Literature DB >> 20511402

Dose reduction and image quality assessment in MDCT using AEC (D-DOM & Z-DOM) and in-plane bismuth shielding.

Kibaek Lee1, Wonho Lee, Junhyup Lee, Boram Lee, Gyubum Oh.   

Abstract

Since computed tomography (CT) was introduced about 40 y ago, its use has continuously grown, resulting in the increase of the CT dose. Therefore, an awareness of the CT dose and its potential complications has led to the development of several dose-reduction strategies. One of the strategies is automatic exposure control (AEC), which modulates radiation intensity depending on the patient size, z-axis thickness (Z-DOM) or angular thickness (D-DOM). Another dose-reduction method is the in-plane bismuth shield which attenuates radiation to reduce the CT doses of the tissues underneath the shield. We evaluated and compared the dose reduction and image quality of CT for various dose-reduction techniques. The result showed that both AEC and the in-plane shield reduced the CT dose effectively and the combined method of AEC and in-plane shielding reduced the CT dose more than the single use of AEC or in-plane shields. The dose reduction using Z-DOM was normally higher than that using D-DOM. The image quality of CT dramatically degraded when the in-plane shield was directly attached to the phantom without using AEC. In order to effectively reduce CT dose without the significant degradation of the image quality, the in-plane shield should be placed 1 cm apart from the patient with applying AEC control.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20511402     DOI: 10.1093/rpd/ncq159

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

1.  Bismuth shielding in CT: support for use in children.

Authors:  Sangroh Kim; Donald P Frush; Terry T Yoshizumi
Journal:  Pediatr Radiol       Date:  2010-08-24

2.  Excess of Radiation Burden for Young Testicular Cancer Patients using Automatic Exposure Control and Contrast Agent on Whole-body Computed Tomography Imaging.

Authors:  Hannele Niiniviita; Jarmo Kulmala; Tuukka Pölönen; Heli Määttänen; Hannu Järvinen; Eeva Salminen
Journal:  Radiol Oncol       Date:  2017-02-26       Impact factor: 2.991

3.  Bismuth shield affecting CT image quality and radiation dose in adjacent and distant zones relative to shielding surface: A phantom study.

Authors:  Ying-Lan Liao; Nan-Ku Lai; Yeu-Sheng Tyan; Hui-Yu Tsai
Journal:  Biomed J       Date:  2019-11-04       Impact factor: 4.910

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.