| Time between procedures (month)* | 3.8 ± 2.1 (1 to 10) | 2.67 ± 2.1 (1 to 7) | 0.07 |
| UDVA* | 1.56 ± 0.32 (1.00 to 3.00) | 1.56 ± 0.12 (1.48 to 1.90) | 0.97 |
| CDVA* | 0.03 ± 0.09 (0.00 to +0.40) | 0.11 ± 0.10 (0.00 to +0.30) | <0.01* |
| SEQ (D)* | −11.12 ± 3.39 (−19.88 to −3.38) | −12.42 ± 1.81 (−15.38 to −9.13) | < 0.01* |
| Refractive cylinder (D)* | −2.49 ± 1.16 (−6.00 to −0.50) | −3.88 ± 1.43 (−6.75 to −2.00) | < 0.01* |
Notes: Visual acuity reported as LogMAR. *Values reported as mean ± SD (range). Monovision eyes were excluded from UDVA analysis.
Abbreviations: UDVA, uncorrected distance visual acuity; CDVA, corrected distance visual acuity; SEQ, spherical equivalent refraction.
Pre- and Postoperative Visual Outcomes at Postoperative Time Points
| Preop | 1mo | 3mo | 6mo | 12mo | |
|---|---|---|---|---|---|
| Number of eyes (patients) | 100 (56) | 83 (47) | 77 (44) | 61 (36) | 51 (30) |
| UDVA | 1.56 ± 0.30 (1.00 to 3.00) | 0.09 ± 0.13 (−0.12 to +0.48) | 0.03 ± 0.11 (−0.12 to +0.40) | 0.04 ± 0.13 (−0.12 to +0.40) | 0.02 ± 0.12 (−0.12 to +0.30) |
| CDVA | 0.04 ± 0.09 (0.00 to +0.40) | 0.03 ± 0.10 (−0.12 to +0.40) | −0.01 ± 0.10 (−0.12 to +0.30) | −0.01 ± 0.10 (−0.12 to+ 0.30) | −0.01 ± 0.10 (−0.12 to +0.30) |
| SEQ (D) | −11.30 ± 3.25 (−19.88 to −3.38) | −0.15 ± 0.46 (−1.50 to +1.13) | 0.01 ± 0.35 (−0.50 to +1.13) | −0.03 ± 0.34 (−0.63 to +1.13) | −0.08 ± 0.31 (−0.88 to +0.75) |
| Refractive cylinder (D) | −2.67 ± 1.29 (−6.75 to −0.50) | −0.49 ± 0.36 (−1.50 to 0.00) | −0.41 ± 0.32 (−1.50 to 0.00) | −0.41 ± 0.31 (−1.25 to 0.00) | −0.42 ± 0.34 (−1.25 to 0.00) |
Notes: Visual acuity is reported as LogMAR. Values reported as mean ± SD (range). Monovision eyes were excluded from UDVA analysis.
Abbreviations: UDVA, uncorrected distance visual acuity; CDVA, corrected distance visual acuity; SEQ, spherical equivalent refraction.
Figure 1Visual and refractive outcomes for eyes at 3 and 12 months postoperatively following all bioptics procedures. UDVA values of monovision eyes were not included. (A) Cumulative postoperative UDVA and preoperative CDVA. (B) Difference in postoperative UDVA and CDVA. (C) Change in CDVA. (D) Attempted vs achieved SEQ.
Figure 2Outcomes of refractive astigmatism for myopic eyes at 3 and 12 months postoperatively following all bioptics procedures. (A) Magnitude of TIA versus the magnitude of SIA. (B) Change in refractive astigmatic magnitude. (C) Postoperative angle of error.
Figure 3Stability of bioptics procedures reported as mean SEQ at 1 week and 1, 3, 6, and 12 months postoperatively.
Efficacy and Safety Index for Eyes That Underwent Conventional Bioptics and Reverse Bioptics
| Efficacy Index | Safety Index | |||||
|---|---|---|---|---|---|---|
| Postop | C Bioptics [Eyes] | R Bioptics [Eyes] | P value | C Bioptics [Eyes] | R Bioptics [Eyes] | P value |
| 1 mo | 0.87 ± 0.23 (0.40 to 1.50) [69] | 1.24 ± 0.32 (1.00 to 2.00) [11] | <0.01* | 1.00 ± 0.20 (0.50 to 1.67) [72] | 1.39 ± 0.24 (1.25 to 2.00) [11] | <0.01* |
| 3 mo | 1.01 ± 0.20 (0.67 to 1.67) [67] | 1.28 ± 0.24 (0.67 to 1.33) [7] | 0.06 | 1.11 ± 0.19 (0.67 to 1.67) [70] | 1.25 ± 0.12 (1 to 1.33) [7] | 0.09 |
| 6 mo | 1.02 ± 0.22 (0.50 to 1.60) [49] | 1.10 ± 0.30 (0.63 to 1.67) [9] | 0.95 | 1.12 ± 0.18 (0.80 to 1.67) [52] | 1.30 ± 0.20 (1.00 to 1.67) [9] | 0.16 |
| 12 mo | 1.08 ± 0.20 (0.67 to 1.67) [41] | 0.99 ± 0.42 (0.50 to 1.60) [7] | 0.56 | 1.13 ± 0.22 (0.80 to 1.67) [44] | 1.15 ± 0.38 (1.00 to 2.00) [7] | 0.49 |
Notes: Values reported as mean ± SD (range) [number of eyes]. Monovision eyes were excluded from efficacy index analysis. *Statistically significant.
Abbreviations: C Bioptics, conventional bioptics; R Bioptics, reverse bioptics.
Postoperative Spherical Equivalent Refraction and Refractive Cylinder in Eyes That Underwent Conventional Bioptics and Reverse Bioptics
| Spherical Equivalent Refraction (D) | Refractive Cylinder (D) | |||||
|---|---|---|---|---|---|---|
| C Bioptics | R Bioptics | P value | C Bioptics | R Bioptics | P value | |
| Preop | −11.12 ± 3.39 (−19.88 to −3.38) [83] | −12.42 ± 1.81 (−15.38 to −9.13) [13] | <0.01* | −2.49 ± 1.16 (−6.00 to −0.50) [87] | −3.88 ± 1.43 (−6.75 to −2.00) [13] | <0.01* |
| Postop 1 mo | −0.16 ± 0.49 (−1.50 to +1.13) [69] | −0.15 ± 0.22 (−0.38 to +0.38) [11] | 0.96 | −0.50 ± 0.37 (−1.50 to 0.00) | −0.43 ± 0.32 (−0.75 to 0.00) [11] | 0.70 |
| 3 mo | 0.01 ± 0.37 (−0.50 to +1.13) [67] | 0.00 ± 0.19 (−0.25 to +0.38) [7] | 0.57 | −0.38 ± 0.31 (−1.50 to 0.00) [70] | −0.71 ± 0.25 (−1.25 to −0.50) [7] | <0.01* |
| 6 mo | −0.05 ± 0.33 (−0.63 to +1.13) [49] | 0.06 ± 0.41 (−0.63 to +0.88) [9] | 0.47 | −0.38 ± 0.32 (−1.25 to 0.00) [52] | −0.56 ± 0.23 (−1.00 to −0.25) [9] | 0.23 |
| 12 mo | −0.08 ± 0.33 (−0.88 to +0.75) [41] | −0.11 ± 0.18 (−0.25 to +0.25) [7] | 0.69 | −0.40 ± 0.33 (−1.25 to 0.00) [44] | −0.50 ± 0.38 (−1.00 to 0.00) [7] | 0.53 |
Notes: Values reported as mean ± SD (range) [number of eyes]. Monovision eyes were excluded from spherical equivalent refraction analysis. *Statistically significant.
Abbreviations: C Bioptics, conventional bioptics; R Bioptics, reverse bioptics.
Figure 4PC-pIOL vaults recorded within 6 months prior to and after LASIK/PRK in conventional bioptics. (P = 0.71).