Literature DB >> 2052339

Sources of noise in digital subtraction radiography.

A Wenzel1, I Sewerin.   

Abstract

In 17 patients, three identical radiographic examinations were performed for the lower premolar-molar region, by two examiners at one visit and by one examiner again approximately 3 months later. Recordings were performed with a newly developed device. The radiographs were converted to digital images in the following way: (1) video camera recording of the radiograph obtained at first visit by the first examiner (A), (2) copying of the numeric image of this radiograph (B), (3) repeated video recording of this radiograph (C), (4) video recording of the radiograph obtained at first visit by the second examiner (D), and (5) video recording of the radiograph obtained after 3 months (E). Subtractions were performed between the images: B - A, C - A, D - A, and E - A. The standard deviation of the histogram for the distribution of gray shades in the subtraction images was used to evaluate noise in the image. The standard deviation was 1.3 between B - A, 2.8 between C - A, 4.0 between D - A, and 4.1 between E - A. Physical noise originating from the video camera and the analog-to-digital conversion process thus constituted the major part of noise seen in subtraction images performed between radiographs recorded with a time interval. This indicates that reproducible recordings could be performed with the present device, which, in combination with a subtraction program able to correct for some geometry and density differences, may aid the use of subtraction radiography in clinical trials.

Entities:  

Mesh:

Year:  1991        PMID: 2052339     DOI: 10.1016/0030-4220(91)90441-e

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol        ISSN: 0030-4220


  8 in total

1.  Comparison of changes in dental and bone radiographic densities in the presence of different soft-tissue simulators using pixel intensity and digital subtraction analyses.

Authors:  R S de Molon; R G Batitucci; R Spin-Neto; G M Paquier; C E Sakakura; G M Tosoni; G Scaf
Journal:  Dentomaxillofac Radiol       Date:  2013-09-04       Impact factor: 2.419

2.  Evaluation of a metal artefact reduction tool on different positions of a metal object in the FOV.

Authors:  Polyane M Queiroz; Gustavo M Santaella; Thais D J da Paz; Deborah Q Freitas
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

3.  Variation in voxel value distribution and effect of time between exposures in six CBCT units.

Authors:  R Spin-Neto; E Gotfredsen; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2014-02-03       Impact factor: 2.419

4.  Assessment of three methods of geometric image reconstruction for digital subtraction radiography.

Authors:  Polyane M Queiroz; Matheus L Oliveira; Jefferson L O Tanaka; Milton G Soares; Francisco Haiter-Neto; Evelise Ono
Journal:  Dentomaxillofac Radiol       Date:  2016-07-19       Impact factor: 2.419

5.  High-tech breakthrough DNA scanner for reading sequence and detecting gene mutation. A powerful 1 lb, 20 micron resolution, 16-bit personal scanner (PS) that scans 17" x 14" X-ray film in 48 s, with laser, UV and white light sources.

Authors:  J A Zeineh; M M Zeineh; R A Zeineh
Journal:  Appl Biochem Biotechnol       Date:  1993-06       Impact factor: 2.926

6.  The impact of digital filters on the diagnosis of simulated root resorptions in digital radiographic systems.

Authors:  Nicolly Oliveira-Santos; Hugo Gaêta-Araujo; Débora Costa Ruiz; Eduarda Helena Leandro Nascimento; Wilson Gustavo Cral; Christiano Oliveira-Santos; Francisco Carlos Groppo
Journal:  Clin Oral Investig       Date:  2022-03-10       Impact factor: 3.606

Review 7.  Choice of diagnostic and therapeutic imaging in periodontics and implantology.

Authors:  Swarna Chakrapani; K Sirisha; Anumadi Srilalitha; Moogala Srinivas
Journal:  J Indian Soc Periodontol       Date:  2013-11

8.  Metal artifact production and reduction in CBCT with different numbers of basis images.

Authors:  Polyane Mazucatto Queiroz; Gustavo Machado Santaella; Francisco Carlos Groppo; Deborah Queiroz Freitas
Journal:  Imaging Sci Dent       Date:  2018-03-19
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.