Literature DB >> 2053741

A safe method for sedating and monitoring patients for upper and lower gastrointestinal endoscopy.

I B Simon1, R J Lewis, R M Satava.   

Abstract

Although the incidence of significant complications occurring during endoscopic procedures that require sedation are low, it has been demonstrated that they are usually related to cardiovascular system dysfunction. Such complications are a manifestation of cardiac hypoxia and are a function of the arterial oxygen desaturation. A practical method of monitoring such patients includes continuous oxygen saturation measurements and EKG monitoring. From October, 1987 to July, 1989, a total of 730 endoscopic examinations were performed using a combination of meperidine and midazolam as an intravenous (IV) bolus for sedation. Supplemental nasal oxygen was routinely given at 2 L per minute and real-time monitoring was performed with electrocardiograph and continuous pulse oximeter. There were no deaths and only four untoward events related to medication that altered the course of the examination. Transient hypoxemia that responds to gentle stimulation and bradycardia resolving with cessation of endoscope advancement are viewed as physiologic responses and not complications. All occurrences were immediately identified and corrected appropriately, and no morbidity resulted. With proper monitoring of oxygen saturation, pulse, and cardiac rhythm in a patient with nasal oxygen, IV bolus administration of meperidine and midazolam is a safe and adequate sedation even in the elderly and debilitated patient.

Entities:  

Mesh:

Year:  1991        PMID: 2053741

Source DB:  PubMed          Journal:  Am Surg        ISSN: 0003-1348            Impact factor:   0.688


  5 in total

1.  Intravenous sedation in 200 geriatric patients undergoing office oral surgery.

Authors:  R L Campbell; P B Smith
Journal:  Anesth Prog       Date:  1997

2.  A study at 10 medical centers of the safety and efficacy of 48 flexible sigmoidoscopies and 8 colonoscopies during pregnancy with follow-up of fetal outcome and with comparison to control groups.

Authors:  M S Cappell; V J Colon; O A Sidhom
Journal:  Dig Dis Sci       Date:  1996-12       Impact factor: 3.199

3.  Multicenter, multiyear study of safety and efficacy of flexible sigmoidoscopy during pregnancy in 24 females with follow-up of fetal outcome.

Authors:  M S Cappell; O Sidhom
Journal:  Dig Dis Sci       Date:  1995-02       Impact factor: 3.199

4.  Safety and clinical efficacy of flexible sigmoidoscopy and colonoscopy for gastrointestinal bleeding after myocardial infarction. A six-year study of 18 consecutive lower endoscopies at two university teaching hospitals.

Authors:  M S Cappell
Journal:  Dig Dis Sci       Date:  1994-03       Impact factor: 3.199

5.  Intravenous sedation in accident and emergency departments: a nationwide survey.

Authors:  B H Aslam; I Woods
Journal:  Ann R Coll Surg Engl       Date:  1994-01       Impact factor: 1.891

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.