Literature DB >> 20531526

Noninvasive technique for oximetry of blood in retinal vessels.

F C Delori.   

Abstract

A noninvasive spectrophotometric technique for the measurement of oxygen saturation of the blood in discrete retinal vessels is described. The instrument, the retinal vessel oximeter, uses scanning fundus reflectometry to determine the optical density of a retinal vessel at three wavelengths (558, 569, and 686 nm). Oxygen saturation is determined after compensation for the effects of light scattering by the red blood cells by relating the measured densities with the corresponding extinction coefficients nf oxyhemoglobin and deoxy-genated hemoglobin. The vessel diameter is also measured continuously. All data acquisition and analysis are performed on-line by means of a microcomputer, and a vessel tracking system is used to compensate for the effects of eye movements. Oxygen saturation measurements for blood flowing through glass capillaries are presented as well as representative results of oxygen saturation measurements on normal human subjects.

Entities:  

Year:  1988        PMID: 20531526     DOI: 10.1364/AO.27.001113

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  36 in total

1.  Oximetry with a multiple wavelength SLO.

Authors:  R A Ashman; F Reinholz; R H Eikelboom
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

2.  Retinal oximeter for the blue-green oximetry technique.

Authors:  Kurt R Denninghoff; Katarzyna B Sieluzycka; Jennifer K Hendryx; Tyson J Ririe; Lawrence Deluca; Russell A Chipman
Journal:  J Biomed Opt       Date:  2011-10       Impact factor: 3.170

3.  Accuracy of retinal oximetry: a Monte Carlo investigation.

Authors:  Wenzhong Liu; Shuliang Jiao; Hao F Zhang
Journal:  J Biomed Opt       Date:  2013-06       Impact factor: 3.170

4.  Dynamic eye phantom for retinal oximetry measurements.

Authors:  Paul Lemaillet; Jessica C Ramella-Roman
Journal:  J Biomed Opt       Date:  2009 Nov-Dec       Impact factor: 3.170

5.  Spectral oximetry assessed with high-speed ultra-high-resolution optical coherence tomography.

Authors:  Larry Kagemann; Gadi Wollstein; Maciej Wojtkowski; Hiroshi Ishikawa; Kelly A Townsend; Michelle L Gabriele; Vivek J Srinivasan; James G Fujimoto; Joel S Schuman
Journal:  J Biomed Opt       Date:  2007 Jul-Aug       Impact factor: 3.170

6.  Spectral imaging of the retina.

Authors:  D J Mordant; I Al-Abboud; G Muyo; A Gorman; A Sallam; P Ritchie; A R Harvey; A I McNaught
Journal:  Eye (Lond)       Date:  2011-03       Impact factor: 3.775

7.  Quantitative microvascular hemoglobin mapping using visible light spectroscopic Optical Coherence Tomography.

Authors:  Shau Poh Chong; Conrad W Merkle; Conor Leahy; Harsha Radhakrishnan; Vivek J Srinivasan
Journal:  Biomed Opt Express       Date:  2015-03-24       Impact factor: 3.732

Review 8.  Paradigm Shifts in Ophthalmic Diagnostics.

Authors:  J Sebag; Alfredo A Sadun; Eric A Pierce
Journal:  Trans Am Ophthalmol Soc       Date:  2016-08

9.  Hyperspectral Image Mapping Spectrometry for Retinal Oximetry Measurements in Four Diseased Eyes.

Authors:  Jason G Dwight; Christina Y Weng; Robert E Coffee; Michal E Pawlowski; Tomasz S Tkaczyk
Journal:  Int Ophthalmol Clin       Date:  2016

10.  Three-dimensional mapping of chorioretinal vascular oxygen tension in the rat.

Authors:  Mahnaz Shahidi; Justin Wanek; Norman P Blair; Marek Mori
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-09-29       Impact factor: 4.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.