Literature DB >> 20539215

Corneal tissue welding with infrared laser irradiation after clear corneal incision.

Rfat Rasier1, Mediha Ozeren, Ozgür Artunay, Halil Bahçecioğlu, Ismail Seçkin, Hamit Kalaycoğlu, Adnan Kurt, Alphan Sennaroğlu, Murat Gülsoy.   

Abstract

PURPOSE: The aim of this study was to investigate the potential of infrared lasers for corneal welding to seal corneal cuts done in an experimental animal model.
MATERIALS AND METHODS: Full-thickness corneal cuts on freshly enucleated bovine eyes were irradiated with infrared (809-nm diode, 980-nm diode, 1070-nm YLF, and 1980-nm Tm:YAP) lasers to get immediate laser welding. An 809-nm laser was used with the topical application of indocyanine green to enhance the photothermal interaction at the weld site. In total, 60 bovine eyes were used in this study; 40 eyes were used in the first part of the study for the determination of optimal welding parameters (15 eyes were excluded because of macroscopic carbonization, opacification, or corneal shrinkage; 2 eyes were used for control), and 20 eyes were used for further investigation of more promising lasers (YLF and Tm:YAP). Laser wavelength, irradiating power, exposure time, and spot size were the dose parameters, and optimal dose for immediate closure with minimal thermal damage was estimated through histological examination of welded samples.
RESULTS: In the first part of the study, results showed that none of the applications was satisfactory. Full-thickness success rates were 28% (2 of 7) for 809-nm and for 980-nm diode lasers and 67% (2 of 3) for 1070-nm YLF and (4 of 6) for 1980-nm Tm:YAP lasers. In the second part of the study, YLF and Tm:YAP lasers were investigated with bigger sample size. Results were not conclusive but promising again. Five corneal incisions were full-thickness welded out of 10 corneas with 1070-nm laser, and 4 corneal incisions were partially welded out of 10 corneas with 1980-nm laser in the second part of the study.
CONCLUSIONS: Results showed that noteworthy corneal welding could be obtained with 1070-nm YLF laser and 1980-nm Tm:YAP laser wavelengths. Furthermore, in vitro and in vivo studies will shed light on the potential usage of corneal laser welding technique.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20539215     DOI: 10.1097/ICO.0b013e3181cc7a3e

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  4 in total

1.  Refining analgesia strategies using lasers.

Authors:  Victoria Hampshire
Journal:  Lab Anim (NY)       Date:  2015-08       Impact factor: 12.625

2.  Robot-assisted laser tissue soldering system.

Authors:  Svetlana Basov; Amit Milstein; Erez Sulimani; Max Platkov; Eli Peretz; Marcel Rattunde; Joachim Wagner; Uri Netz; Abraham Katzir; Ilana Nisky
Journal:  Biomed Opt Express       Date:  2018-10-19       Impact factor: 3.732

Review 3.  Cataract surgery and methods of wound closure: a review.

Authors:  Cynthia Matossian; Sarah Makari; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2015-05-22

4.  Strong bonding of corneal incisions using a noncontact fiber-optic laser soldering method.

Authors:  Svetlana Basov; David Varssano; Max Platkov; Ilan Gabay; Mordechai Rosner; Irina Barequet; Marcel Rattunde; Joachim Wagner; Mickey Harlev; Doron Ofer; Ilana Nisky; Yair Dankner; Abraham Katzir
Journal:  J Biomed Opt       Date:  2019-12       Impact factor: 3.170

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.