Literature DB >> 20508499

Effect of pulsatile blood flow on thrombosis potential with a step wall transition.

Scott C Corbett1, Amin Ajdari, Ahmet U Coskun, Hamid Nayeb-Hashemi.   

Abstract

It is well known that thrombus can be formed at stagnation regions in blood flow. However, studies of thrombus formation have typically focused on steady state flow. We hypothesize that pulsating flow may reduce persistent stagnation at the sites of low shear stress by decreasing exposure time. In this study, a step-wall transition, which is commonly found on implantable devices, is used as a test bed causing a recirculation vortex. Stagnation at such a step is considered using computational fluid dynamics studies and flow visualization experiments. Parametric studies were performed with varying step height, pulsatility, and velocity. The percentage of time along the wall with shear stresses below a threshold for thrombosis and the total length of wall that maintains contact with stagnant flow throughout the cardiac cycle are calculated. Persistent stagnation occurs at the corner of a step-wall transition in all cases and is observed to decrease with a decrease in step height, an increase in mean velocity, and an increase in pulsatility. Under steady flow conditions, a flow reattachment point resulting from recirculation is observed with expanding steps, whereas a flow separation point is observed with contracting steps. Pulsatility decreases persistent stagnation at the flow separation point with contracting steps, whereas it completely eliminates persistent stagnation at the flow reattachment point with expanding steps. The results of this work conclusively show that stagnation can be reduced by increasing pulsatility and flow velocity and by decreasing step height.

Entities:  

Mesh:

Year:  2010        PMID: 20508499     DOI: 10.1097/MAT.0b013e3181db2476

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  7 in total

Review 1.  Review of numerical methods for simulation of mechanical heart valves and the potential for blood clotting.

Authors:  Mohamad Shukri Zakaria; Farzad Ismail; Masaaki Tamagawa; Ahmad Fazli Abdul Aziz; Surjatin Wiriadidjaja; Adi Azrif Basri; Kamarul Arifin Ahmad
Journal:  Med Biol Eng Comput       Date:  2017-07-26       Impact factor: 2.602

Review 2.  In Vitro models for thrombogenicity testing of blood-recirculating medical devices.

Authors:  Deepika N Sarode; Shuvo Roy
Journal:  Expert Rev Med Devices       Date:  2019-06-10       Impact factor: 3.166

3.  Computational fluid dynamics-based study of possibility of generating pulsatile blood flow via a continuous-flow VAD.

Authors:  Erfan Nammakie; Hanieh Niroomand-Oscuii; Mojtaba Koochaki; Farzan Ghalichi
Journal:  Med Biol Eng Comput       Date:  2016-05-27       Impact factor: 2.602

4.  Generating pulsatility by pump speed modulation with continuous-flow total artificial heart in awake calves.

Authors:  Kiyotaka Fukamachi; Jamshid H Karimov; Gengo Sunagawa; David J Horvath; Nicole Byram; Barry D Kuban; Raymond Dessoffy; Shiva Sale; Leonard A R Golding; Nader Moazami
Journal:  J Artif Organs       Date:  2017-04-08       Impact factor: 1.731

Review 5.  Complications in children with ventricular assist devices: systematic review and meta-analyses.

Authors:  Andrea Nicola George; Tain-Yen Hsia; Silvia Schievano; Selim Bozkurt
Journal:  Heart Fail Rev       Date:  2021-03-04       Impact factor: 4.214

6.  Handling and performance characteristics of a new small caliber radiopaque embolic microsphere.

Authors:  Andrew L Lewis; Marcus Caine; Pedro Garcia; Koorosh Ashrafi; Yiqing Tang; Lorcan Hinchcliffe; Wei Guo; Zainab Bascal; Hugh Kilpatrick; Sean L Willis
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2020-06-23       Impact factor: 3.368

7.  Influences of Anatomorphological Features of the Portal Venous System on Postsplenectomy Hemodynamic Characteristics in Patients With Portal Hypertension: A Computational Model-Based Study.

Authors:  Tianqi Wang; Zunqiang Zhou; Fuyou Liang
Journal:  Front Physiol       Date:  2021-04-12       Impact factor: 4.566

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.