Literature DB >> 20570104

Dissociation of polyethylene insert from the tibial baseplate following revision total knee arthroplasty.

Chin-En Chen1, Rei-Jahn Juhn, Jih-Yang Ko.   

Abstract

Dissociation of a modular tibial insert from the metal baseplate is a rare complication after revision total knee arthroplasty. We herein report an unusual presentation of a polyethylene insert failure that occurred in a posterior-stabilized constrained total knee arthroplasty. The polyethylene insert was posteriorly displaced, which has never been reported in the literature. The assumed mechanism is disengagement of the locking screw after repetitive motion. During knee full extension while standing from a chair, a sudden downward force on the anterior half of the insert caused posterior lift-off of the insert from the tibial baseplate and promoted a sliding force to push the insert posterior when the locking mechanism failed. This unique complication in a fully constrained posterior-stabilized implant should be considered as a cause for implant failure.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20570104     DOI: 10.1016/j.arth.2010.04.016

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Failure of tibial polyethylene insert locking mechanism in posterior stabilized arthroplasty.

Authors:  Emmanuel Thienpont
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-01       Impact factor: 4.342

2.  [Spin out - an avoidable complication in total knee replacement].

Authors:  M N Magin
Journal:  Orthopade       Date:  2014-02       Impact factor: 1.087

3.  Disengagement of tibial insert locking pin in total knee arthroplasty - A rare failure case report.

Authors:  Sanjeev Jindal; Vivek Bansal; Mannan Ahmed
Journal:  J Clin Orthop Trauma       Date:  2022-08-21

4.  Ten-Year Results of Primary and Revision Condylar-Constrained Total Knee Arthroplasty in Patients with Severe Coronal Plane Instability.

Authors:  Andrea Camera; Stefano Biggi; Gabriele Cattaneo; Giovanni Brusaferri
Journal:  Open Orthop J       Date:  2015-08-31

5.  Failure of Polyethelene Insert Locking Mechanism after a Posterior Stabilised Total Knee Arthroplasty- A Case Report.

Authors:  Gurava Reddy Ay; Soundar Rajan D; Chiranjeevi T; Karthik C; Krishna Kiran E
Journal:  J Orthop Case Rep       Date:  2016 Jul-Aug

6.  Knee Implant Dislocation Leading to Major Amputation 13 Years Later.

Authors:  Salomé Kuntz; Anne Lejay; Renu Virmani; Nabil Chakfé
Journal:  EJVES Short Rep       Date:  2019-05-23

7.  Spontaneous dislocation of the polyethylene component following knee revision arthroplasty: case report.

Authors:  Eduardo Zaniol Migon; Geraldo Luiz Schuck de Freitas; Marcos Wainberg Rodrigues; Gustavo Kaempf de Oliveira; Luis Gustavo Morato Pinto de Almeida; Carlos Roberto Schwartsmann
Journal:  Rev Bras Ortop       Date:  2014-12-29
  7 in total