Literature DB >> 20539884

Trace detection of non-uniformly distributed analytes on surfaces using mass transfer and large-area desorption electrospray ionization (DESI) mass spectrometry.

Santosh Soparawalla1, Gary A Salazar, Ewa Sokol, Richard H Perry, R Graham Cooks.   

Abstract

Ambient ionization methods such as desorption electrospray ionization (DESI) allow the analysis of chemicals adsorbed at surfaces without the need for sample (or surface) pretreatment. A limitation of current implementations of these ionization sources is the small size of the area that can be sampled. This makes examination of surfaces of large areas time-consuming because of the need to raster across the surface. This paper describes a DESI source that produces a spray plume with an effective desorption/ionization area of 3.6 cm(2), some 200 times larger than given by conventional DESI sources. Rhodamine 6G and several drugs of abuse (codeine, heroin and diazepam) were used to demonstrate the ability to use large-area DESI MS to perform rapid (a few seconds) representative sampling of areas of the order of several square centimetres without scanning the probe across the surface. The large area ion source displayed high sensitivity (limits of detection in the high nanogram range) and high reproducibility (approximately 20 to 35% relative standard deviation). The rapid analysis of even larger surfaces (hundreds of cm(2)) for traces of explosives is possible using a sorbent surface wipe followed by large-area DESI interrogation performed directly on the wipe material. The performance of this mass transfer dry wipe method was examined by determination of the limits of detection of several explosives. Surfaces with different topographies and compositions were also tested. Using this method, absolute limits of detection observed for HMX and RDX from plastic surfaces and skin were found to be as low as 10 ng cm(-2). The concentration of residue from large surface areas in this technique allowed the detection of 100 ng of explosives from surfaces with areas ranging from 1.00 x 10(3) cm(2) to 1.40 x 10(4) cm(2).

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20539884     DOI: 10.1039/c0an00189a

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  4 in total

1.  Enhanced Desorption Electrospray Ionization Mass Spectrometry via Synchronizing Ion Generation and Ion Injection.

Authors:  Zhuanghao Hou; Xingchuang Xiong; Xiang Fang; Guangming Huang
Journal:  J Am Soc Mass Spectrom       Date:  2018-11-06       Impact factor: 3.109

2.  The persistence of illicit drug smoke residues and their recovery from common household surfaces.

Authors:  Julie L Bitter
Journal:  Drug Test Anal       Date:  2016-06-22       Impact factor: 3.345

Review 3.  Recent advances in ambient mass spectrometry of trace explosives.

Authors:  Thomas P Forbes; Edward Sisco
Journal:  Analyst       Date:  2018-04-30       Impact factor: 4.616

4.  Ambient DESI and LESA-MS analysis of proteins adsorbed to a biomaterial surface using in-situ surface tryptic digestion.

Authors:  Wei Rao; Adam D Celiz; David J Scurr; Morgan R Alexander; David A Barrett
Journal:  J Am Soc Mass Spectrom       Date:  2013-09-19       Impact factor: 3.109

  4 in total