Literature DB >> 20541414

Repeatability of a new protocol for gait analysis in adult subjects.

Mario Manca1, Alberto Leardini, Stefano Cavazza, Giovanni Ferraresi, Pia Marchi, Emanuele Zanaga, Maria Grazia Benedetti.   

Abstract

The reliability of kinematic measurements has a top priority in gait analysis. The aim of the present work was to assess the inter-trial, inter-session and inter-examiner variability of an anatomical-based protocol by an established method. The gait of two young adult volunteers was analyzed by four examiners with different degrees of experience in three sessions 1 week apart. The data of five trials of level walking were collected and the rotations in the three anatomical planes of the pelvis, hip, knee and ankle were calculated. The mean value over the gait cycle of the standard deviation of these rotations was calculated for each of the 24 groups of five trials (inter-trial), the eight groups of five trials multiplied by three sessions (inter-session), and the two groups of five trials multiplied by three sessions multiplied by four examiners (inter-examiner). For each rotation, the inter-examiner variability was larger than the inter-session, and the latter larger than the inter-trial. The present ratio between inter-examiner and inter-trial variability was found to be smaller than that of the conventional protocol for each of the gait variables. Copyright 2010 Elsevier B.V. All rights reserved.

Mesh:

Year:  2010        PMID: 20541414     DOI: 10.1016/j.gaitpost.2010.05.011

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  7 in total

1.  Muscle activity around the knee and gait performance in unicompartmental knee arthroplasty patients: a comparative study on fixed- and mobile-bearing designs.

Authors:  Fabio Catani; Maria Grazia Benedetti; Luca Bianchi; Valentina Marchionni; Sandro Giannini; Alberto Leardini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-08-10       Impact factor: 4.342

2.  Accuracy and repeatability of smartphone sensors for measuring shank-to-vertical angle.

Authors:  Brandon T Nguyen; Nick A Baicoianu; Darrin B Howell; Keshia M Peters; Katherine M Steele
Journal:  Prosthet Orthot Int       Date:  2020-04-21       Impact factor: 1.895

3.  Test-Retest Reliability of a Conventional Gait Model for Registering Joint Angles during Initial Contact and Toe-Off in Healthy Subjects.

Authors:  Francisco Molina-Rueda; Pilar Fernández-González; Alicia Cuesta-Gómez; Aikaterini Koutsou; María Carratalá-Tejada; Juan Carlos Miangolarra-Page
Journal:  Int J Environ Res Public Health       Date:  2021-02-02       Impact factor: 3.390

4.  Pedobarographic and kinematic analysis in the functional evaluation of two post-operative forefoot offloading shoes.

Authors:  Paolo Caravaggi; Alessia Giangrande; Lisa Berti; Giada Lullini; Alberto Leardini
Journal:  J Foot Ankle Res       Date:  2015-10-29       Impact factor: 2.303

5.  Kinematic Analysis of a Six-Degrees-of-Freedom Model Based on ISB Recommendation: A Repeatability Analysis and Comparison with Conventional Gait Model.

Authors:  Magdalena Żuk; Celina Pezowicz
Journal:  Appl Bionics Biomech       Date:  2015-01-29       Impact factor: 1.781

6.  Reliability and Repeatability of ACL Quick Check®: A Methodology for on Field Lower Limb Joint Kinematics and Kinetics Assessment in Sport Applications.

Authors:  Annamaria Guiotto; Alfredo Ciniglio; Fabiola Spolaor; Davide Pavan; Federica Cibin; Alex Scaldaferro; Zimi Sawacha
Journal:  Sensors (Basel)       Date:  2021-12-30       Impact factor: 3.576

7.  Gait patterns in hemiplegic patients with equinus foot deformity.

Authors:  M Manca; G Ferraresi; M Cosma; L Cavazzuti; M Morelli; M G Benedetti
Journal:  Biomed Res Int       Date:  2014-04-22       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.