Literature DB >> 20567085

Fast-scanning high-flux microprobe for biological X-ray fluorescence microscopy and microXAS.

R A Barrea1, D Gore, N Kujala, C Karanfil, S Kozyrenko, R Heurich, M Vukonich, R Huang, T Paunesku, G Woloschak, T C Irving.   

Abstract

There is a growing interest in the biomedical community in obtaining information concerning the distribution and local chemical environment of metals in tissues and cells. Recently, biological X-ray fluorescence microscopy (XFM) has emerged as the tool of choice to address these questions. A fast-scanning high-flux X-ray microprobe, built around a recently commissioned pair of 200 mm-long Rh-coated silicon Kirkpatrick-Baez mirrors, has been constructed at BioCAT beamline 18ID at the Advanced Photon Source. The new optical system delivers a flux of 1.3 x 10(12) photons s(-1) into a minimum focal spot size of approximately 3-5 microm FWHM. A set of Si drift detectors and bent Laue crystal analyzers may be used in combination with standard ionization chambers for X-ray fluorescence measurements. BioCAT's scanning software allows fast continuous scans to be performed while acquiring and storing full multichannel analyzer spectra per pixel on-the-fly with minimal overhead time (<20 ms per pixel). Together, the high-flux X-ray microbeam and the rapid-scanning capabilities of the BioCAT beamline allow the collection of XFM and micro X-ray absorption spectroscopy (microXAS) measurements from as many as 48 tissue sections per day. This paper reports the commissioning results of the new instrument with representative XFM and microXAS results from tissue samples.

Entities:  

Mesh:

Year:  2010        PMID: 20567085      PMCID: PMC2891492          DOI: 10.1107/S0909049510016869

Source DB:  PubMed          Journal:  J Synchrotron Radiat        ISSN: 0909-0495            Impact factor:   2.616


  15 in total

1.  A bent Laue analyzer for fluorescence EXAFS detection.

Authors:  Z Zhong; D Chapman; B Bunker; G Bunker; R Fischetti; C Segre
Journal:  J Synchrotron Radiat       Date:  1999-05-01       Impact factor: 2.616

2.  The BioCAT undulator beamline 18ID: a facility for biological non-crystalline diffraction and X-ray absorption spectroscopy at the Advanced Photon Source.

Authors:  R Fischetti; S Stepanov; G Rosenbaum; R Barrea; E Black; D Gore; R Heurich; E Kondrashkina; A J Kropf; S Wang; Ke Zhang; T C Irving; G B Bunker
Journal:  J Synchrotron Radiat       Date:  2004-08-17       Impact factor: 2.616

3.  Beamline 10.3.2 at ALS: a hard X-ray microprobe for environmental and materials sciences.

Authors:  Matthew A Marcus; Alastair A MacDowell; Richard Celestre; Alain Manceau; Tom Miller; Howard A Padmore; Robert E Sublett
Journal:  J Synchrotron Radiat       Date:  2004-04-21       Impact factor: 2.616

4.  ATHENA, ARTEMIS, HEPHAESTUS: data analysis for X-ray absorption spectroscopy using IFEFFIT.

Authors:  B Ravel; M Newville
Journal:  J Synchrotron Radiat       Date:  2005-06-15       Impact factor: 2.616

Review 5.  X-ray fluorescence microprobe imaging in biology and medicine.

Authors:  Tatjana Paunesku; Stefan Vogt; Jörg Maser; Barry Lai; Gayle Woloschak
Journal:  J Cell Biochem       Date:  2006-12-15       Impact factor: 4.429

6.  High-energy x-ray microbeam with total-reflection mirror optics.

Authors:  Yoshio Suzuki; Akihisa Takeuchi; Yasuko Terada
Journal:  Rev Sci Instrum       Date:  2007-05       Impact factor: 1.523

7.  Biological applications of X-ray microprobes.

Authors:  Tatjana Paunesku; Stefan Vogt; Thomas C Irving; Barry Lai; Raul A Barrea; Jörg Maser; Gayle E Woloschak
Journal:  Int J Radiat Biol       Date:  2009-08       Impact factor: 2.694

8.  Disturbed homeostasis of zinc and other essential elements in the prostate gland dependent on the character of pathological lesions.

Authors:  Andrzej Sapota; Adam Darago; Jan Taczalski; Anna Kilanowicz
Journal:  Biometals       Date:  2009-12       Impact factor: 2.949

9.  Synchrotron X-ray imaging reveals a correlation of tumor copper speciation with Clioquinol's anticancer activity.

Authors:  Raul A Barrea; Di Chen; Thomas C Irving; Q Ping Dou
Journal:  J Cell Biochem       Date:  2009-09-01       Impact factor: 4.429

Review 10.  Zinc and prostatic cancer.

Authors:  Emily Ho; Yang Song
Journal:  Curr Opin Clin Nutr Metab Care       Date:  2009-11       Impact factor: 4.294

View more
  10 in total

1.  Quantitative performance measurements of bent crystal Laue analyzers for X-ray fluorescence spectroscopy.

Authors:  C Karanfil; G Bunker; M Newville; C U Segre; D Chapman
Journal:  J Synchrotron Radiat       Date:  2012-03-17       Impact factor: 2.616

2.  X-ray fluorescence imaging of the hippocampal formation after manganese exposure.

Authors:  Gregory Robison; Taisiya Zakharova; Sherleen Fu; Wendy Jiang; Rachael Fulper; Raul Barrea; Wei Zheng; Yulia Pushkar
Journal:  Metallomics       Date:  2013-11       Impact factor: 4.526

3.  X-ray micro-diffraction studies on biological samples at the BioCAT Beamline 18-ID at the Advanced Photon Source.

Authors:  R A Barrea; O Antipova; D Gore; R Heurich; M Vukonich; N G Kujala; T C Irving; J P R O Orgel
Journal:  J Synchrotron Radiat       Date:  2014-08-08       Impact factor: 2.616

4.  Increased brain iron coincides with early plaque formation in a mouse model of Alzheimer's disease.

Authors:  Andreana C Leskovjan; Ariane Kretlow; Antonio Lanzirotti; Raul Barrea; Stefan Vogt; Lisa M Miller
Journal:  Neuroimage       Date:  2010-11-30       Impact factor: 6.556

5.  High resolution short focal distance Bent Crystal Laue Analyzer for copper K edge x-ray absorption spectroscopy.

Authors:  N G Kujala; C Karanfil; R A Barrea
Journal:  Rev Sci Instrum       Date:  2011-06       Impact factor: 1.523

6.  Use of X-Ray Fluorescence Microscopy for Studies on Research Models of Hepatocellular Carcinoma.

Authors:  Tatjana Paunesku; Andrew C Gordon; Sarah White; Kathleen Harris; Olga Antipova; Evan Maxey; Stefan Vogt; Anthony Smith; Luiza Daddario; Daniele Procissi; Andrew Larson; Gayle E Woloschak
Journal:  Front Public Health       Date:  2021-08-20

7.  3D imaging of transition metals in the zebrafish embryo by X-ray fluorescence microtomography.

Authors:  Daisy Bourassa; Sophie-Charlotte Gleber; Stefan Vogt; Hong Yi; Fabian Will; Heiko Richter; Chong Hyun Shin; Christoph J Fahrni
Journal:  Metallomics       Date:  2014-09       Impact factor: 4.526

Review 8.  X-ray fluorescence microscopy for investigation of archival tissues.

Authors:  T Paunesku; M B Wanzer; E N Kirillova; K N Muksinova; V S Revina; E R Lyubchansky; B Grosche; M Birschwilks; S Vogt; L Finney; G E Woloschak
Journal:  Health Phys       Date:  2012-08       Impact factor: 1.316

9.  Increased β-amyloid deposition in Tg-SWDI transgenic mouse brain following in vivo lead exposure.

Authors:  Huiying Gu; Gregory Robison; Lan Hong; Raul Barrea; Xing Wei; Martin R Farlow; Yulia N Pushkar; Yansheng Du; Wei Zheng
Journal:  Toxicol Lett       Date:  2012-07-11       Impact factor: 4.372

10.  Sub-millisecond time-resolved SAXS using a continuous-flow mixer and X-ray microbeam.

Authors:  Rita Graceffa; R Paul Nobrega; Raul A Barrea; Sagar V Kathuria; Srinivas Chakravarthy; Osman Bilsel; Thomas C Irving
Journal:  J Synchrotron Radiat       Date:  2013-10-01       Impact factor: 2.616

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.