Literature DB >> 2050708

Mechanical properties of metaphyseal bone in the proximal femur.

J C Lotz1, T N Gerhart, W C Hayes.   

Abstract

We used a three-point bending test to investigate the structural behavior of 123 rectangular flat plate specimens harvested from the metaphyseal shell of the cervical and intertrochanteric regions of five fresh/frozen human proximal femora. For comparison purposes, 36 specimens of similar geometry were also fabricated from bone of the femoral diaphysis. All specimens were oriented in either the local longitudinal or transverse directions. The mean longitudinal elastic modulus was 9650 +/- 2410 (SD) MPa and demonstrated a 24% decrease from that measured for the diaphysis (12500 +/- 2140 MPa) using the same testing technique. However, the transverse elastic moduli did not differ significantly between the proximal (5470 +/- 1720 MPa) and diaphyseal (5990 +/- 1520 MPa) specimens. The globally averaged values for the ultimate tensile strengths of the metaphyseal shell were 101 +/- 26 MPa in the longitudinal and 50 +/- 12 MPa in the transverse directions. These compared with diaphyseal values of 128 +/- 16 MPa and 47 +/- 12 MPa, respectively. While these differences were largely due to the reduced density of the proximal specimens, a slight decrease in transverse anisotropy for the proximal specimens was also noted by comparing the ratio of longitudinal to transverse moduli (1.76) and tensile strength (2.02) to the diaphyseal values (2.09 and 2.71, respectively). Use of these data should lead to improved performance of analytical models for the proximal femur, and thus help focus increased attention on the structural contribution of trabecular bone to the strength and rigidity of the proximal femur.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2050708     DOI: 10.1016/0021-9290(91)90350-v

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  34 in total

1.  Prediction of fracture healing under axial loading, shear loading and bending is possible using distortional and dilatational strains as determining mechanical stimuli.

Authors:  Malte Steiner; Lutz Claes; Anita Ignatius; Frank Niemeyer; Ulrich Simon; Tim Wehner
Journal:  J R Soc Interface       Date:  2013-07-03       Impact factor: 4.118

2.  Effects of hip abductor muscle forces and knee boundary conditions on femoral neck stresses during simulated falls.

Authors:  W J Choi; P A Cripton; S N Robinovitch
Journal:  Osteoporos Int       Date:  2014-07-16       Impact factor: 4.507

3.  The mechanical effects of different levels of cement penetration at the cement-bone interface.

Authors:  Daan Waanders; Dennis Janssen; Kenneth A Mann; Nico Verdonschot
Journal:  J Biomech       Date:  2010-04-19       Impact factor: 2.712

4.  Finite element model of the knee for investigation of injury mechanisms: development and validation.

Authors:  Ali Kiapour; Ata M Kiapour; Vikas Kaul; Carmen E Quatman; Samuel C Wordeman; Timothy E Hewett; Constantine K Demetropoulos; Vijay K Goel
Journal:  J Biomech Eng       Date:  2014-01       Impact factor: 2.097

5.  Transversely isotropic and isotropic material considerations in determining the mechanical response of geometrically accurate bovine tibia bone.

Authors:  Reem A Yassine; Ramsey F Hamade
Journal:  Med Biol Eng Comput       Date:  2019-08-03       Impact factor: 2.602

6.  Reduced diaphyseal strength associated with high intracortical vascular porosity within long bones of children with osteogenesis imperfecta.

Authors:  Carolyne Albert; John Jameson; Peter Smith; Gerald Harris
Journal:  Bone       Date:  2014-06-11       Impact factor: 4.398

Review 7.  The basic science of the subchondral bone.

Authors:  Henning Madry; C Niek van Dijk; Magdalena Mueller-Gerbl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-01-30       Impact factor: 4.342

8.  A surrogate long-bone model with osteoporotic material properties for biomechanical testing of fracture implants.

Authors:  Mark B Sommers; Daniel C Fitzpatrick; Steven M Madey; Corey Vande Zanderschulp; Michael Bottlang
Journal:  J Biomech       Date:  2007-06-18       Impact factor: 2.712

9.  Empirical measurements of biomechanical anisotropy of the human vocal fold lamina propria.

Authors:  Jordan E Kelleher; Thomas Siegmund; Mindy Du; Elhum Naseri; Roger W Chan
Journal:  Biomech Model Mechanobiol       Date:  2012-08-11

10.  Finite element analysis of the effect of cementing concepts on implant stability and cement fatigue failure.

Authors:  Dennis Janssen; Jantien van Aken; Thierry Scheerlinck; Nico Verdonschot
Journal:  Acta Orthop       Date:  2009-06       Impact factor: 3.717

View more