Literature DB >> 20576253

Transvaginal sonographic cervical length for the prediction of spontaneous preterm birth in twin pregnancies: a systematic review and metaanalysis.

Agustín Conde-Agudelo1, Roberto Romero, Sonia S Hassan, Lami Yeo.   

Abstract

OBJECTIVE: To assess the accuracy of transvaginal sonographic cervical length (CL) in predicting spontaneous preterm birth in women with twin pregnancies. STUDY
DESIGN: Systematic review and metaanalysis of predictive test accuracy.
RESULTS: Twenty-one studies (16 in asymptomatic women and 5 in symptomatic women) with a total of 3523 women met the inclusion criteria. Among asymptomatic women, a CL <or=20 mm at 20-24 weeks' gestation was the most accurate in predicting preterm birth <32 and <34 weeks' gestation (pooled sensitivities, specificities, and positive and negative likelihood ratios of 39% and 29%, 96% and 97%, 10.1 and 9.0, and 0.64 and 0.74, respectively). A CL <or=25 mm at 20-24 weeks' gestation had a pooled positive likelihood ratio of 9.6 to predict preterm birth <28 weeks' gestation. The predictive accuracy of CL for preterm birth was low in symptomatic women.
CONCLUSION: Transvaginal sonographic CL at 20-24 weeks' gestation is a good predictor of spontaneous preterm birth in asymptomatic women with twin pregnancies. Copyright (c) 2010. Published by Mosby, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20576253      PMCID: PMC3147231          DOI: 10.1016/j.ajog.2010.02.064

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  41 in total

1.  Exploring sources of heterogeneity in systematic reviews of diagnostic tests.

Authors:  Jeroen G Lijmer; Patrick M M Bossuyt; Siem H Heisterkamp
Journal:  Stat Med       Date:  2002-06-15       Impact factor: 2.373

Review 2.  Sources of variation and bias in studies of diagnostic accuracy: a systematic review.

Authors:  Penny Whiting; Anne W S Rutjes; Johannes B Reitsma; Afina S Glas; Patrick M M Bossuyt; Jos Kleijnen
Journal:  Ann Intern Med       Date:  2004-02-03       Impact factor: 25.391

Review 3.  Measuring inconsistency in meta-analyses.

Authors:  Julian P T Higgins; Simon G Thompson; Jonathan J Deeks; Douglas G Altman
Journal:  BMJ       Date:  2003-09-06

4.  Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data.

Authors:  S D Walter
Journal:  Stat Med       Date:  2002-05-15       Impact factor: 2.373

5.  Prediction of preterm delivery in twin pregnancy: a prospective, observational study of cervical length and fetal fibronectin testing.

Authors:  J L Gibson; L M Macara; P Owen; D Young; J Macauley; F Mackenzie
Journal:  Ultrasound Obstet Gynecol       Date:  2004-06       Impact factor: 7.299

Review 6.  Accuracy of cervical transvaginal sonography in predicting preterm birth: a systematic review.

Authors:  H Honest; L M Bachmann; A Coomarasamy; J K Gupta; J Kleijnen; K S Khan
Journal:  Ultrasound Obstet Gynecol       Date:  2003-09       Impact factor: 7.299

7.  Users' guides to the medical literature. III. How to use an article about a diagnostic test. B. What are the results and will they help me in caring for my patients? The Evidence-Based Medicine Working Group.

Authors:  R Jaeschke; G H Guyatt; D L Sackett
Journal:  JAMA       Date:  1994-03-02       Impact factor: 56.272

8.  Sonographic measurement of cervical length in twin pregnancies in threatened preterm labor.

Authors:  I Fuchs; E Tsoi; W Henrich; J W Dudenhausen; K H Nicolaides
Journal:  Ultrasound Obstet Gynecol       Date:  2004-01       Impact factor: 7.299

9.  [Ultrasonographic measurement of cervical length in twin pregnancies with preterm labor: comparison with singleton pregnancies].

Authors:  N Gonzalez; V Bige; S Kandoussi; O Graesslin; C Quereux; R Gabriel
Journal:  Gynecol Obstet Fertil       Date:  2004-02

10.  The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews.

Authors:  Penny Whiting; Anne W S Rutjes; Johannes B Reitsma; Patrick M M Bossuyt; Jos Kleijnen
Journal:  BMC Med Res Methodol       Date:  2003-11-10       Impact factor: 4.615

View more
  34 in total

1.  Guidelines for scanning twins and triplets with US and MRI.

Authors:  Maria A Calvo-Garcia
Journal:  Pediatr Radiol       Date:  2016-01-29

2.  The clinical significance of a positive Amnisure test in women with preterm labor and intact membranes.

Authors:  Seung Mi Lee; Roberto Romero; Jeong Woo Park; Sun Min Kim; Chan-Wook Park; Steven J Korzeniewski; Tinnakorn Chaiworapongsa; Bo Hyun Yoon
Journal:  J Matern Fetal Neonatal Med       Date:  2012-04-25

Review 3.  Vaginal progesterone in women with an asymptomatic sonographic short cervix in the midtrimester decreases preterm delivery and neonatal morbidity: a systematic review and metaanalysis of individual patient data.

Authors:  Roberto Romero; Kypros Nicolaides; Agustin Conde-Agudelo; Ann Tabor; John M O'Brien; Elcin Cetingoz; Eduardo Da Fonseca; George W Creasy; Katharina Klein; Line Rode; Priya Soma-Pillay; Shalini Fusey; Cetin Cam; Zarko Alfirevic; Sonia S Hassan
Journal:  Am J Obstet Gynecol       Date:  2011-12-11       Impact factor: 8.661

4.  Prevention and Therapy of Preterm Birth. Guideline of the DGGG, OEGGG and SGGG (S2k Level, AWMF Registry Number 015/025, February 2019) - Part 1 with Recommendations on the Epidemiology, Etiology, Prediction, Primary and Secondary Prevention of Preterm Birth.

Authors:  Richard Berger; Harald Abele; Franz Bahlmann; Ivonne Bedei; Klaus Doubek; Ursula Felderhoff-Müser; Herbert Fluhr; Yves Garnier; Susanne Grylka-Baeschlin; Hanns Helmer; Egbert Herting; Markus Hoopmann; Irene Hösli; Udo Hoyme; Alexandra Jendreizeck; Harald Krentel; Ruben Kuon; Wolf Lütje; Silke Mader; Holger Maul; Werner Mendling; Barbara Mitschdörfer; Tatjana Nicin; Monika Nothacker; Dirk Olbertz; Werner Rath; Claudia Roll; Dietmar Schlembach; Ekkehard Schleußner; Florian Schütz; Vanadin Seifert-Klauss; Susanne Steppat; Daniel Surbek
Journal:  Geburtshilfe Frauenheilkd       Date:  2019-08-12       Impact factor: 2.915

Review 5.  Ultrasound surveillance in twin pregnancy: An update for practitioners.

Authors:  R Townsend; A Khalil
Journal:  Ultrasound       Date:  2018-08-22

6.  Progesterone to prevent preterm birth in twin gestations: what is the next step forward?

Authors:  R Romero
Journal:  BJOG       Date:  2013-01       Impact factor: 6.531

Review 7.  Predictive accuracy of changes in transvaginal sonographic cervical length over time for preterm birth: a systematic review and metaanalysis.

Authors:  Agustin Conde-Agudelo; Roberto Romero
Journal:  Am J Obstet Gynecol       Date:  2015-06-10       Impact factor: 8.661

Review 8.  A blueprint for the prevention of preterm birth: vaginal progesterone in women with a short cervix.

Authors:  Roberto Romero; Lami Yeo; Jezid Miranda; Sonia S Hassan; Agustin Conde-Agudelo; Tinnakorn Chaiworapongsa
Journal:  J Perinat Med       Date:  2013-01       Impact factor: 1.901

9.  Serial cervical length determination in twin pregnancies reveals 4 distinct patterns with prognostic significance for preterm birth.

Authors:  Nir Melamed; Alex Pittini; Liran Hiersch; Yariv Yogev; Steven S Korzeniewski; Roberto Romero; Jon Barrett
Journal:  Am J Obstet Gynecol       Date:  2016-05-17       Impact factor: 8.661

10.  Do serial measurements of cervical length improve the prediction of preterm birth in asymptomatic women with twin gestations?

Authors:  Nir Melamed; Alex Pittini; Liran Hiersch; Yariv Yogev; Steven J Korzeniewski; Roberto Romero; Jon Barrett
Journal:  Am J Obstet Gynecol       Date:  2016-06-27       Impact factor: 8.661

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.