Literature DB >> 20583304

Characterization of protein degradation in serum-based lubricants during simulation wear testing of metal-on-metal hip prostheses.

Victoria K Maskiewicz1, Paul A Williams2, Sarah J Prates1, John G Bowsher3, Ian C Clarke3.   

Abstract

A size exclusion high performance liquid chromatography (SEC-HPLC) method has been developed which is capable of separation and quantitation of bovine serum albumin (BSA) and bovine serum globulin (BSG) components of serum-based lubricant (SBL) solutions. This allowed characterization of the stability profiles of these proteins when acting as lubricants during hip wear simulation, and identification of wear-specific mechanisms of degradation. Using cobalt-chromium metal-on-metal (MOM) hip joints, it was observed that BSA remained stable for up to 3 days (215K cycles) of wear testing after which the protein degraded in a fairly linear fashion. BSG on the other hand, began to degrade immediately and in a linear fashion with a rate constant of 5% per day. Loss of both proteins occurred via the formation of high molecular weight aggregates which precipitated out of solution. No fragmentation of the polypeptide backbone of either protein was observed. Data obtained suggest that protein degradation was not due to microbial contamination, denaturation at the air-water interface, or frictional heating of articulating joint surfaces in these studies. We conclude that the primary source of protein degradation during MOM simulation testing occurs via high shear rates experienced by SBL solutions at articulating surfaces, possibly coupled with metal-protein interactions occurring as new and reactive metal surfaces are generated during wear testing. The development of this analytical methodology will allow new studies to clarify the role of SBL solutions in wear simulation studies and the interactions and lubricating properties of serum proteins with prosthetic surfaces other than MOM.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20583304     DOI: 10.1002/jbm.b.31671

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  3 in total

1.  Metal-on-metal total hip arthroplasty: is there still a role in 2016?

Authors:  Edward J Silverman; Blair Ashley; Neil P Sheth
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

2.  CoCrMo metal-on-metal hip replacements.

Authors:  Yifeng Liao; Emily Hoffman; Markus Wimmer; Alfons Fischer; Joshua Jacobs; Laurence Marks
Journal:  Phys Chem Chem Phys       Date:  2013-01-21       Impact factor: 3.676

3.  Wear Simulation of Ceramic-on-Crosslinked Polyethylene Hip Prostheses: A New Non-Oxide Silicon Nitride versus the Gold Standard Composite Oxide Ceramic Femoral Heads.

Authors:  Makiko Yorifuji; Saverio Affatato; Toshiyuki Tateiwa; Yasuhito Takahashi; Takaaki Shishido; Elia Marin; Matteo Zanocco; Wenliang Zhu; Giuseppe Pezzotti; Kengo Yamamoto
Journal:  Materials (Basel)       Date:  2020-06-29       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.