Measurement of glucose levels in the newborn.

Kathryn Beardsall1.   

Abstract

Accurate measurement of blood glucose levels in the newborn is important as hypoglycaemia and hyperglycaemia are common treatable conditions and there is evidence linking both with detrimental clinical outcomes. Point of care (POC) glucose testing provides rapid results with small sample volumes and therefore clinical care can be modified quickly if needed. However the common thresholds for the diagnosis of hypoglycaemia in the newborn (blood glucose <2.0 mmol/l or <2.6 mmol/l) and hyperglycaemia (blood glucose >10 mmol/l) are at the limits of accuracy for many POC glucose analysers. Therefore although useful for screening, such devices cannot be relied upon for accurate diagnosis of hypoglycaemia. Stand alone local laboratory devices or glucose biosensors incorporated into blood gas analysers help to balance the benefits of POC testing with the accuracy of laboratory analyses. However these clinical methods all rely on intermittent blood sampling and there may be many hours between measurements, when both hypoglycaemia and hyperglycaemia may be undetected clinically. Less invasive and continuous methods of glucose monitoring are under development. Continuous glucose monitoring provides detailed information regarding glucose levels and has led to improvements in the care of patients with diabetes mellitus. These devices also have the potential to help provide improved glucose monitoring and management in the high risk neonate. 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20542649     DOI: 10.1016/j.earlhumdev.2010.05.005

Source DB:  PubMed          Journal:  Early Hum Dev        ISSN: 0378-3782            Impact factor:   2.079


  12 in total

1.  Serial investigation of continuous glucose monitoring in a very low birth weight infant with transient late-onset hyperglycemia.

Authors:  Toshihiko Nakamura; Daisuke Hatanaka; Mari Nakamura; Michiko Kusakari; Hidehiro Takahashi; Takashi Kamohara
Journal:  Fukushima J Med Sci       Date:  2016-11-03

Review 2.  Oral dextrose gel for the treatment of hypoglycaemia in newborn infants.

Authors:  Taygen Edwards; Gordon Liu; Malcolm Battin; Deborah L Harris; Joanne E Hegarty; Philip J Weston; Jane E Harding
Journal:  Cochrane Database Syst Rev       Date:  2022-03-18

3.  Cost Analysis of Cot-Side Screening Methods for Neonatal Hypoglycaemia.

Authors:  Matthew J Glasgow; Jane E Harding; Richard Edlin
Journal:  Neonatology       Date:  2018-06-12       Impact factor: 4.035

Review 4.  Point-of-care diagnostics to improve maternal and neonatal health in low-resource settings.

Authors:  Catherine E Majors; Chelsey A Smith; Mary E Natoli; Kathryn A Kundrod; Rebecca Richards-Kortum
Journal:  Lab Chip       Date:  2017-10-11       Impact factor: 6.799

5.  Real-time continuous glucose monitoring reduces the duration of hypoglycemia episodes: a randomized trial in very low birth weight neonates.

Authors:  Florence Uettwiller; Aude Chemin; Elisabeth Bonnemaison; Géraldine Favrais; Elie Saliba; François Labarthe
Journal:  PLoS One       Date:  2015-01-15       Impact factor: 3.240

6.  Factors influencing glycaemic stability after neonatal hypoglycaemia and relationship to neurodevelopmental outcome.

Authors:  Nataliia Burakevych; Christopher J D McKinlay; Deborah L Harris; Jane M Alsweiler; Jane E Harding
Journal:  Sci Rep       Date:  2019-05-31       Impact factor: 4.379

7.  Real-time continuous glucose monitoring in preterm infants (REACT): an international, open-label, randomised controlled trial.

Authors:  Kathryn Beardsall; Lynn Thomson; Catherine Guy; Isabel Iglesias-Platas; Mirjam M van Weissenbruch; Simon Bond; Annabel Allison; Sungwook Kim; Stavros Petrou; Beatrice Pantaleo; Roman Hovorka; David Dunger
Journal:  Lancet Child Adolesc Health       Date:  2021-02-10

Review 8.  Continuous glucose monitoring in neonates: a review.

Authors:  Christopher J D McKinlay; J Geoffrey Chase; Jennifer Dickson; Deborah L Harris; Jane M Alsweiler; Jane E Harding
Journal:  Matern Health Neonatol Perinatol       Date:  2017-10-17

9.  Protocol of a randomised controlled trial of real-time continuous glucose monitoring in neonatal intensive care 'REACT'.

Authors:  Kathryn Beardsall; Lynn Thomson; Catherine Guy; Mirjam M van Weissenbruch; Isabel Iglesias; Priya Muthukumar; Sateesh Kumar Somisetty; Simon Bond; Stavros Petrou; David Dunger
Journal:  BMJ Open       Date:  2018-06-04       Impact factor: 2.692

10.  Assessment of the performance of blood glucose monitoring systems for monitoring dysglycaemia in neonatal patients.

Authors:  Yin Ba; Jin Xu; Lin Yuan; Haiyan Zhu; Yipei Yang; Mei Mei Lam; Shulian Zhang; Mili Xiao; Jiayin Xu; Rong Zhang; Chao Chen
Journal:  BMJ Paediatr Open       Date:  2018-10-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.