Literature DB >> 20573539

Interventional 4D motion estimation and reconstruction of cardiac vasculature without motion periodicity assumption.

C Rohkohl1, G Lauritsch, L Biller, M Prümmer, J Boese, J Hornegger.   

Abstract

Anatomical and functional information of cardiac vasculature is a key component in the field of interventional cardiology. With the technology of C-arm CT it is possible to reconstruct static intraprocedural 3D images from angiographic projection data. Current approaches attempt to add the temporal dimension (4D). In the assumption of periodic heart motion, ECG-gating techniques can be used. However, arrhythmic heart signals and slight breathing motion are degrading image quality frequently. To overcome those problems, we present a reconstruction method based on a 4D time-continuous B-spline motion field. The temporal component of the motion field is parameterized by the acquisition time and does not assume a periodic heart motion. The analytic dynamic FDK-reconstruction formula is used directly for the motion estimation and image reconstruction. In a physical phantom experiment two vessels of size 3.1mm and 2.3mm were reconstructed using the proposed method and an algorithm with periodicity assumption. For a periodic motion both methods obtained an error of 0.1mm. For a non-periodic motion the proposed method was superior, obtaining an error of 0.3mm/0.2mm in comparison to 1.2mm/1.0mm for the algorithm with periodicity assumption. For a clinical test case of a left coronary artery it could be further shown that the method is capable to produce diameter measurements with an absolute error of 0.1mm compared to state-of-the-art measurement tools from orthogonal coronary angiography. Further, it is shown for three different clinical cases (left/right coronary artery, coronary sinus) that the proposed method is able to handle a large variability of vascular structures and motion patterns. The complete algorithm is hardware-accelerated using the GPU requiring a computation time of less than 3min for typical clinical scenarios. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20573539     DOI: 10.1016/j.media.2010.05.003

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  4 in total

1.  Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. Part I. Numerical model-based optimization.

Authors:  Jang-Hwan Choi; Rebecca Fahrig; Andreas Keil; Thor F Besier; Saikat Pal; Emily J McWalter; Gary S Beaupré; Andreas Maier
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

2.  Local motion-compensated method for high-quality 3D coronary artery reconstruction.

Authors:  Bo Liu; Xiangzhi Bai; Fugen Zhou
Journal:  Biomed Opt Express       Date:  2016-11-23       Impact factor: 3.732

3.  Evaluation of interpolation methods for surface-based motion compensated tomographic reconstruction for cardiac angiographic C-arm data.

Authors:  Kerstin Müller; Chris Schwemmer; Joachim Hornegger; Yefeng Zheng; Yang Wang; Günter Lauritsch; Christopher Rohkohl; Andreas K Maier; Carl Schultz; Rebecca Fahrig
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

4.  Reference-free learning-based similarity metric for motion compensation in cone-beam CT.

Authors:  H Huang; J H Siewerdsen; W Zbijewski; C R Weiss; M Unberath; T Ehtiati; A Sisniega
Journal:  Phys Med Biol       Date:  2022-06-16       Impact factor: 4.174

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.