Literature DB >> 20574087

Diagnostic accuracy of multidetector CT in acute mesenteric ischemia: systematic review and meta-analysis.

Jan Menke1.   

Abstract

PURPOSE: To use meta-analysis to determine the diagnostic accuracy of contrast agent-enhanced multidetector computed tomography (CT) in primary acute mesenteric ischemia (AMI).
MATERIALS AND METHODS: The PubMed search engine and five other electronic databases were searched for "mesenteric ischemia," "computed tomography," and related terms in articles published between January 1996 and September 2009, without language restrictions. Reference lists of retrieved articles were also searched. Two reviewers independently selected six studies that reported 2 x 2 contingency data on the diagnostic accuracy of multidetector CT in primary AMI in at least 10 patients with disease and 10 patients without disease and that used surgery or clinical outcome as the reference standard. Study data were independently extracted by the two reviewers, and disagreement was resolved by consensus. The study quality was assessed by using items from the Quality Assessment of Diagnostic Accuracy Studies tool. The primary 2 x 2 count data were investigated with a bivariate random-effects meta-analysis of sensitivity and specificity.
RESULTS: Three studies were prospective, and three were retrospective. All studies were of high quality. The CT scanners used in the included studies had between four and 40 rows. The between-study heterogeneity was low to moderate. Overall, AMI was found in 142 of 619 studied cases. The meta-analysis showed a pooled sensitivity of 93.3% (95% confidence interval: 82.8%, 97.6%) and a pooled specificity of 95.9% (95% confidence interval: 91.2%, 98.2%).
CONCLUSION: On the basis of a thorough clinical examination, contrast-enhanced multidetector CT allows the diagnosis of primary AMI with high sensitivity and specificity. Thus, it may be used as the first-line imaging method.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20574087     DOI: 10.1148/radiol.10091938

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  60 in total

1.  Laparoscopic approach to acute abdomen from the Consensus Development Conference of the Società Italiana di Chirurgia Endoscopica e nuove tecnologie (SICE), Associazione Chirurghi Ospedalieri Italiani (ACOI), Società Italiana di Chirurgia (SIC), Società Italiana di Chirurgia d'Urgenza e del Trauma (SICUT), Società Italiana di Chirurgia nell'Ospedalità Privata (SICOP), and the European Association for Endoscopic Surgery (EAES).

Authors:  Ferdinando Agresta; Luca Ansaloni; Gian Luca Baiocchi; Carlo Bergamini; Fabio Cesare Campanile; Michele Carlucci; Giafranco Cocorullo; Alessio Corradi; Boris Franzato; Massimo Lupo; Vincenzo Mandalà; Antonino Mirabella; Graziano Pernazza; Micaela Piccoli; Carlo Staudacher; Nereo Vettoretto; Mauro Zago; Emanuele Lettieri; Anna Levati; Domenico Pietrini; Mariano Scaglione; Salvatore De Masi; Giuseppe De Placido; Marsilio Francucci; Monica Rasi; Abe Fingerhut; Selman Uranüs; Silvio Garattini
Journal:  Surg Endosc       Date:  2012-06-27       Impact factor: 4.584

Review 2.  Multidetector CT imaging in mesenteric ischemia--pearls and pitfalls.

Authors:  Ashish Wasnik; Ravi K Kaza; Mahmoud M Al-Hawary; Peter S Liu; Joel F Platt
Journal:  Emerg Radiol       Date:  2010-12-04

3.  The impact of early diagnostic laparoscopy on the prognosis of patients with suspected acute mesenteric ischemia.

Authors:  M Gonenc; C A Dural; A Kocatas; S Buyukasik; M Karabulut; H Alis
Journal:  Eur J Trauma Emerg Surg       Date:  2013-01-22       Impact factor: 3.693

Review 4.  Multidetector CT in emergency radiology: acute and generalized non-traumatic abdominal pain.

Authors:  Pasquale Paolantonio; Marco Rengo; Riccardo Ferrari; Andrea Laghi
Journal:  Br J Radiol       Date:  2016-01-22       Impact factor: 3.039

5.  Neutrophil-to-lymphocyte ratio as a diagnostic biomarker for the diagnosis of acute mesenteric ischemia.

Authors:  R Aktimur; S Cetinkunar; K Yildirim; S H Aktimur; M Ugurlucan; N Ozlem
Journal:  Eur J Trauma Emerg Surg       Date:  2015-06-10       Impact factor: 3.693

6.  ACG clinical guideline: epidemiology, risk factors, patterns of presentation, diagnosis, and management of colon ischemia (CI).

Authors:  Lawrence J Brandt; Paul Feuerstadt; George F Longstreth; Scott J Boley
Journal:  Am J Gastroenterol       Date:  2014-12-23       Impact factor: 10.864

7.  Prognostic factors in patients with acute mesenteric ischemia.

Authors:  Doğan Yıldırım; Adnan Hut; Cihad Tatar; Turgut Dönmez; Muzaffer Akıncı; Mehmet Toptaş
Journal:  Turk J Surg       Date:  2017-06-01

8.  Imaging of acute superior mesenteric artery embolus using spectral CT in a canine model.

Authors:  Hongzhen Wang; Xigang Xiao; Wei Zhang; Zhiwen Ma; Jin Ling Zhang; Liang Tang; Xiuhua Yang
Journal:  Br J Radiol       Date:  2015-07-17       Impact factor: 3.039

9.  The value of serial serum lactate measurements in predicting the extent of ischemic bowel and outcome of patients suffering acute mesenteric ischemia.

Authors:  Peter Studer; Adrian Vaucher; Daniel Candinas; Beat Schnüriger
Journal:  J Gastrointest Surg       Date:  2015-01-30       Impact factor: 3.452

10.  Challenges in diagnosing mesenteric ischemia.

Authors:  Teun C van den Heijkant; Bart A C Aerts; Joep A Teijink; Wim A Buurman; Misha D P Luyer
Journal:  World J Gastroenterol       Date:  2013-03-07       Impact factor: 5.742

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.