Literature DB >> 20545776

Influence of the lubricant and the alloy on the wear behaviour of attachments.

Stefan Bayer1, Ludger Keilig, Dominik Kraus, Manfred Grüner, Helmut Stark, Sebastian Mues, Norbert Enkling.   

Abstract

OBJECTIVES: Wear of attachments leads to a loss of retention and reduces the function of overdentures. This study evaluated the retention force changes of an attachment system for overdentures. The influence of the lubricant and the alloy on wear constancy was examined.
METHODS: Cylindrical anchors of the Dalbo(®) -Z system were tested (Cendres+Métaux SA). Three groups of alloy-lubricant combinations were generated 1.Elitor(®) /NaCl-solution (EN) 2.Elitor(®) /Glandosane(®) aquadest. (EG) and 3.Valor(®) /Glandosane(®) /aquadest. (VG). Ten samples of each group were subjected to 10 000 insertion-separation cycles.
RESULTS: For the EN-group, this led to a large increase in retention force. The EG- and VG-group showed a constant decrease after an initial increase in retention force at the beginning of the wear simulation. The change of the alloy caused no statistically significant differences. The use of a more viscous lubricant reduced the retention force increase significantly.
CONCLUSIONS: The use of a lubricant which simulates clinical conditions is an absolute need for wear simulation because the retention force changes are influenced enormously. The change of the alloy at the Dalbo(®) -Z system did not influence the wear behaviour. As a slight decrease in retention force was recorded, it is useful for an attachment system to allow compensation with an adjustable matrix.
© 2010 The Gerodontology Society and John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20545776     DOI: 10.1111/j.1741-2358.2009.00352.x

Source DB:  PubMed          Journal:  Gerodontology        ISSN: 0734-0664            Impact factor:   2.980


  7 in total

1.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

2.  CAD/CAM milled removable complete dentures: an in vitro evaluation of trueness.

Authors:  Murali Srinivasan; Yoann Cantin; Albert Mehl; Harald Gjengedal; Frauke Müller; Martin Schimmel
Journal:  Clin Oral Investig       Date:  2016-11-08       Impact factor: 3.573

3.  In vitro retention force measurement for three different attachment systems for implant-retained overdenture.

Authors:  Kareem Mohammed Reda; Ibrahim Ramadan El-Torky; Mohamed Nabeel El-Gendy
Journal:  J Indian Prosthodont Soc       Date:  2016 Oct-Dec

4.  A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study.

Authors:  Namrata Agrawal; Sumeet Jain; Deepak Agrawal
Journal:  J Indian Prosthodont Soc       Date:  2018 Jan-Mar

5.  In Vitro Effects of Cyclic Dislodgement on Retentive Properties of Various Titanium-Based Dental Implant Overdentures Attachment System.

Authors:  Tae-Yun Kang; Jee-Hwan Kim; Kwang-Mahn Kim; Jae-Sung Kwon
Journal:  Materials (Basel)       Date:  2019-11-16       Impact factor: 3.623

6.  The Effect of Denture Cleansing Solutions on the Retention of Precision Attachments: An In Vitro Study.

Authors:  Gonca Deste Gokay; Serhat Emre Ozkir; Thomas Gerhard Wolf; Gulsum Gokcimen; Nergiz Rona; Mehmet Bicer; Burak Yilmaz
Journal:  Int J Environ Res Public Health       Date:  2022-04-05       Impact factor: 3.390

7.  An in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures.

Authors:  Tejomaya Shastry; N M Anupama; Shilpa Shetty; M Nalinakshamma
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.