Engineering silicone rubbers for in vitro studies: creating AAA models and ILT analogues with physiological properties.

T J Corbett1, B J Doyle, A Callanan, M T Walsh, T M McGloughlin.   

Abstract

In vitro studies of abdominal aortic aneurysm (AAA) have been widely reported. Frequently mock artery models with intraluminal thrombus (ILT) analogs are used to mimic the in vivo AAA. While the models used may be physiological, their properties are frequently either not reported or investigated. This study is concerned with the testing and characterization of previously used vessel analog materials and the development of new materials for the manufacture of AAA models. These materials were used in conjunction with a previously validated injection molding technique to manufacture AAA models of ideal geometry. To determine the model properties (stiffness (beta) and compliance), the diameter change of each AAA model was investigated under incrementally increasing internal pressures and compared with published in vivo studies to determine if the models behaved physiologically. A FEA study was implemented to determine if the pressure-diameter change behavior of the models could be predicted numerically. ILT analogs were also manufactured and characterized. Ideal models were manufactured with ILT analog internal to the aneurysm region, and the effect of the ILT analog on the model compliance and stiffness was investigated. The wall materials had similar properties (E(init) 2.22 MPa and 1.57 MPa) to aortic tissue at physiological pressures (1.8 MPa (from literature)). ILT analogs had a similar Young's modulus (0.24 MPa and 0.33 MPa) to the medial layer of ILT (0.28 MPa (from literature)). All models had aneurysm sac compliance (2.62-8.01 x 10(-4)/mm Hg) in the physiological range (1.8-9.4 x 10(-4)/mm Hg (from literature)). The necks of the AAA models had similar stiffness (20.44-29.83) to healthy aortas (17.5+/-5.5 (from literature)). Good agreement was seen between the diameter changes due to pressurization in the experimental and FEA wall models with a maximum difference of 7.3% at 120 mm Hg. It was also determined that the inclusion of ILT analog in the sac of the models could have an effect on the compliance of the model neck. Ideal AAA models with physiological properties were manufactured. The behavior of these models due to pressurization was predicted using finite element analysis, validating this technique for the future design of realistic physiological AAA models. Addition of ILT analogs in the aneurysm sac was shown to affect neck behavior. This could have implications for endovascular AAA repair due to the importance of the neck for stent-graft fixation.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20524746      PMCID: PMC2882675          DOI: 10.1115/1.4000156

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  32 in total

1.  Intrasac pressure waveforms after endovascular aneurysm repair (EVAR) are a reliable marker of type I endoleaks, but not type II or combined types: an experimental study.

Authors:  A Chaudhuri; L E Ansdell; A J Grass; M Adiseshiah
Journal:  Eur J Vasc Endovasc Surg       Date:  2004-10       Impact factor: 7.069

2.  Fabrication of vascular replicas from magnetic resonance images.

Authors:  M H Friedman; B D Kuban; P Schmalbrock; K Smith; T Altan
Journal:  J Biomech Eng       Date:  1995-08       Impact factor: 2.097

3.  Heterogeneity of tensile strength and matrix metalloproteinase activity in the wall of abdominal aortic aneurysms.

Authors:  Srinivasa R Vallabhaneni; Geoffrey L Gilling-Smith; Thien V How; Stuart D Carter; John A Brennan; Peter L Harris
Journal:  J Endovasc Ther       Date:  2004-08       Impact factor: 3.487

4.  Endotension is influenced by wall compliance in a latex aneurysm model.

Authors:  M Gawenda; P Knez; St Winter; G Jaschke; G Wassmer; Th Schmitz-Rixen; J Brunkwall
Journal:  Eur J Vasc Endovasc Surg       Date:  2004-01       Impact factor: 7.069

5.  Ultrasonic evaluation of abdominal aortic thrombus.

Authors:  L P Harter; B H Gross; P W Callen; R A Barth
Journal:  J Ultrasound Med       Date:  1982-10       Impact factor: 2.153

6.  Sex difference in the mechanical properties of the abdominal aorta in human beings.

Authors:  B Sonesson; T Länne; E Vernersson; F Hansen
Journal:  J Vasc Surg       Date:  1994-12       Impact factor: 4.268

7.  Non-axisymmetrical (life-like) abdominal aortic aneurysm models: a do-it-yourself approach.

Authors:  Arindam Chaudhuri; Leslie E Ansdell; Robin Richards; Mohan Adiseshiah; Anthony J Grass
Journal:  J Endovasc Ther       Date:  2003-12       Impact factor: 3.487

8.  Aneurysmal hypertension and its relationship to sac thrombus: a semi-qualitative analysis by experimental fluid mechanics.

Authors:  A Chaudhuri; L E Ansdell; A J Grass; M Adiseshiah
Journal:  Eur J Vasc Endovasc Surg       Date:  2004-03       Impact factor: 7.069

9.  The composition and mechanical properties of abdominal aortic aneurysms.

Authors:  C M He; M R Roach
Journal:  J Vasc Surg       Date:  1994-07       Impact factor: 4.268

10.  Endotension as a result of pressure transmission through the graft following endovascular aneurysm repair--an in vitro study.

Authors:  M Gawenda; G Jaschke; St Winter; G Wassmer; J Brunkwall
Journal:  Eur J Vasc Endovasc Surg       Date:  2003-11       Impact factor: 7.069

View more
  5 in total

1.  3D-Printed Tissue-Mimicking Phantoms for Medical Imaging and Computational Validation Applications.

Authors:  Aidan J Cloonan; Danial Shahmirzadi; Ronny X Li; Barry J Doyle; Elisa E Konofagou; Tim M McGloughlin
Journal:  3D Print Addit Manuf       Date:  2014-03-01       Impact factor: 5.449

2.  Detecting Regional Stiffness Changes in Aortic Aneurysmal Geometries Using Pressure-Normalized Strain.

Authors:  Doran S Mix; Ling Yang; Camille C Johnson; Nathan Couper; Ben Zarras; Isaac Arabadjis; Lauren E Trakimas; Michael C Stoner; Steven W Day; Michael S Richards
Journal:  Ultrasound Med Biol       Date:  2017-07-17       Impact factor: 2.998

3.  Mechanical properties and fibrin characteristics of endovascular coil-clot complexes: relevance to endovascular cerebral aneurysm repair paradigms.

Authors:  Kevin J Haworth; Christopher R Weidner; Todd A Abruzzo; Jason T Shearn; Christy K Holland
Journal:  J Neurointerv Surg       Date:  2014-03-25       Impact factor: 5.836

4.  3D Printing Low-Stiffness Silicone Within a Curable Support Matrix.

Authors:  Taylor E Greenwood; Serah E Hatch; Mark B Colton; Scott L Thomson
Journal:  Addit Manuf       Date:  2020-10-31

5.  Effect of manufacturing and experimental conditions on the mechanical and surface properties of silicone elastomer scaffolds used in endothelial mechanobiological studies.

Authors:  Marc-Antoine Campeau; Audrey Lortie; Pierrick Tremblay; Marc-Olivier Béliveau; Dominic Dubé; Ève Langelier; Léonie Rouleau
Journal:  Biomed Eng Online       Date:  2017-07-14       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.