Kathryn Beardsall1,2, Lynn Thomson1,2, Catherine Guy1, Mirjam M van Weissenbruch3, Isabel Iglesias4, Priya Muthukumar5, Sateesh Kumar Somisetty6, Simon Bond7, Stavros Petrou8, David Dunger1.
Abstract
INTRODUCTION: Hyperglycaemia is common in the very preterm infant and has been associated with adverse outcomes. Preventing hyperglycaemia without increasing the risk of hypoglycaemia has proved challenging. The development of real-time continuous glucose monitors (CGM) to inform treatment decisions provides an opportunity to reduce this risk. This study aims to assess the feasibility of CGM combined with a specifically designed paper guideline to target glucose control in the preterm infant. METHODS AND ANALYSES: The Real Time Continuous Glucose Monitoring in Neonatal Intensive Care (REACT) trial is an international multicentre randomised controlled trial. 200 preterm infants ≤1200 g and ≤24 hours of age will be randomly allocated to either real-time CGM or standard care (with blinded CGM data collection). The primary outcome is time in target 2.6-10 mmol/L during the study intervention assessed using CGM. Secondary outcomes include efficacy relating to glucose control, utility including staff acceptability, safety outcomes relating to incidence and prevalence of hypoglycaemia and health economic analyses. ETHICS AND DISSEMINATION: The REACT trial has been approved by the National Health Service Health Research Authority National Research Ethics Service Committee East of England (Cambridge Central); Medical Ethics Review Committee, VU University Medical Centre, Amsterdam, The Netherlands and the Research Ethics Committee, Sant Joan de Déu Research Foundation, Barcelona, Spain. Recruitment began in July 2016 and will continue until mid-2018. The trial has been adopted by the National Institute of Health Research Clinical Research Network portfolio (ID: 18826) and is registered with anInternational Standard Randomised Control Number (ISRCTN registry ID: 12793535). Dissemination plans include presentations at scientific conferences, scientific publications and efforts at stakeholder engagement. TRIAL REGISTRATION NUMBER: ISRCTN12793535; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.Entities:
Keywords: continuous monitoring; glucose; hyperglycaemia; hypoglycaemia; randomised controlled trial
Mesh:
Substances:
Year: 2018 PMID: 29866729 PMCID: PMC5988133 DOI: 10.1136/bmjopen-2017-020816
Source DB: PubMed Journal: BMJ Open ISSN: 2044-6055 Impact factor: 2.692
Figure 1The Enlite glucose sensor (Medtronic, Watford UK).
Figure 2The Enlite glucose sensor with The Guardian 2 Link transmitter attached.
Figure 3MiniMed 640G (Medtronic, Watford UK).