The chemical form of metallic debris in tissues surrounding metal-on-metal hips with unexplained failure.

Alister J Hart1, Paul D Quinn, Barry Sampson, Ann Sandison, Kirk D Atkinson, John A Skinner, Jonathan J Powell, J Fred W Mosselmans.   

Abstract

Implant-derived material from metal-on-metal (MOM) hip arthroplasties may be responsible for an unexplained tissue inflammatory response. The chemical form of the metal species in the tissues is predominantly chromium (Cr), but the currently used techniques have not been able to determine whether this is Cr(III) phosphate or Cr(III) oxide. The analytical challenge must overcome the fact that the metal in the tissues is at a relatively low concentration and tissue preparation or the microscopy beam used can affect the results. Microfocus X-ray spectroscopy using a synchrotron beam is useful in addressing both these issues. Using this technique we compared tissue from failed MOM hips with: (1) tissue from metal-on-polyethylene (MOP) hips; (2) chemical standards; (3) metal discs cut from MOM hips. The most abundant implant-related species in all MOM hip tissues contained Cr. Comparison with standards revealed the chemical form was Cr(III) phosphate, which did not vary with manufacturer type (four types analysed) or level of blood metal ions. Cobalt (Co) and molybdenum (Mo) were occasionally present in areas of high Cr. Co was normally found in a metallic state in the tissue, while Mo was found in an oxidized state. The variety of metallic species may have arisen from corrosion, wear or a combination of both. No evidence of Cr(VI) was seen in the tissues examined.
Copyright © 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20541630     DOI: 10.1016/j.actbio.2010.06.006

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  22 in total

1.  Simple isolation method for the bulk isolation of wear particles from metal on metal bearing surfaces generated in a hip simulator test.

Authors:  Fang Lu; Matt Royle; Ferdinand V Lali; Alister J Hart; Simon Collins; Jonathan Housden; Julia C Shelton
Journal:  J Mater Sci Mater Med       Date:  2012-03-06       Impact factor: 3.896

Review 2.  What is the trouble with trunnions?

Authors:  Christina I Esposito; Timothy M Wright; Stuart B Goodman; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

3.  Revision of Metal-on-metal Hip Prostheses Results in Marked Reduction of Blood Cobalt and Chromium Ion Concentrations.

Authors:  Olli Lainiala; Aleksi Reito; Petra Elo; Jorma Pajamäki; Timo Puolakka; Antti Eskelinen
Journal:  Clin Orthop Relat Res       Date:  2015-01-27       Impact factor: 4.176

4.  The effect of hyaluronic acid on the corrosion of an orthopedic CoCrMo-alloy in simulated inflammatory conditions.

Authors:  S Radice; J Yao; J Babauta; M P Laurent; M A Wimmer
Journal:  Materialia (Oxf)       Date:  2019-05-10

5.  The effect of 3 wt.% Cu addition on the microstructure, tribological property and corrosion resistance of CoCrW alloys fabricated by selective laser melting.

Authors:  Jiasi Luo; Songquan Wu; Yanjin Lu; Sai Guo; Yang Yang; Chaoqian Zhao; Junjie Lin; Tingting Huang; Jinxin Lin
Journal:  J Mater Sci Mater Med       Date:  2018-03-19       Impact factor: 3.896

6.  Fourier transform infrared spectroscopic imaging of wear and corrosion products within joint capsule tissue from total hip replacements patients.

Authors:  Songyun Liu; Deborah J Hall; Stephanie M McCarthy; Joshua J Jacobs; Robert M Urban; Robin Pourzal
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2019-05-17       Impact factor: 3.368

7.  Self-reported systemic complaints in patients with metal-on-metal hip arthroplasty.

Authors:  Jetse Jelsma; Martijn Schotanus; Henne Kleinveld; Bernd Grimm; Ide Heyligers
Journal:  J Orthop       Date:  2020-01-25

8.  Fretting-corrosion of CoCr-alloys against TiAl6V4: The importance of molybdenum in oxidative biological environments.

Authors:  M A Wimmer; S Radice; D Janssen; A Fischer
Journal:  Wear       Date:  2021-03-10       Impact factor: 4.695

Review 9.  Management of metal-on-metal hip implant patients: Who, when and how to revise?

Authors:  Reshid Berber; John A Skinner; Alister J Hart
Journal:  World J Orthop       Date:  2016-05-18

10.  [MRI investigations in patients with problems due to metal-on-metal implants].

Authors:  T M Parsons; K Satchithananda; R Berbe; I A Siddiqui; E Robinson; A J Hart; A Hart
Journal:  Orthopade       Date:  2013-08       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.