Literature DB >> 20541359

Kneeling is safe for patients implanted with medial-pivot total knee arthroplasty designs.

C Lowry Barnes1, Adrija Sharma, J David Blaha, Satya N Nambu, Michael E Carroll.   

Abstract

Nine ADVANCE (Wright Medical Technology, Arlington, TN)) Medial-Pivot (MP) and 9 ADVANCE Double-High total knee arthroplasties were analyzed under radiographic surveillance at standing, mid kneeling, and full kneeling. In vivo tibiofemoral contact positions were obtained using the 3- to 2-dimensional image registration technique. The contact in Double-High knee was always more posterior than that in the MP knee presumably because of the presence of the posterior cruciate ligament. The contact positions in both the designs moved anterior from standing to mid kneeling, moved posterior from mid kneeling to full kneeling, and remained within the intended articulation range of the implants. This study indicates that kneeling is safe in MP total knee arthroplasty even in the absence of a cam-post or posterior cruciate ligament.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20541359     DOI: 10.1016/j.arth.2010.04.027

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  14 in total

Review 1.  Medial pivot knee in primary total knee arthroplasty.

Authors:  Francesco Atzori; Wael Salama; Luigi Sabatini; Shazly Mousa; Abdelrahman Khalefa
Journal:  Ann Transl Med       Date:  2016-01

2.  The kneeling test is a valid method of assessing kneeling tolerance.

Authors:  Nicholas D Calvert; Anne Smith; Lukas Kuster; Maya Calvert; Jay Ebert; Tim Ackland; Markus S Kuster
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-04-09       Impact factor: 4.342

3.  Are knee savers and knee pads a viable intervention to reduce lower extremity musculoskeletal disorder risk in residential roofers?

Authors:  Scott P Breloff; Amrita Dutta; Erik W Sinsel; Robert E Carey; Christopher M Warren; Fei Dai; Shawn Ning; John Z Wu
Journal:  Int J Ind Ergon       Date:  2019-11       Impact factor: 2.656

4.  Evaluation of patellofemoral joint in ADVANCE Medial-pivot total knee arthroplasty.

Authors:  Nobuaki Chinzei; Kazunari Ishida; Tomoyuki Matsumoto; Yuichi Kuroda; Atsushi Kitagawa; Ryosuke Kuroda; Toshihiro Akisue; Kotaro Nishida; Masahiro Kurosaka; Nobuhiro Tsumura
Journal:  Int Orthop       Date:  2013-08-08       Impact factor: 3.075

5.  In vivo comparisons of patellofemoral kinematics before and after ADVANCE Medial-Pivot total knee arthroplasty.

Authors:  Kazunari Ishida; Tomoyuki Matsumoto; Nobuhiro Tsumura; Nobuaki Chinzei; Atsushi Kitagawa; Seiji Kubo; Takaaki Chin; Tetsuhiro Iguchi; Toshihiro Akisue; Kotaro Nishida; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Int Orthop       Date:  2012-08-11       Impact factor: 3.075

6.  Is the posterior cruciate ligament necessary for medial pivot knee prostheses with regard to postoperative kinematics?

Authors:  Chao-Hua Fang; Chia-Ming Chang; Yu-Shu Lai; Wen-Chuan Chen; Da-Yong Song; Colin J McClean; Hao-Yuan Kao; Tie-Bing Qu; Cheng-Kung Cheng
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-26       Impact factor: 4.342

7.  Posterior femoral translation in medial pivot total knee arthroplasty of posterior cruciate ligament retaining type.

Authors:  Su Hyun Cho; Hyung Lae Cho; Soo Ho Lee; Hong Ki Jin
Journal:  J Orthop       Date:  2013-05-18

8.  Mid-term clinical results of alumina medial pivot total knee arthroplasty.

Authors:  Takahiro Iida; Yukihide Minoda; Yoshinori Kadoya; Yoshio Matsui; Akio Kobayashi; Hiroyoshi Iwaki; Mitsuhiko Ikebuchi; Taku Yoshida; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-05       Impact factor: 4.342

9.  Influence of component design on in vivo tibiofemoral contact patterns during kneeling after total knee arthroplasty: a systematic review and meta-analysis.

Authors:  Joseph T Lynch; Jennie M Scarvell; Catherine R Galvin; Paul N Smith; Diana M Perriman
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-04-03       Impact factor: 4.342

10.  No difference between double-high insert and medial-pivot insert in TKA.

Authors:  Kazunari Ishida; Tomoyuki Matsumoto; Nobuhiro Tsumura; Takashi Iwakura; Seiji Kubo; Tetsuhiro Iguchi; Toshihiro Akisue; Kotaro Nishida; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-09       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.