Literature DB >> 20059246

Dynamic eye phantom for retinal oximetry measurements.

Paul Lemaillet1, Jessica C Ramella-Roman.   

Abstract

Measurements of oxygen saturation and flow in the retina can yield information about eye health and the onset of eye pathologies such as diabetic retinopathy. Recently, we developed a multiaperture camera that uses the division of the retinal image into several wavelength-sensitive subimages to compute retinal oxygen saturation. The calibration of such instruments is particularly difficult due to the layered structure of the eye and the lack of alternative measurement techniques. For this purpose, we realize an in vitro model of the human eye composed of a lens, the retina vessel, and three layers: the choroid, the retinal pigmented epithelium, and the sclera. The retinal vessel is modeled with a microtube connected to a micropump and a hemoglobin reservoir in a closed circulatory system. Hemoglobin oxygenation in the vessel could be altered using a reversible fuel cell. The sclera is represented by a Spectralon slab. The optical properties of the other layers are mimicked using titanium dioxide as a scatterer, ink as an absorber, and epoxy as a supporting structure. The optical thickness of each layer of the eye phantom is matched to each respective eye layer.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20059246      PMCID: PMC2917460          DOI: 10.1117/1.3258669

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  21 in total

1.  Three-dimensional time-resolved optical tomography of a conical breast phantom.

Authors:  J C Hebden; H Veenstra; H Dehghani; E M Hillman; M Schweiger; S R Arridge; D T Delpy
Journal:  Appl Opt       Date:  2001-07-01       Impact factor: 1.980

2.  Quantitative reflection spectroscopy at the human ocular fundus.

Authors:  Martin Hammer; Dietrich Schweitzer
Journal:  Phys Med Biol       Date:  2002-01-21       Impact factor: 3.609

3.  Monte Carlo modelling of the spectral reflectance of the human eye.

Authors:  S J Preece; E Claridge
Journal:  Phys Med Biol       Date:  2002-08-21       Impact factor: 3.609

4.  A study of retinal venous blood oxygen saturation in human subjects by photographic means.

Authors:  J B HICKAM; R FRAYSER; J C ROSS
Journal:  Circulation       Date:  1963-03       Impact factor: 29.690

5.  Collection efficiency of a single optical fiber in turbid media.

Authors:  Paulo R Bargo; Scott A Prahl; Steven L Jacques
Journal:  Appl Opt       Date:  2003-06-01       Impact factor: 1.980

6.  Measurement of oxygen saturation in the retina with a spectroscopic sensitive multi aperture camera.

Authors:  Jessica C Ramella-Roman; Scott A Mathews; Haryipriya Kandimalla; Afshin Nabili; Donald D Duncan; Salvatore A D'Anna; Syed Mahmood Shah; Quan Dong Nguyen
Journal:  Opt Express       Date:  2008-04-28       Impact factor: 3.894

7.  Development of a tissue-equivalent phantom for diaphanography.

Authors:  J Linford; S Shalev; J Bews; R Brown; H Schipper
Journal:  Med Phys       Date:  1986 Nov-Dec       Impact factor: 4.071

8.  Spectral reflectance of the human ocular fundus.

Authors:  F C Delori; K P Pflibsen
Journal:  Appl Opt       Date:  1989-03-15       Impact factor: 1.980

9.  Optical properties of ocular fundus tissues--an in vitro study using the double-integrating-sphere technique and inverse Monte Carlo simulation.

Authors:  M Hammer; A Roggan; D Schweitzer; G Müller
Journal:  Phys Med Biol       Date:  1995-06       Impact factor: 3.609

Review 10.  Retinal oxygen: fundamental and clinical aspects.

Authors:  Norbert D Wangsa-Wirawan; Robert A Linsenmeier
Journal:  Arch Ophthalmol       Date:  2003-04
View more
  4 in total

1.  Absolute blood velocity measured with a modified fundus camera.

Authors:  Donald D Duncan; Paul Lemaillet; Mohamed Ibrahim; Quan Dong Nguyen; Matthias Hiller; Jessica Ramella-Roman
Journal:  J Biomed Opt       Date:  2010 Sep-Oct       Impact factor: 3.170

2.  Assessment of oxygen saturation in retinal vessels of normal subjects and diabetic patients with and without retinopathy using Flow Oximetry System.

Authors:  Mohamed A Ibrahim; Rachel E Annam; Yasir J Sepah; Long Luu; Millena G Bittencourt; Hyun S Jang; Paul Lemaillet; Beatriz Munoz; Donald D Duncan; Sheila West; Quan Dong Nguyen; Jessica C Ramella-Roman
Journal:  Quant Imaging Med Surg       Date:  2015-02

3.  Human eye phantom for developing computer and robot-assisted epiretinal membrane peeling.

Authors:  Amrita Gupta; Berk Gonenc; Marcin Balicki; Kevin Olds; James Handa; Peter Gehlbach; Russell H Taylor; Iulian Iordachita
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

4.  Microfluidics based phantoms of superficial vascular network.

Authors:  Long Luu; Patrick A Roman; Scott A Mathews; Jessica C Ramella-Roman
Journal:  Biomed Opt Express       Date:  2012-05-14       Impact factor: 3.732

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.