Literature DB >> 20506410

"Device landing zone" calcification, assessed by MSCT, as a predictive factor for pacemaker implantation after TAVI.

George Latsios1, Ulrich Gerckens, Lutz Buellesfeld, Ralf Mueller, Daniel John, Seyrani Yuecel, Joerg Syring, Barthel Sauren, Eberhard Grube.   

Abstract

BACKGROUND: After trans-catheter aortic valve implantation (TAVI), the need for postinterventional pacemaker (PM) implantation can occur in as many as 10-50% of cases, but it is not yet clear, how this need can be predicted. The aim of this study was to assess the possible predictive factors of post TAVI PM implantation based on Computed Tomography (CT) measured aortic valve calcification and its distribution.
METHODS: We prospectively analyzed 81 consecutive symptomatic patients with severe AS scheduled for TAVI using the CoreValve prosthesis (Medtronic, Minneapolis, USA). In all patients, a native and contrast-enhanced multislice cardiac CT was performed preinterventionally, estimating calcification load of the native valve cusps and of the adjacent outflow tract (so called "device landing zone", DLZ) by the Agatston Score (AgS). Objective, computer-evaluated, preprocedural ECG-analysis was performed with regards to pre-existing conduction abnormalities. Transthoracic echocardiography was performed pre and post TAVI.
RESULTS: TAVI was successful in all cases. PM implantation was deemed necessary in altogether 32 patients, out of 67 without a PM pre-TAVI (32/67, 47%). Various parameters were tested as predictors of post TAVI PM in a multivariate logistic regression analysis model. Female sex (P = 0,005) and depressed EF (P = 0,023) showed a significant correlation. PM implantation correlated also to the DLZ calcification, as assessed by CT (P = 0,004). This model leads to an AUC (area under the ROC-receiver operator characteristics-curve) of 0.83.
CONCLUSION: Calcium amount in the CoreValve DLZ in combination with clinical data could predict the need for post TAVI PM implantation.

Entities:  

Mesh:

Year:  2010        PMID: 20506410     DOI: 10.1002/ccd.22563

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  21 in total

Review 1.  Transcatheter aortic valve implantation-induced left bundle branch block: causes and consequences.

Authors:  Thomas T Poels; Patrick Houthuizen; Leen A F M Van Garsse; Jos G Maessen; Peter de Jaegere; Frits W Prinzen
Journal:  J Cardiovasc Transl Res       Date:  2014-05-07       Impact factor: 4.132

Review 2.  The Role of Multimodality Imaging in Transcatheter Aortic Valve Replacement.

Authors:  Qi Liu; Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2019-07-19       Impact factor: 2.931

3.  Predictors of paravalvular regurgitation and permanent pacemaker implantation after TAVR with a next-generation self-expanding device.

Authors:  Victor Mauri; Florian Deuschl; Thomas Frohn; Niklas Schofer; Matthias Linder; Elmar Kuhn; Andreas Schaefer; Volker Rudolph; Navid Madershahian; Lenard Conradi; Tanja K Rudolph; Ulrich Schäfer
Journal:  Clin Res Cardiol       Date:  2018-04-17       Impact factor: 5.460

Review 4.  New conduction abnormalities after TAVI--frequency and causes.

Authors:  Robert M van der Boon; Rutger-Jan Nuis; Nicolas M Van Mieghem; Luc Jordaens; Josep Rodés-Cabau; Ron T van Domburg; Patrick W Serruys; Robert H Anderson; Peter P T de Jaegere
Journal:  Nat Rev Cardiol       Date:  2012-05-01       Impact factor: 32.419

5.  Efficacy and safety of transcatheter aortic valve implantation in patients with severe bicuspid aortic stenosis.

Authors:  Bo Fu; Qingliang Chen; Feng Zhao; Zhigang Guo; Nan Jiang; Xu Wang; Wei Wang; Jiange Han; Li Yang; Yanbo Zhu; Yanhe Ma
Journal:  Ann Transl Med       Date:  2020-07

Review 6.  Advanced 3-D analysis, client-server systems, and cloud computing-Integration of cardiovascular imaging data into clinical workflows of transcatheter aortic valve replacement.

Authors:  Paul Schoenhagen; Mathis Zimmermann; Juergen Falkner
Journal:  Cardiovasc Diagn Ther       Date:  2013-06

Review 7.  Computed tomography in the evaluation for transcatheter aortic valve implantation (TAVI).

Authors:  Paul Schoenhagen; Jörg Hausleiter; Stephan Achenbach; Milind Y Desai; E Murat Tuzcu
Journal:  Cardiovasc Diagn Ther       Date:  2011-12

8.  The clinical anatomy and pathology of the human arterial valves: implications for repair or replacement.

Authors:  Michael G Bateman; Alexander J Hill; Jason L Quill; Paul A Iaizzo
Journal:  J Cardiovasc Transl Res       Date:  2013-01-17       Impact factor: 4.132

Review 9.  Transcatheter aortic valve repair, imaging, and electronic imaging health record.

Authors:  Paul Schoenhagen; Juergen Falkner; David Piraino
Journal:  Curr Cardiol Rep       Date:  2013-01       Impact factor: 2.931

10.  Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation for aortic stenosis using Medtronic new generation self-expanding CoreValve Evolut R.

Authors:  Hidehiro Kaneko; Frank Hoelschermann; Martin Seifert; Grit Tambor; Maki Okamoto; Viviane Moeller; Michael Neuss; Christian Butter
Journal:  Heart Vessels       Date:  2018-08-06       Impact factor: 2.037

View more