BACKGROUND AND
PURPOSE: To compare the efficacy and vascular toxicity of embolization with radical (NBCA+metacryloxysulpholane=CS) versus conventional anionic (NBCA alone=CA) polymerization of NBCA.
MATERIALS AND METHODS: Under continuous digital subtracted angiography (DSA) recordings, a 0.2 mL volume of identical glue mixtures were injected in a single-step procedure, concomitantly, in left and right (with CS and CA, respectively) renal arterial branches (RAB) and ascending pharyngeal arteries (APA) in 8 swines. Arterial histopathology and morphometry of inflammation were investigated at 2 weeks.
RESULTS: Complete embolization was achieved with equivalent cast homogeneity on DSA with both NBCA mixtures in RAB and APA. Inflammatory crowns in APA and RAB were significantly lower in CS - than in CA-treated sites (p<0.001). CS plug was scarcely adhesive to the vascular wall, and pulled apart from the wall by a residual thrombotic lining; in contrast with CA casts that were strongly adhesive to walls with endothelium stripping.
CONCLUSIONS: Anionic and radical polymerization of NBCA embolization was identical with regards to occlusion rate; whereas radical pathway of polymerization with cyanoacrylates lowered histotoxicity with a less sustained adhesiveness of casts against vascular walls.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12717295

Source DB:  PubMed          Journal:  J Neuroradiol        ISSN: 0150-9861            Impact factor:   3.447


  13 in total

1.  A single-surgeon randomized trial comparing sutures, N-butyl-2-cyanoacrylate and human fibrin glue for mesh fixation during primary inguinal hernia repair.

Authors:  Mario Testini; Germana Lissidini; Elisabetta Poli; Angela Gurrado; Domenica Lardo; Giuseppe Piccinni
Journal:  Can J Surg       Date:  2010-06       Impact factor: 2.089

Review 2.  Mesh fixation with glue versus suture for chronic pain and recurrence in Lichtenstein inguinal hernioplasty.

Authors:  Ping Sun; Xiang Cheng; Shichang Deng; Qinggang Hu; Yi Sun; Qichang Zheng
Journal:  Cochrane Database Syst Rev       Date:  2017-02-07

3.  Pain experience during internal spermatic vein embolization for varicocele: comparison of two cyanoacrylate glues.

Authors:  Sam Heye; Geert Maleux; Guido Wilms
Journal:  Eur Radiol       Date:  2005-07-06       Impact factor: 5.315

4.  Dual-lumen balloon catheters may improve liquid embolization of vascular malformations: an experimental study in Swine.

Authors:  J C Gentric; J Raymond; A Batista; I Salazkin; G Gevry; T E Darsaut
Journal:  AJNR Am J Neuroradiol       Date:  2015-01-15       Impact factor: 3.825

5.  Transsinusoidal portal vein embolization with ethylene vinyl alcohol copolymer (Onyx): a feasibility study in pigs.

Authors:  Maarten L J Smits; Peter Vanlangenhove; Emiel J C Sturm; Maurice A A J van den Bosch; Monirath Hav; Marleen Praet; Maarten A D Vente; Frédéric R Snaps; Luc Defreyne
Journal:  Cardiovasc Intervent Radiol       Date:  2011-10-07       Impact factor: 2.740

6.  Thermal gelation and tissue adhesion of biomimetic hydrogels.

Authors:  Sean A Burke; Marsha Ritter-Jones; Bruce P Lee; Phillip B Messersmith
Journal:  Biomed Mater       Date:  2007-09-24       Impact factor: 3.715

7.  Evaluation of the toxicity of onyx compared with n-butyl 2-cyanoacrylate in the subarachnoid space of a rabbit model: an experimental research.

Authors:  Bulent Bakar; Hakan H Oruckaptan; Burcu D Hazer; Isil Saatci; Pergin Atilla; Kamer Kilic; Sevda F Muftuoglu
Journal:  Neuroradiology       Date:  2009-09-15       Impact factor: 2.804

8.  Comparison of three different embolic materials for varicocele embolization: retrospective study of tolerance, radiation and recurrence rate.

Authors:  Nicolas Favard; Morgan Moulin; Patricia Fauque; Aurélie Bertaut; Sylvain Favelier; Louis Estivalet; Frédéric Michel; Luc Cormier; Paul Sagot; Romaric Loffroy
Journal:  Quant Imaging Med Surg       Date:  2015-12

9.  Guidelines for the use of NBCA in vascular embolization devised by the Committee of Practice Guidelines of the Japanese Society of Interventional Radiology (CGJSIR), 2012 edition.

Authors:  Yoshito Takeuchi; Hiroyuki Morishita; Yozo Sato; Shingo Hamaguchi; Noriaki Sakamoto; Hiroyuki Tokue; Takafumi Yonemitsu; Kenji Murakami; Hiroyasu Fujiwara; Keitaro Sofue; Toshi Abe; Hideyuki Higashihara; Yasuo Nakajima; Morio Sato
Journal:  Jpn J Radiol       Date:  2014-06-03       Impact factor: 2.374

10.  Comparison of four embolic materials for portal vein embolization: experimental study in pigs.

Authors:  Thierry de Baere; Alban Denys; Valerie Paradis
Journal:  Eur Radiol       Date:  2009-01-20       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.