Literature DB >> 20576461

A study to explore the reliability and precision of intra and inter-rater measures of ULNT1 on an asymptomatic population.

George S Oliver1, Alison Rushton.   

Abstract

Upper Limb Neurodynamic Test 1 (ULNT1) is commonly used within clinical practice. However, the existing evidence regarding its reliability is conflicting and raises methodological questions. Therefore, the aim of this study was to investigate how reliable and precise physiotherapists are at recording both intra and inter-rater measurements of ULNT1 on an asymptomatic population. Forty asymptomatic subjects, 29 females and 11 males (18-42 years, mean 23.35), were recruited into this intra (stability) and inter-rater (equivalence) reliability and precision study. ULNT1 was recorded twice using an electrogoniometer by two experienced physiotherapists using a standardised operational description in conditions replicating clinical practice. Reliability was analysed using the Intraclass Correlation Coefficient (ICC₂,₁), and precision using Standard Error of Measurement (SEM) and Smallest Detectable Difference (SDD). The findings demonstrated excellent intra-rater (ICC₂,₁ 0.98 Rater 1; ICC₂,₁) 0.96 Rater 2) and good inter-rater (ICC₂,₁ 0.80) reliability. Precision was acceptable for both intra-rater (SEM 2.59° Rater 1; SEM 0.97° Rater 2; SDD 7.16° Rater 1; SDD 2.68° Rater 2), and inter-rater (SEM 3.83°; SDD 10.58°) measurements. These findings demonstrate that physiotherapists can use ULNT1 reliably and with precision for intra and inter-rater measurements of asymptomatic subjects in conditions that replicate clinical practice. The reproduction of this study on a population of symptomatic subjects is now warranted.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20576461     DOI: 10.1016/j.math.2010.05.009

Source DB:  PubMed          Journal:  Man Ther        ISSN: 1356-689X


  6 in total

1.  Agreement and Reliability of Median Neurodynamic Test 1 and Resting Scapular Position.

Authors:  Sean P Riley; Jason K Grimes; Kylie Calandra; Kelsey Foster; Melissa Peet; Matthew T Walsh
Journal:  J Chiropr Med       Date:  2021-01-22

2.  Upper Limb Neurodynamic Test 1 on Healthy Individuals: Intra- and Intersession Reliability of the Angle between Pain Onset and Submaximal Pain.

Authors:  Diego Leoni; Davide Storer; Roberto Gatti; Michele Egloff; Marco Barbero
Journal:  Pain Res Manag       Date:  2016-09-22       Impact factor: 3.037

3.  Side-to-side elbow range of movement variability in an ulnar neurodynamic test sequence variant in asymptomatic people.

Authors:  Michelle Meng Yim Tong; Vincent Cheng-Hsin Liu; Toby Hall
Journal:  Hong Kong Physiother J       Date:  2018-08-14

4.  Neurodynamic Functions and Their Correlations with Postural Parameters in Adolescents with Idiopathic Scoliosis.

Authors:  Agnieszka Stępień; Beata Pałdyna
Journal:  J Clin Med       Date:  2022-02-19       Impact factor: 4.241

5.  Fine adaptive precision grip control without maximum pinch strength changes after upper limb neurodynamic mobilization.

Authors:  Frédéric Dierick; Jean-Michel Brismée; Olivier White; Anne-France Bouché; Céline Périchon; Nastasia Filoni; Vincent Barvaux; Fabien Buisseret
Journal:  Sci Rep       Date:  2021-07-07       Impact factor: 4.379

6.  Relationship between Neuromuscular Mechanosensitivity and Chronic Neck Pain in Guitarists: A Cross-Sectional Study.

Authors:  Valeria Estefanía Aguilar Rojas; Arisandy Flores Pluma; Daniel Pecos-Martín; Alexander Achalandabaso-Ochoa; Rubén Fernández-Matías; Patricia Martinez-Merinero; Susana Nuñez-Nagy; Tomás Gallego-Izquierdo
Journal:  Int J Environ Res Public Health       Date:  2021-03-06       Impact factor: 3.390

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.