Accuracy and reproducibility of a novel semi-automatic segmentation technique for MR volumetry of the pituitary gland.

Diane M Renz1, Horst K Hahn, Peter Schmidt, Jan Rexilius, Markus Lentschig, Alexander Pfeil, Dieter Sauner, Clemens Fitzek, Hans-Joachim Mentzel, Werner A Kaiser, Jürgen R Reichenbach, Joachim Böttcher.   

Abstract

INTRODUCTION: Although several reports about volumetric determination of the pituitary gland exist, volumetries have been solely performed by indirect measurements or manual tracing on the gland's boundaries. The purpose of this study was to evaluate the accuracy and reproducibility of a novel semi-automatic MR-based segmentation technique.
METHODS: In an initial technical investigation, T1-weighted 3D native magnetised prepared rapid gradient echo sequences (1.5 T) with 1 mm isotropic voxel size achieved high reliability and were utilised in different in vitro and in vivo studies. The computer-assisted segmentation technique was based on an interactive watershed transform after resampling and gradient computation. Volumetry was performed by three observers with different software and neuroradiologic experiences, evaluating phantoms of known volume (0.3, 0.9 and 1.62 ml) and healthy subjects (26 to 38 years; overall 135 volumetries).
RESULTS: High accuracy of the volumetry was shown by phantom analysis; measurement errors were <4% with a mean error of 2.2%. In vitro, reproducibility was also promising with intra-observer variability of 0.7% for observer 1 and 0.3% for observers 2 and 3; mean inter-observer variability was in vitro 1.2%. In vivo, scan-rescan, intra-observer and inter-observer variability showed mean values of 3.2%, 1.8% and 3.3%, respectively. Unifactorial analysis of variance demonstrated no significant differences between pituitary volumes for various MR scans or software calculations in the healthy study groups (p > 0.05).
CONCLUSION: The analysed semi-automatic MR volumetry of the pituitary gland is a valid, reliable and fast technique. Possible clinical applications are hyperplasia or atrophy of the gland in pathological circumstances either by a single assessment or by monitoring in follow-up studies.

Entities:  

Mesh:

Year:  2010        PMID: 20563571     DOI: 10.1007/s00234-010-0727-0

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  39 in total

1.  Partial volume effects in MRI studies of multiple sclerosis.

Authors:  M J Firbank; A Coulthard; R M Harrison; E D Williams
Journal:  Magn Reson Imaging       Date:  1999-05       Impact factor: 2.546

2.  Seasonality and pituitary volume.

Authors:  P J Schwartz; J A Loe; C N Bash; K Bove; E H Turner; J A Frank; T A Wehr; N E Rosenthal
Journal:  Psychiatry Res       Date:  1997-07-04       Impact factor: 3.222

3.  Magnetic resonance imaging of the normal pituitary gland using ultrashort TE (UTE) pulse sequences (REV 1.0).

Authors:  Olivia Portman; Stephen Flemming; Jeremy P D Cox; Desmond G Johnston; Graeme M Bydder
Journal:  Neuroradiology       Date:  2007-11-22       Impact factor: 2.804

4.  Estimation of pituitary gland dimensions from radiographs of the sella turcica. A post-mortem study.

Authors:  M S McLachlan; E D Williams; R W Fortt; F H Doyle
Journal:  Br J Radiol       Date:  1968-05       Impact factor: 3.039

5.  Pituitary adenomas and normal pituitary tissue: enhancement patterns on gadopentetate-enhanced MR imaging.

Authors:  Y Miki; M Matsuo; S Nishizawa; Y Kuroda; A Keyaki; Y Makita; J Kawamura
Journal:  Radiology       Date:  1990-10       Impact factor: 11.105

Review 6.  Update on the medical management of pituitary adenomas.

Authors:  Cheryl A Pickett
Journal:  Curr Neurol Neurosci Rep       Date:  2005-05       Impact factor: 5.081

7.  Rapid progression of pituitary hyperplasia in humans with primary hypothyroidism: demonstration with MR imaging.

Authors:  T Shimono; H Hatabu; K Kasagi; Y Miki; S Nishizawa; T Misaki; A Hiraga; J Konishi
Journal:  Radiology       Date:  1999-11       Impact factor: 11.105

8.  Temporal horn index and volume of medial temporal lobe atrophy using a new semiautomated method for rapid and precise assessment.

Authors:  F L Giesel; H K Hahn; P A Thomann; E Widjaja; E Wignall; H von Tengg-Kobligk; J Pantel; P D Griffiths; H O Peitgen; J Schroder; M Essig
Journal:  AJNR Am J Neuroradiol       Date:  2006-08       Impact factor: 3.825

Review 9.  Imaging of sellar and parasellar lesions.

Authors:  Janine Rennert; Arnd Doerfler
Journal:  Clin Neurol Neurosurg       Date:  2006-11-28       Impact factor: 1.876

10.  MR volumetry for monitoring intramuscular bromocriptine treatment in macroprolactinomas.

Authors:  H Benesch; S R Felber; G Finkenstedt; C Kremser; G Stockhammer; F T Aichner
Journal:  J Comput Assist Tomogr       Date:  1995 Nov-Dec       Impact factor: 1.826

View more
  2 in total

1.  Changes of pituitary gland volume in Kennedy disease.

Authors:  C C Pieper; I K Teismann; C Konrad; W L Heindel; H Schiffbauer
Journal:  AJNR Am J Neuroradiol       Date:  2013-06-06       Impact factor: 3.825

2.  Three-dimensional magnetic resonance volumetry of the pituitary gland is effective in detecting short stature in children.

Authors:  Xue Han; Jianjun Xiu; Zhaoqin Huang; Jie Zhang; Zhonghe Zhang; Yin Dong; Xianshun Yuan; Qingwei Liu
Journal:  Exp Ther Med       Date:  2014-06-11       Impact factor: 2.447

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.