Literature DB >> 20527565

Diaphragm motion quantification in megavoltage cone-beam CT projection images.

Mingqing Chen1, R Alfredo Siochi.   

Abstract

PURPOSE: To quantify diaphragm motion in megavoltage (MV) cone-beam computed tomography (CBCT) projections.
METHODS: User identified ipsilateral hemidiaphragm apex (IHDA) positions in two full exhale and inhale frames were used to create bounding rectangles in all other frames of a CBCT scan. The bounding rectangle was enlarged to create a region of interest (ROI). ROI pixels were associated with a cost function: The product of image gradients and a gradient direction matching function for an ideal hemidiaphragm determined from 40 training sets. A dynamic Hough transform (DHT) models a hemidiaphragm as a contour made of two parabola segments with a common vertex (the IHDA). The images within the ROIs are transformed into Hough space where a contour's Hough value is the sum of the cost function over all contour pixels. Dynamic programming finds the optimal trajectory of the common vertex in Hough space subject to motion constraints between frames, and an active contour model further refines the result. Interpolated ray tracing converts the positions to room coordinates. Root-mean-square (RMS) distances between these positions and those resulting from an expert's identification of the IHDA were determined for 21 Siemens MV CBCT scans.
RESULTS: Computation time on a 2.66 GHz CPU was 30 s. The average craniocaudal RMS error was 1.38 +/- 0.67 mm. While much larger errors occurred in a few near-sagittal frames on one patient's scans, adjustments to algorithm constraints corrected them.
CONCLUSIONS: The DHT based algorithm can compute IHDA trajectories immediately prior to radiation therapy on a daily basis using localization MVCBCT projection data. This has potential for calibrating external motion surrogates against diaphragm motion.

Entities:  

Mesh:

Year:  2010        PMID: 20527565     DOI: 10.1118/1.3402184

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Surface-region context in optimal multi-object graph-based segmentation: robust delineation of pulmonary tumors.

Authors:  Qi Song; Mingqing Chen; Junjie Bai; Milan Sonka; Xiaodong Wu
Journal:  Inf Process Med Imaging       Date:  2011

2.  Automatic assessment of average diaphragm motion trajectory from 4DCT images through machine learning.

Authors:  Guang Li; Jie Wei; Hailiang Huang; Carl Philipp Gaebler; Amy Yuan; Joseph O Deasy
Journal:  Biomed Phys Eng Express       Date:  2015-12-29

3.  A constrained linear regression optimization algorithm for diaphragm motion tracking with cone beam CT projections.

Authors:  Jie Wei; Ming Chao
Journal:  Phys Med       Date:  2018-01-11       Impact factor: 2.685

4.  An algorithm to extract three-dimensional motion by marker tracking in the kV projections from an on-board imager: four-dimensional cone-beam CT and tumor tracking implications.

Authors:  Imad Ali; Nesreen Alsbou; Terence Herman; Salahuddin Ahmad
Journal:  J Appl Clin Med Phys       Date:  2011-02-01       Impact factor: 2.102

5.  Feasibility of using respiratory correlated mega voltage cone beam computed tomography to measure tumor motion.

Authors:  Mingqing Chen; R Alfredo Siochi
Journal:  J Appl Clin Med Phys       Date:  2011-01-31       Impact factor: 2.102

6.  Influence of acquisition parameters on MV-CBCT image quality.

Authors:  Olivier Gayou
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

7.  Tumor control probability reduction in gated radiotherapy of non-small cell lung cancers: a feasibility study.

Authors:  R Alfredo Siochi; Yusung Kim; Sudershan Bhatia
Journal:  J Appl Clin Med Phys       Date:  2014-10-16       Impact factor: 2.102

8.  Respiratory Motion Compensation Using Diaphragm Tracking for Cone-Beam C-Arm CT: A Simulation and a Phantom Study.

Authors:  Marco Bögel; Hannes G Hofmann; Joachim Hornegger; Rebecca Fahrig; Stefan Britzen; Andreas Maier
Journal:  Int J Biomed Imaging       Date:  2013-06-06

9.  Challenges and opportunities in patient-specific, motion-managed and PET/CT-guided radiation therapy of lung cancer: review and perspective.

Authors:  Stephen R Bowen; Matthew J Nyflot; Michael Gensheimer; Kristi R G Hendrickson; Paul E Kinahan; George A Sandison; Shilpen A Patel
Journal:  Clin Transl Med       Date:  2012-08-31

10.  Two-dimensional strain ultrasound speckle tracking as a novel approach for the evaluation of right hemidiaphragmatic longitudinal deformation.

Authors:  Xiong Ye; Hui Xiao; Weiming Bai; Yongjie Liang; Ming Chen; Suiyang Zhang
Journal:  Exp Ther Med       Date:  2013-05-30       Impact factor: 2.447

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.