Image-derived input function from cardiac gated maximum a posteriori reconstructed PET images in mice.

Landon W Locke1, Stuart S Berr, Bijoy K Kundu.   

Abstract

PURPOSE: The purpose of this study was to determine if accurate image-derived input functions (IDIF) can be measured from cardiac gated positron emission tomography (PET) images reconstructed using ordered subset expectation maximization-maximum a posteriori (OSEM-MAP) without further correction. PROCEDURES: IDIFs from the left ventricle were measured from cardiac gated PET images reconstructed using OSEM-MAP with computed tomography (CT)-based attenuation correction for five C57/BL6 mice. The accuracy of the IDIF was tested against blood samples using Bland-Altman analysis.
RESULTS: Image-derived blood radioactivity concentration values were not significantly different from sampled blood values at two late time points as determined by a paired t test (P = 0.97). Bland-Altman analysis revealed a mean difference of 0.06 μCi/ml (1%). Using kinetic analysis, the mean myocardial 2-deoxy-2-[(18)F]fluoro-D-glucose uptake rate constant based on the IDIF was comparable to values reported in the literature based on physical blood sampling.
CONCLUSIONS: Accurate IDIFs can be obtained non-invasively. Although reconstruction times are increased, no further spillover corrections are necessary for IDIFs derived from gated, OSEM-MAP reconstructed images with attenuation correction.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 20521133      PMCID: PMC3036775          DOI: 10.1007/s11307-010-0347-4

Source DB:  PubMed          Journal:  Mol Imaging Biol        ISSN: 1536-1632            Impact factor:   3.488


  11 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Glucose permeability in nonprimate erythrocytes.

Authors:  D B Buxton
Journal:  J Nucl Med       Date:  1999-12       Impact factor: 10.057

3.  Attenuation correction for small animal PET tomographs.

Authors:  Patrick L Chow; Fernando R Rannou; Arion F Chatziioannou
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

4.  Hybrid image and blood sampling input function for quantification of small animal dynamic PET data.

Authors:  Kooresh I Shoghi; Michael J Welch
Journal:  Nucl Med Biol       Date:  2007-09-19       Impact factor: 2.408

5.  High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner.

Authors:  J Qi; R M Leahy; S R Cherry; A Chatziioannou; T H Farquhar
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

6.  Minimally invasive method of determining blood input function from PET images in rodents.

Authors:  Joonyoung Kim; Pilar Herrero; Terry Sharp; Richard Laforest; Douglas J Rowland; Yuan-Chuan Tai; Jason S Lewis; Michael J Welch
Journal:  J Nucl Med       Date:  2006-02       Impact factor: 10.057

7.  Tomographic measurement of local cerebral glucose metabolic rate in humans with (F-18)2-fluoro-2-deoxy-D-glucose: validation of method.

Authors:  M E Phelps; S C Huang; E J Hoffman; C Selin; L Sokoloff; D E Kuhl
Journal:  Ann Neurol       Date:  1979-11       Impact factor: 10.422

8.  In vivo quantitation of glucose metabolism in mice using small-animal PET and a microfluidic device.

Authors:  Hsiao-Ming Wu; Guodong Sui; Cheng-Chung Lee; Mayumi L Prins; Waldemar Ladno; Hong-Dun Lin; Amy S Yu; Michael E Phelps; Sung-Cheng Huang
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

9.  Spillover and partial-volume correction for image-derived input functions for small-animal 18F-FDG PET studies.

Authors:  Yu-Hua Dean Fang; Raymond F Muzic
Journal:  J Nucl Med       Date:  2008-03-14       Impact factor: 10.057

10.  Left ventricular functional assessment in mice: feasibility of high spatial and temporal resolution ECG-gated blood pool SPECT.

Authors:  Bennett B Chin; Scott D Metzler; Anthony Lemaire; Antonio Curcio; Sreekanth Vemulapalli; Kim L Greer; Neil A Petry; Timothy G Turkington; R Edward Coleman; Howard Rockman; Ronald J Jaszczak
Journal:  Radiology       Date:  2007-11       Impact factor: 11.105

View more
  16 in total

Review 1.  Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls.

Authors:  Arman Rahmim; Jinyi Qi; Vesna Sossi
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

2.  Determination of Fatty Acid Metabolism with Dynamic [11C]Palmitate Positron Emission Tomography of Mouse Heart In Vivo.

Authors:  Yinlin Li; Tao Huang; Xinyue Zhang; Min Zhong; Natalie N Walker; Jiang He; Stuart S Berr; Susanna R Keller; Bijoy K Kundu
Journal:  Mol Imaging       Date:  2015       Impact factor: 4.488

3.  Anesthesia and Preconditioning Induced Changes in Mouse Brain [18F] FDG Uptake and Kinetics.

Authors:  Pablo Bascuñana; James T Thackeray; M Bankstahl; Frank M Bengel; Jens P Bankstahl
Journal:  Mol Imaging Biol       Date:  2019-12       Impact factor: 3.488

4.  Simultaneous ECG-gated PET imaging of multiple mice.

Authors:  Jurgen Seidel; Marcelino L Bernardo; Karen J Wong; Biying Xu; Mark R Williams; Frank Kuo; Elaine M Jagoda; Falguni Basuli; Changhui Li; Gary L Griffiths; Michael V Green; Peter L Choyke
Journal:  Nucl Med Biol       Date:  2014-03-29       Impact factor: 2.408

5.  PET imaging detection of macrophages with a formyl peptide receptor antagonist.

Authors:  Yi Zhang; Bijoy Kundu; Min Zhong; Tao Huang; Jing Li; Mahendra D Chordia; Mei-Hua Chen; Dongfeng Pan; Jiang He; Weibin Shi
Journal:  Nucl Med Biol       Date:  2014-12-06       Impact factor: 2.408

Review 6.  Remodeling of glucose metabolism precedes pressure overload-induced left ventricular hypertrophy: review of a hypothesis.

Authors:  Bijoy K Kundu; Min Zhong; Shiraj Sen; Giovanni Davogustto; Susanna R Keller; Heinrich Taegtmeyer
Journal:  Cardiology       Date:  2015-03-12       Impact factor: 1.869

7.  Quantitative PET imaging detects early metabolic remodeling in a mouse model of pressure-overload left ventricular hypertrophy in vivo.

Authors:  Min Zhong; Clayton E Alonso; Heinrich Taegtmeyer; Bijoy K Kundu
Journal:  J Nucl Med       Date:  2013-02-20       Impact factor: 10.057

8.  Optimization of a Model Corrected Blood Input Function from Dynamic FDG-PET Images of Small Animal Heart In Vivo.

Authors:  Min Zhong; Bijoy K Kundu
Journal:  IEEE Trans Nucl Sci       Date:  2013-10       Impact factor: 1.679

9.  Combining MRI with PET for partial volume correction improves image-derived input functions in mice.

Authors:  Eleanor Evans; Guido Buonincontri; David Izquierdo; Carmen Methner; Rob C Hawkes; Richard E Ansorge; Thomas Krieg; T Adrian Carpenter; Stephen J Sawiak
Journal:  IEEE Trans Nucl Sci       Date:  2015-06-01       Impact factor: 1.679

10.  Glucose regulation of load-induced mTOR signaling and ER stress in mammalian heart.

Authors:  Shiraj Sen; Bijoy K Kundu; Henry Cheng-Ju Wu; S Shahrukh Hashmi; Patrick Guthrie; Landon W Locke; R Jack Roy; G Paul Matherne; Stuart S Berr; Matthew Terwelp; Brian Scott; Sylvia Carranza; O Howard Frazier; David K Glover; Wolfgang H Dillmann; Michael J Gambello; Mark L Entman; Heinrich Taegtmeyer
Journal:  J Am Heart Assoc       Date:  2013-05-17       Impact factor: 5.501

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.