Literature DB >> 20512783

Trabecular Metal buttress augment and the Trabecular Metal cup-cage construct in revision hip arthroplasty for severe acetabular bone loss and pelvic discontinuity.

Juan José Ballester Alfaro1, José Sueiro Fernández.   

Abstract

Large acetabular defects can be reconstructed using a tantalum Trabecular Metal acetabular component with Trabecular Metal buttress augments. We asked if these reconstructions survived at short-term follow-up. Of 35 patients undergoing acetabular reconstruction with a Trabecular Metal acetabular revision system from 2006, 19 acetabular revisions associated with major bone loss in which we reconstructed the acetabulum with buttress tantalum augments or cup-cage construct combined with a Trabecular Metal shell, were available for evaluation. Mean follow-up was 26 months (range 18-43 months). Mean patient age was 63 years, and 12 patients were women. All defects were classified according to Paprosky and Saleh classifications; there were 13 type IIIA and 6 type IIIB acetabular defects. Five chronic pelvic discontinuities were preoperatively or intraoperatively assessed (Saleh type 5) and a cup-cage construction was employed. No mechanical failure has occurred in any hip, and all patients have radiographically stable cups. Radiographic assessment showed an improvement in the position of the rotation centre of the hip, from a vertical position a mean of 3.5 cm (range 1.6-5.5 cm), to 1.4 cm (range 0.5-2.7 cm) postoperatively. The centre of the femoral head was relocated from a mean of 1.4 cm (range, -3 to 2.6 cm) lateral from the vertical at the teardrop to 3 cm (range 0.2-4 cm). Our early results suggest that buttress tantalum augments, with cup-cage construct for severe bone defects, may be an alternative to other treatment options, but a longer follow-up is necessary.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20512783     DOI: 10.5301/HIP.2010.5297

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  24 in total

1.  Pelvic discontinuity treated with custom triflange component: a reliable option.

Authors:  Michael J Taunton; Thomas K Fehring; Paul Edwards; Thomas Bernasek; Ginger E Holt; Michael J Christie
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  High failure rate with the GAP II ring and impacted allograft bone in severe acetabular defects.

Authors:  Martin A Buttaro; Diego Muñoz de la Rosa; Fernando Comba; Francisco Piccaluga
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

3.  Uncemented Porous Tantalum Acetabular Components: Early Follow-Up and Failures in 599 Revision Total Hip Arthroplasties.

Authors:  William J Long; Nicolas O Noiseux; Tad M Mabry; Arlen D Hanssen; David G Lewallen
Journal:  Iowa Orthop J       Date:  2015

Review 4.  Systematic review on outcomes of acetabular revisions with highly-porous metals.

Authors:  Samik Banerjee; Kimona Issa; Bhaveen H Kapadia; Robert Pivec; Harpal S Khanuja; Michael A Mont
Journal:  Int Orthop       Date:  2013-11-01       Impact factor: 3.075

5.  Management of Paprosky type three B acetabular defects by custom-made components: early results.

Authors:  Alessandro Aprato; Matteo Giachino; Paolo Bedino; Danilo Mellano; Raimondo Piana; Alessandro Massè
Journal:  Int Orthop       Date:  2018-10-16       Impact factor: 3.075

6.  Are custom triflange acetabular components effective for reconstruction of catastrophic bone loss?

Authors:  Carl C Berasi; Keith R Berend; Joanne B Adams; Erin L Ruh; Adolph V Lombardi
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

Review 7.  Treatment options for chronic pelvic discontinuity.

Authors:  Mark D Hasenauer; Wayne G Paprosky; Neil P Sheth
Journal:  J Clin Orthop Trauma       Date:  2017-09-18

8.  Surgical technique: a cup-in-cup technique to restore offset in severe protrusio acetabular defects.

Authors:  Thomas J Blumenfeld; William L Bargar
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

9.  Smoking may be a harbinger of early failure with ultraporous metal acetabular reconstruction.

Authors:  Adolph V Lombardi; Keith R Berend; Joanne B Adams; Ryan C Jefferson; Michael A Sneller
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

10.  Cup-cage construct for massive acetabular defect in revision hip arthroplasty- A case series with medium to long-term follow-up.

Authors:  Dan Arvinte; Manish Kiran; Manoj Sood
Journal:  J Clin Orthop Trauma       Date:  2019-04-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.