Literature DB >> 20548801

Right ventricle-sparing left ventricular resection and replacement with a continuous-flow rotary blood pump: an in vivo experiment.

O H Frazier1, Egemen Tuzun, Cuneyt Narin, William E Cohn.   

Abstract

Despite recent advances in left ventricular assist device and total artificial heart technologies, these devices are still so large that they pose a significant problem in small patients with refractory heart failure. Excising the left ventricle while preserving the right ventricle--and then replacing the left ventricle with a mechanical pump--has been proposed as an alternative approach to this problem. We conducted a pilot study to evaluate possible surgical techniques and the hemodynamic effects of right ventricle-sparing left ventricular resection and replacement with a continuous-flow rotary blood pump in a healthy bovine model.

Entities:  

Keywords:  Animals; blood pump, centrifugal; heart failure, congestive; heart transplantation; heart ventricles; heart, artificial; heart-assist devices; prosthesis fitting; prosthesis implantation

Mesh:

Year:  2010        PMID: 20548801      PMCID: PMC2879189     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  7 in total

1.  Surgical technique and hemodynamic characteristics of partial cardiac replacement with an artificial left ventricle.

Authors:  O H Frazier; R Colón; Y Taenaka
Journal:  Tex Heart Inst J       Date:  1986-09

2.  Total circulatory support with an LVAD in an adolescent with a previous Fontan procedure.

Authors:  O H Frazier; Igor D Gregoric; Gregory N Messner
Journal:  Tex Heart Inst J       Date:  2005

3.  In vivo evaluation of the HeartWare centrifugal ventricular assist device.

Authors:  Egemen Tuzun; Katy Roberts; William E Cohn; Murat Sargin; Courtney J Gemmato; Branislav Radovancevic; O H Frazier
Journal:  Tex Heart Inst J       Date:  2007

4.  Differences in pulsatile and non-pulsatile mechanical circulatory support in long-term use.

Authors:  Thorsten Drews; Michael Jurmann; Dandel Michael; Pasic Miralem; Yuguo Weng; Roland Hetzer
Journal:  J Heart Lung Transplant       Date:  2008-10       Impact factor: 10.247

5.  Replacement of the left ventricle with a single-chambered artificial pump.

Authors:  O H Frazier; R Colon; Y Taenaka; S Igo; J Fuqua
Journal:  J Heart Transplant       Date:  1986 Jul-Aug

6.  Reliable suction detection for patients with rotary blood pumps.

Authors:  David G Mason; Andrew K Hilton; Robert F Salamonsen
Journal:  ASAIO J       Date:  2008 Jul-Aug       Impact factor: 2.872

7.  The total artificial heart: where we stand.

Authors:  O H Frazier; Robert D Dowling; Laman A Gray; Nyma A Shah; Toni Pool; Igor Gregoric
Journal:  Cardiology       Date:  2004       Impact factor: 1.869

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.