Spectrophotometric estimation of olmesartan medoxomil and hydrochlorothiazide in tablet.

A R Rote1, P D Bari.   

Abstract

A simultaneous determination of olmesartan medoxomil and hydrochlorothiazide by absorption ratio spectrophotometric method has been developed in combined tablet dosage form. The method is based on measurements of absorbance at isoabsoptive point. The Beer's law obeys in the range of 10-30 mug/ml for both olmesartan medoxomil and hydrochlorothiazide respectively. The proposed method was validated by performing recovery study and statistically.

Entities:  

Keywords:  Hydrochlorothiazide; Olmesartan medoxomil; UV spectrophotometry

Year:  2010        PMID: 20582200      PMCID: PMC2883210          DOI: 10.4103/0250-474X.62245

Source DB:  PubMed          Journal:  Indian J Pharm Sci        ISSN: 0250-474X            Impact factor:   0.975


Olmesartan medoxomil (OLM) is a prodrug and is hydrolyzed to the active olmesartan during absorption from the gastrointestinal tract. Olmesartan is a selective AT1 subtype angiotensin II receptor antagonist. It is chemically, 2,3-dihydroxy-2-butenyl4-(1-hydroxy-1-methylethyl)-2-propyl-1-[p-(o-1Htetrazol-5-ylphenyl)benzyl]imidazole-5-carboxylate, cyclic-2,3-carbonate. Hydrochlorothiazide (HCT) is one of the oldest and widely used thiazide diuretics. A literature survey revealed that OLM is not yet official in any pharmacopoeia. Several analytical methods have been reported for the determination of olmesartan medoxomil in biological fluids includes LC-MS-MS[1], degradation product HPLC[2], HPTLC[3]. One analytical method was developed for determination of HCT and OLM in combination HPLC[4], The USP described an HPLC method for determination of HCT from tablet formulation[5]. A double beam, Shimadzu 2450 UV/Vis spectrophotometer connected to a HCL computer loaded with UV Probe 2.21 Software was used in the current investigation. OLM and HCT were supplied by Glenmark Pharmaceutical Ltd and Ajanta Pharmaceuticals Ltd, respectively. Sodium hydroxide and double distilled water were used for this work. A commercial pharmaceutical preparation Olmesar-H of Macleod, Gujarat, India (containing OLM 20 mg and HCT 12.5 mg/tablet) was used for analysis. Standard stock solution 1.0 mg/ml each of OLM and HCT were prepared in 25 ml 0.1 N NaOH. A further dilution of stock solution was made with 0.1 N NaOH to get a working standard solution of 100 μg/ml of both drugs. Then 10 ml of OLM and 6.25 ml of HCT standard stock solution of each drug was taken in 50 ml volumetric flask and diluted with 0.1 N NaOH up to the mark to get 200 μg/ml of OLM and 125 μg/ml of HCT. This solution used as standard working mixture solution. From the standard working mixture solution of OLM and HCT, 1 ml of working mixture were taken in 10 ml volumetric flask containing 20 μg/ml of OLM and 12.5 μg/ml of HCT were prepared using 0.1 N NaOH. The standard mixtures prepared were then scanned over the range of UV 200 to 360 nm. The spectra were then obtained and absorbance was measured at selected wavelengths 260.0 nm (isoabsorptive point) and 272.8 nm for both the drugs. The concentrations of OLM and HCT were calculated by inserting the absorbance values in the Eqns. , where Cx and CY are concentration of OLM and HCT (g/100 ml), respectively, A1 and A2 are absorbance of mixture at 248.6 nm and 272.8 nm, respectively, ax1 and ax2 denote absorptivity of OLM at 260.0 nm and 272.8 nm, respectively, ay1 and ay2 represent absorptivity of HCT at 260.0 nm and 272.8 nm, respectively, Qx and QY are ratios of absorptivity of OLM and HCT at 272.8 nm and 260.0 nm, respectively and Qm is the ratio of absorbance of the mixture at 272.6 nm and 260.0 nm. Linearity was constructed in the range 10-30 μg/ml for both OLM and HCT, respectively. This shows regression coefficient 0.9999 for OLM at 248.6 nm and 0.9991 for HCT at 272.8 nm. The statistical parameters were calculated. Twenty tablets were weighed accurately and powdered. Powder equivalent to 20 mg of OLM (containing 12.5 mg of HCT) was weighed and transferred to 100 ml volumetric flask and dissolved in 25 ml methanol by shaking the flask for 15 min and volume was made up to the mark with 0.1 N NaOH. The solution was filtered through Whatman filter paper No. 41. One millilitre aliquot of sample stock solution was transferred to 10 ml volumetric flask and volume was made up to mark with 0.1 N NaOH to get concentration of 20 μg/ml of OLM and 12.5 μg/ml of HCT. The solutions were then scanned over the range of 200 to 360 nm. The spectra were obtained and absorbance was measured at selected wavelengths 260.0 nm (isoabsorptive point) and 272.8 nm for both the drugs. The concentrations of OLM and HCT were calculated by putting the absorbance values in Eqns. 1 and 2. The accuracy of the proposed method was checked by performing recovery study by addition of standard drug solution to preanalysed tablet sample solution at three different concentration levels (80, 100 and 120%) within the range of linearity for both the drugs. The wavelengths selected for this method should be wavelength (λmax) one of the component and second one was the isoabsorptive point where the absorptivity of both components was same which is shown in fig. 1. OLM shows maximum absorption at wavelength (λmax) 248.6 nm, where as the HCT shows maximum absorption at wavelength (λmax) 272.8 nm and 260.0 nm is the isoabsorptive point of both drugs. The analytical data for the linearity range shows correlation coefficients of 0.9999 for Olmesartan medoxomil and 0.9991 for HCT at 248.6 nm and 272.8 nm, respectively which is shown in Table 1. For quantitative analysis, concentration of OLM and HCT in tablet sample were determined by using Eqns. 1 and 2, results are shown in Table 2. The detection limits were 0.41 μg/ml for OLM and 0.44 μg/ml for HCT, while quantification limit were 1.25 μg/ml for OLM and 1.33 μg/ml for HCT. The proposed method was validated by performing recovery study. Recovery was in the range of 99.97-100.62 % for OLM and HCT respectively, the standard deviation was found to be less than 2%, shows the high precision of the proposed method The method can be used for the routine quality control analysis of the OLM and HCT in combined dosage form.
Fig. 1

Overlay of Spectra of OLM and HCT

OLM is olmesartan medoximil and HCT is hydrochlorthiazide

TABLE 1

OPTICAL CHARACTERISTICS OF PROPOSED METHOD

ParameterOLMHCT
Beer' law limit (μg/ml)10-3010-30
Régression Equation (y = mx + c)--
Slope (m)0.0430.0526
Intercept (c)-0.0031-0.0103
Correlation coefficient0.99990.9991
Limit of detection (LOD, μg/ml)0.410.44
Limit of quantitation (LOQ, μg/ml)1.251.33
TABLE 2

RESULTS OF COMMERCIAL TABLET FORMULATION ANALYSIS

ParameterOLMHCT
Label claim(mg/tablet)2012.5
Mean*100.18100.75
±Standard Deviation0.50070.4256
±SE0.22390.1903
% RSD0.49980.4224

average of 5 determinants

Overlay of Spectra of OLM and HCT OLM is olmesartan medoximil and HCT is hydrochlorthiazide OPTICAL CHARACTERISTICS OF PROPOSED METHOD RESULTS OF COMMERCIAL TABLET FORMULATION ANALYSIS average of 5 determinants
  2 in total

1.  Quantitative determination of olmesartan in human plasma and urine by liquid chromatography coupled to tandem mass spectrometry.

Authors:  Dongyang Liu; Pei Hu; Nobuko Matsushima; Xiaoming Li; Li Li; Ji Jiang
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2007-06-16       Impact factor: 3.205

2.  Identification of a degradation product in stressed tablets of olmesartan medoxomil by the complementary use of HPLC hyphenated techniques.

Authors:  Tomonori Murakami; Hidetoshi Konno; Naoto Fukutsu; Michinobu Onodera; Takao Kawasaki; Fumiyo Kusu
Journal:  J Pharm Biomed Anal       Date:  2008-02-29       Impact factor: 3.935

  2 in total
  4 in total

1.  Multivariate versus classical univariate calibration methods for spectrofluorimetric data: application to simultaneous determination of olmesartan medoxamil and amlodipine besylate in their combined dosage form.

Authors:  Hany W Darwish; Ahmed H Backeit
Journal:  J Fluoresc       Date:  2012-08-16       Impact factor: 2.217

2.  Application of a Stability-Indicating HPTLC Method for Simultaneous Quantitative Determination of Olmesartan Medoxomil and Hydrochlorothiazide in Pharmaceutical Dosage Forms.

Authors:  Kaliappan Ilango; Pushpangadhan S Shiji Kumar
Journal:  J Anal Methods Chem       Date:  2013-11-04       Impact factor: 2.193

3.  Method Validation for Simultaneous Quantification of Olmesartan and Hydrochlorothiazide in Human Plasma Using LC-MS/MS and Its Application Through Bioequivalence Study in Healthy Volunteers.

Authors:  Arvind Kumar; Surya Prakash Dwivedi; Tulika Prasad
Journal:  Front Pharmacol       Date:  2019-07-23       Impact factor: 5.810

4.  Central Composite Design for Validation of HPTLC Method for Simultaneous Estimation of Olmesartan Medoxomil, Amlodipine Besylate and Hydrochlorothiazide in Tablets.

Authors:  Trupti B Solanki; Purvi A Shah; Kalpana G Patel
Journal:  Indian J Pharm Sci       Date:  2014-05       Impact factor: 0.975

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.