NEMA NU 2-2001 performance testing of a Philips Gemini GXL PET/CT scanner.

Chithradevi Sathiakumar1, Seu Som, Stefan Eberl, Peter Lin.   

Abstract

Post installation acceptance testing is vital to demonstrate that the equipment meets the vendor's specification and is suitable for clinical studies. The test procedures described in the NEMA NU 2-2001 document form the basis of vendor performance specifications of PET scanners and hence are also appropriate for acceptance testing. Initial installation performance tests of the Philips Gemini GXL PET/CT scanner installed at Liverpool Hospital revealed that the peak noise equivalent count rate (NECR) measurement of 57.5 kcps was substantially lower than the specification of 70 kcps and the scatter fraction of 38.5% was 10% higher than the specification of <or=35%. These performance parameters potentially impact on clinical image quality and hence the deviations were considered unacceptable. The performance issues were addressed by the vendor through a hardware upgrade and optimisation of the energy window by increasing the lower discriminator value from 408.8 to 434.4 keV. Several repeat performance measurements taken from post-optimisation demonstrated improvement in peak NECR to 67 kcps with delayed window randoms subtraction "on" and 72 kcps with delayed window randoms subtraction "off". Scatter fraction taken from post upgrade and optimisation improved to an average of 33%, which is well within specification of <35%. All other performance tests (resolution, sensitivity, accuracy of corrections) were within specifications both prior and post-optimisation changes. This experience demonstrates the importance of equipment acceptance testing prior to clinical use so that deficiencies in performance can be addressed before the equipment is placed in clinical service.

Mesh:

Year:  2010        PMID: 20535650     DOI: 10.1007/s13246-010-0016-6

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  3 in total

1.  FDG uptake in cervical lymph nodes in children without head and neck cancer.

Authors:  Reza Vali; Alaa Bakkari; Eman Marie; Mahnaz Kousha; Martin Charron; Amer Shammas
Journal:  Pediatr Radiol       Date:  2017-03-29

2.  A NIM PET/CT phantom for evaluating the PET image quality of micro-lesions and the performance parameters of CT.

Authors:  Shujie Lu; Peng Zhang; Chengwei Li; Jie Sun; Wenli Liu; Pu Zhang
Journal:  BMC Med Imaging       Date:  2021-11-08       Impact factor: 1.930

3.  The impact of 18F-FDG PET on initial staging and therapy planning of pediatric soft-tissue sarcoma patients.

Authors:  Alaa Elmanzalawy; Reza Vali; Govind B Chavhan; Abha A Gupta; Yusuf Omarkhail; Afsaneh Amirabadi; Amer Shammas
Journal:  Pediatr Radiol       Date:  2019-10-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.