PURPOSE: To investigate the short-term reproducibility of black-blood dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) in atherosclerotic rabbits to evaluate the potential of this technique to be a reliable readout of plaque progression and/or regression upon therapeutic intervention. MATERIALS AND METHODS: Atherosclerotic rabbits were imaged at baseline and 24 hours later with DCE-MRI on a 1.5T MRI system. DCE-MRI images were analyzed by calculating the area under the signal intensity versus time curve (AUC). Intraclass correlation coefficients (ICCs) were used to evaluate interscan, intraobserver, and interobserver reproducibility. In addition, the test-retest coefficient of variation (CoV) was evaluated. RESULTS: Statistical analyses showed excellent interscan, intraobserver, and interobserver agreement. All ICCs were greater than 0.75, P < 0.01 indicating excellent agreement between measurements. CONCLUSION: Experimental results show good interscan and excellent intra- and interobserver reproducibility, suggesting that DCE-MRI could be used in preclinical settings as a read-out for novel therapeutic interventions for atherosclerosis. This preliminary work encourages investigating the reproducibility of DCE-MRI also in clinical settings, where it could be used for monitoring high-risk patients and in longitudinal clinical drug trials. (c) 2010 Wiley-Liss, Inc.
PURPOSE: To investigate the short-term reproducibility of black-blood dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) in atherosclerotic rabbits to evaluate the potential of this technique to be a reliable readout of plaque progression and/or regression upon therapeutic intervention. MATERIALS AND METHODS:Atherosclerotic rabbits were imaged at baseline and 24 hours later with DCE-MRI on a 1.5T MRI system. DCE-MRI images were analyzed by calculating the area under the signal intensity versus time curve (AUC). Intraclass correlation coefficients (ICCs) were used to evaluate interscan, intraobserver, and interobserver reproducibility. In addition, the test-retest coefficient of variation (CoV) was evaluated. RESULTS: Statistical analyses showed excellent interscan, intraobserver, and interobserver agreement. All ICCs were greater than 0.75, P < 0.01 indicating excellent agreement between measurements. CONCLUSION: Experimental results show good interscan and excellent intra- and interobserver reproducibility, suggesting that DCE-MRI could be used in preclinical settings as a read-out for novel therapeutic interventions for atherosclerosis. This preliminary work encourages investigating the reproducibility of DCE-MRI also in clinical settings, where it could be used for monitoring high-risk patients and in longitudinal clinical drug trials. (c) 2010 Wiley-Liss, Inc.
Authors: Tobias Saam; Thomas S Hatsukami; Vasily L Yarnykh; Cecil E Hayes; Hunter Underhill; Baocheng Chu; Norihide Takaya; Jianming Cai; William S Kerwin; Dongxiang Xu; Nayak L Polissar; B Neradilek; Wendy K Hamar; Jeffrey Maki; Dennis W Shaw; Robert J Buck; Brad Wyman; Chun Yuan Journal: J Magn Reson Imaging Date: 2007-08 Impact factor: 4.813
Authors: William S Kerwin; Kevin D O'Brien; Marina S Ferguson; Nayak Polissar; Thomas S Hatsukami; Chun Yuan Journal: Radiology Date: 2006-09-11 Impact factor: 11.105
Authors: Susan M Galbraith; Martin A Lodge; N Jane Taylor; Gordon J S Rustin; Søren Bentzen; J James Stirling; Anwar R Padhani Journal: NMR Biomed Date: 2002-04 Impact factor: 4.044
Authors: James H F Rudd; Kelly S Myers; Sameer Bansilal; Josef Machac; Ash Rafique; Michael Farkouh; Valentin Fuster; Zahi A Fayad Journal: J Am Coll Cardiol Date: 2007-08-13 Impact factor: 24.094
Authors: James H F Rudd; Kelly S Myers; Sameer Bansilal; Josef Machac; Cathy Anne Pinto; Christopher Tong; Ash Rafique; Richard Hargeaves; Michael Farkouh; Valentin Fuster; Zahi A Fayad Journal: J Nucl Med Date: 2008-05-15 Impact factor: 10.057
Authors: Mark E Lobatto; Claudia Calcagno; Josbert M Metselaar; Gert Storm; Erik S G Stroes; Zahi A Fayad; Willem J M Mulder Journal: Methods Enzymol Date: 2012 Impact factor: 1.600
Authors: Claudia Calcagno; Mark E Lobatto; Hadrien Dyvorne; Philip M Robson; Antoine Millon; Max L Senders; Olivier Lairez; Sarayu Ramachandran; Bram F Coolen; Alexandra Black; Willem J M Mulder; Zahi A Fayad Journal: NMR Biomed Date: 2015-08-30 Impact factor: 4.044
Authors: Jason Mendes; Dennis L Parker; Scott McNally; Ed DiBella; Bradley D Bolster; Gerald S Treiman Journal: Magn Reson Med Date: 2013-12-24 Impact factor: 4.668
Authors: Claudia Calcagno; Sarayu Ramachandran; David Izquierdo-Garcia; Venkatesh Mani; Antoine Millon; David Rosenbaum; Ahmed Tawakol; Mark Woodward; Jan Bucerius; Erin Moshier; James Godbold; David Kallend; Michael E Farkouh; Valentin Fuster; James H F Rudd; Zahi A Fayad Journal: Eur J Nucl Med Mol Imaging Date: 2013-08-14 Impact factor: 9.236
Authors: Esad Vucic; Claudia Calcagno; Stephen D Dickson; James H F Rudd; Katsumi Hayashi; Jan Bucerius; Erin Moshier; Jessica S Mounessa; Michelle Roytman; Matthew J Moon; James Lin; Sarayu Ramachandran; Tatsuo Tanimoto; Karen Brown; Masakatsu Kotsuma; Sotirios Tsimikas; Edward A Fisher; Klaas Nicolay; Valentin Fuster; Zahi A Fayad Journal: JACC Cardiovasc Imaging Date: 2012-08