AIMS: The density of vasa vasorum within atherosclerotic plaque correlates with histologic features of plaque vulnerability in post-mortem studies. Imaging methods to non-invasively detect vasa vasorum are limited. We hypothesized that contrast ultrasound (CUS) can quantify vasa vasorum during atherosclerosis progression. METHODS AND RESULTS: New Zealand white rabbits received a high-fat diet for 3 weeks, and bilateral femoral artery stenosis was induced by balloon injury. Contrast ultrasound femoral imaging was performed at baseline and 2, 4, and 6 weeks post injury to quantify adventitial videointensity. At each imaging time point 10 vessels were sectioned and stained with haematoxylin and eosin and von-Willebrand factor. Adventitial vasa vasorum density was quantified by counting the number of stained microvessels and their total cross-sectional area. Plaque size (per cent lumen area) progressed over time (P < 0.001), as did adventitial vasa vasorum density (P < 0.001). Plateau peak videointensity also progressed, demonstrating a strong linear correlation with histologic vasa vasorum density (P < 0.001). Receiver operating characteristic analysis indicated that a three-fold increase in median adventitial videointensity had a sensitivity of 100% and specificity of 88% for predicting abnormal neovascularization. CONCLUSION: We have histologically validated that CUS quantifies the development of adventitial vasa vasorum associated with atherosclerosis progression. This imaging technique has the potential for characterizing prognostically significant plaque features.
AIMS: The density of vasa vasorum within atherosclerotic plaque correlates with histologic features of plaque vulnerability in post-mortem studies. Imaging methods to non-invasively detect vasa vasorum are limited. We hypothesized that contrast ultrasound (CUS) can quantify vasa vasorum during atherosclerosis progression. METHODS AND RESULTS: New Zealand white rabbits received a high-fat diet for 3 weeks, and bilateral femoral artery stenosis was induced by balloon injury. Contrast ultrasound femoral imaging was performed at baseline and 2, 4, and 6 weeks post injury to quantify adventitial videointensity. At each imaging time point 10 vessels were sectioned and stained with haematoxylin and eosin and von-Willebrand factor. Adventitial vasa vasorum density was quantified by counting the number of stained microvessels and their total cross-sectional area. Plaque size (per cent lumen area) progressed over time (P < 0.001), as did adventitial vasa vasorum density (P < 0.001). Plateau peak videointensity also progressed, demonstrating a strong linear correlation with histologic vasa vasorum density (P < 0.001). Receiver operating characteristic analysis indicated that a three-fold increase in median adventitial videointensity had a sensitivity of 100% and specificity of 88% for predicting abnormal neovascularization. CONCLUSION: We have histologically validated that CUS quantifies the development of adventitial vasa vasorum associated with atherosclerosis progression. This imaging technique has the potential for characterizing prognostically significant plaque features.
Authors: Johannes A Schaar; Chris L De Korte; Frits Mastik; Chaylendra Strijder; Gerard Pasterkamp; Eric Boersma; Patrick W Serruys; Anton F W Van Der Steen Journal: Circulation Date: 2003-10-27 Impact factor: 29.690
Authors: Edoardo Vicenzini; Maria Fabrizia Giannoni; Francesco Puccinelli; Maria Chiara Ricciardi; Marta Altieri; Vittorio Di Piero; Bruno Gossetti; Fabrizio Benedetti Valentini; Gian Luigi Lenzi Journal: Stroke Date: 2007-08-30 Impact factor: 7.914
Authors: Stephanie H Wilson; Joerg Herrmann; Lilach O Lerman; David R Holmes; Claudio Napoli; Erik L Ritman; Amir Lerman Journal: Circulation Date: 2002-01-29 Impact factor: 29.690
Authors: Judith C Sluimer; Frank D Kolodgie; Ann P J J Bijnens; Kimberly Maxfield; Erica Pacheco; Bob Kutys; Hans Duimel; Peter M Frederik; Victor W M van Hinsbergh; Renu Virmani; Mat J A P Daemen Journal: J Am Coll Cardiol Date: 2009-04-28 Impact factor: 24.094
Authors: M F Giannoni; E Vicenzini; M Citone; M C Ricciardi; L Irace; A Laurito; L F Scucchi; V Di Piero; B Gossetti; A Mauriello; L G Spagnoli; G L Lenzi; F B Valentini Journal: Eur J Vasc Endovasc Surg Date: 2009-03-27 Impact factor: 7.069
Authors: Falak Shah; Prakash Balan; Matthew Weinberg; Vijaya Reddy; Rachel Neems; Matthew Feinstein; John Dainauskas; Peter Meyer; Marshall Goldin; Steven B Feinstein Journal: Vasc Med Date: 2007-11 Impact factor: 3.239
Authors: Li Dong; Williams S Kerwin; Huijun Chen; Baocheng Chu; Hunter R Underhill; Moni Blazej Neradilek; Thomas S Hatsukami; Chun Yuan; Xue-Qiao Zhao Journal: Radiology Date: 2011-04-14 Impact factor: 11.105
Authors: Kirsti A Campbell; Michael J Lipinski; Amanda C Doran; Marcus D Skaflen; Valentin Fuster; Coleen A McNamara Journal: Circ Res Date: 2012-03-16 Impact factor: 17.367
Authors: Jie Sun; Yan Song; Huijun Chen; William S Kerwin; Daniel S Hippe; Li Dong; Min Chen; Cheng Zhou; Thomas S Hatsukami; Chun Yuan Journal: Stroke Date: 2013-03-07 Impact factor: 7.914
Authors: Qiyang Chen; Jaesok Yu; Lyudmila Lukashova; Joseph D Latoche; Jianhui Zhu; Linda Lavery; Konstantinos Verdelis; Carolyn J Anderson; Kang Kim Journal: IEEE Trans Ultrason Ferroelectr Freq Control Date: 2020-02-18 Impact factor: 2.725