Literature DB >> 20552085

A preliminary study on the short-term efficacy of chairside computer-aided design/computer-assisted manufacturing- generated posterior lithium disilicate crowns.

Sven Reich1, Sören Fischer, Bernhard Sobotta, Horst-Uwe Klapper, Stephan Gozdowski.   

Abstract

The purpose of this preliminary study was to evaluate the clinical performance of chairside-generated crowns over a preliminary time period of 24 months. Forty-one posterior crowns made of a machinable lithium disilicate ceramic for full-contour crowns were inserted in 34 patients using a chairside computer-aided design/computer-assisted manufacturing technique. The crowns were evaluated at baseline and after 6, 12, and 24 months according to modified United States Public Health Service criteria. After 2 years, all reexamined crowns (n = 39) were in situ; one abutment exhibited secondary caries and two abutments received root canal treatment. Within the limited observation period, the crowns revealed clinically satisfying results.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20552085

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  6 in total

1.  Reliability of reduced-thickness and thinly veneered lithium disilicate crowns.

Authors:  N R F A Silva; E A Bonfante; L M Martins; G B Valverde; V P Thompson; J L Ferencz; P G Coelho
Journal:  J Dent Res       Date:  2011-12-28       Impact factor: 6.116

2.  Monolithic and bi-layer CAD/CAM lithium-disilicate versus metal-ceramic fixed dental prostheses: comparison of fracture loads and failure modes after fatigue.

Authors:  Stefan Schultheis; Joerg R Strub; Thomas A Gerds; Petra C Guess
Journal:  Clin Oral Investig       Date:  2012-09-22       Impact factor: 3.573

3.  Chair-side generated posterior lithium disilicate crowns after 4 years.

Authors:  Sven Reich; Oliver Schierz
Journal:  Clin Oral Investig       Date:  2012-11-08       Impact factor: 3.573

4.  CO2 laser dentin surface treatment most effectively increased ceramic shear bond strength.

Authors:  Ahmed El Gamal; Etienne Medioni; Jean Paul Rocca; Carlo Fornaini; Nathalie Brulat-Bouchard
Journal:  Laser Ther       Date:  2018-03-31

Review 5.  Assessment of Chair-side Computer-Aided Design and Computer-Aided Manufacturing Restorations: A Review of the Literature.

Authors:  Kusai Baroudi; Shukran Nasser Ibraheem
Journal:  J Int Oral Health       Date:  2015-04

Review 6.  A systematic review of outcome measurements and quality of studies evaluating fixed tooth-supported restorations.

Authors:  Devangkumar Rajnikant Patel; Tim O'Brien; Aviva Petrie; Haralampos Petridis
Journal:  J Prosthodont       Date:  2014-06-19       Impact factor: 2.752

  6 in total