BACKGROUND: We sought to determine the efficacy of sutures, human fibrin glue and N-butyl-2-cyanoacrylate for mesh fixation in patients undergoing the plug and mesh procedure for groin hernia. METHODS: A total of 156 patients with 167 inguinal hernias (11 bilateral) underwent aplug and mesh procedure and were randomly assigned to received either sutures (n = 59 hernias), human fibrin glue (n = 52) or N-butyl-2-cyanoacrylate (n = 56) for mesh fixation. RESULTS: The overall morbidity rate was 38.98% in the suture group, 9.62% in the fibrin glue group and 10.71% in the N-butyl-2-cyanoacrylate group (suture v. fibrin glue, p < 0.001; suture v. N-butyl-2-cyanoacrylate, p < 0.001). There was no significant difference in morbidity between the fibrin glue and N-butyl-2-cyanoacrylate groups. Overall, short-term morbidity was significantly higher in the suture group (27.12%) than in the fibrin glue (9.62%, p = 0.01) or N-butyl-2-cyanoacrylate (8.93%, p = 0.004) groups, but there was no significant difference between the fibrin glue and N-butyl-2-cyanoacrylate groups. There was no significant difference between the groups in terms of mean postoperative stay (32.6 h in the suture group v. 30.8 h in the fibrin glue group v. 32.0 h in the N-butyl-2-cyanoacrylate group) or mean time to return to work (20.4 d in the suture group v. 20.3 d in the fibrin glue group v. 19.8 d in the N-butyl-2-cyanoacrylate group). Overall, long-term morbidity was significantly higher in the suture group (11.86%) than in the fibrin glue (0%, p = 0.001) or N-butyl-2-cyanoacrylate (1.78%, p = 0.03) groups. There was no recurrence in any of the groups. Two cases (3.39%) of chronic groin pain were reported in patients in the suture group. A sensation of extraneous body was reported in 5 (8.47%) patients who received sutures and in 1 (1.78%) patient in the N-butyl-2-cyanoacrylate group; there were no reported cases in the fibrin glue group (suture v. fibrin glue, p = 0.01; suture v. N-butyl-2-cyanoacrylate, p = 0.03; fibrin glue v. N-butyl-2-cyanoacrylate, p = 0.30). CONCLUSION: The use of human fibrin glue or N-butyl-2-cyanoacrylate is better tolerated than sutures in tension-free inguinal open repair using the plug and mesh technique in terms of overall immediate results, and there is a better trend in the long-term data.
RCT Entities:
BACKGROUND: We sought to determine the efficacy of sutures, human fibrin glue and N-butyl-2-cyanoacrylate for mesh fixation in patients undergoing the plug and mesh procedure for groin hernia. METHODS: A total of 156 patients with 167 inguinal hernias (11 bilateral) underwent a plug and mesh procedure and were randomly assigned to received either sutures (n = 59 hernias), human fibrin glue (n = 52) or N-butyl-2-cyanoacrylate (n = 56) for mesh fixation. RESULTS: The overall morbidity rate was 38.98% in the suture group, 9.62% in the fibrin glue group and 10.71% in the N-butyl-2-cyanoacrylate group (suture v. fibrin glue, p < 0.001; suture v. N-butyl-2-cyanoacrylate, p < 0.001). There was no significant difference in morbidity between the fibrin glue and N-butyl-2-cyanoacrylate groups. Overall, short-term morbidity was significantly higher in the suture group (27.12%) than in the fibrin glue (9.62%, p = 0.01) or N-butyl-2-cyanoacrylate (8.93%, p = 0.004) groups, but there was no significant difference between the fibrin glue and N-butyl-2-cyanoacrylate groups. There was no significant difference between the groups in terms of mean postoperative stay (32.6 h in the suture group v. 30.8 h in the fibrin glue group v. 32.0 h in the N-butyl-2-cyanoacrylate group) or mean time to return to work (20.4 d in the suture group v. 20.3 d in the fibrin glue group v. 19.8 d in the N-butyl-2-cyanoacrylate group). Overall, long-term morbidity was significantly higher in the suture group (11.86%) than in the fibrin glue (0%, p = 0.001) or N-butyl-2-cyanoacrylate (1.78%, p = 0.03) groups. There was no recurrence in any of the groups. Two cases (3.39%) of chronic groin pain were reported in patients in the suture group. A sensation of extraneous body was reported in 5 (8.47%) patients who received sutures and in 1 (1.78%) patient in the N-butyl-2-cyanoacrylate group; there were no reported cases in the fibrin glue group (suture v. fibrin glue, p = 0.01; suture v. N-butyl-2-cyanoacrylate, p = 0.03; fibrin glue v. N-butyl-2-cyanoacrylate, p = 0.30). CONCLUSION: The use of human fibrin glue or N-butyl-2-cyanoacrylate is better tolerated than sutures in tension-free inguinal open repair using the plug and mesh technique in terms of overall immediate results, and there is a better trend in the long-term data.
Authors: O Levrier; C Mekkaoui; P H Rolland; K Murphy; P Cabrol; G Moulin; J M Bartoli; C Raybaud Journal: J Neuroradiol Date: 2003-03 Impact factor: 3.447
Authors: R Fernández Lobato; J García Septiem; P Ortega Deballon; F J Martín Lucas; J C Ruíz de Adana; M Limones Esteban Journal: Int Surg Date: 2001 Oct-Dec
Authors: Amudha S Poobalan; Julie Bruce; W Cairns S Smith; Peter M King; Zygmunt H Krukowski; W Alastair Chambers Journal: Clin J Pain Date: 2003 Jan-Feb Impact factor: 3.442
Authors: David García Cerdá; Antonio Martín Ballester; Alicia Aliena-Valero; Anna Carabén-Redaño; José M Lloris Journal: Surg Today Date: 2014-10-25 Impact factor: 2.549
Authors: A Poli; F Parisi; F Millanta; L Solfanelli; P García-Pastor; C Magliaro; V Miragliotta; S Burchielli Journal: Hernia Date: 2019-11-26 Impact factor: 4.739