Literature DB >> 20503620

An objective evaluation method designed for pulsating cardiac phantom with 64-row MDCT.

Xiaolu Fei1, Xiangying Du, Mei Bai, Yan Li, Pengyu Li, Lan Wei, Kuncheng Li.   

Abstract

In the research of non-invasive cardiac coronary imaging with multi-detector CT (MDCT), it is necessary to use a standard cardiac phantom to perform the mass repetitive experiments. The standard phantom can help to investigate the regularity of a technology, and hence provide the instructions to clinic. In this study, an objective evaluation method of coronary stenosis rate, which can process CT images automatically, is developed with a cardiac phantom, to enhance working efficiency and to reduce subjective error. Several experiments were designed to verify the accuracy, the sensitivity and the consistency of this method. Based on the results, we found the accuracy of this objective method is within the clinical acceptable range. This method is sensitive to image quality change, and the results of the method are consistent without being affected by the environment and the operators. This proposed method can help to improve the efficiency of processing mass experimental data based on the cardiac phantom and establish a good foundation for the research on the cardiac coronary imaging with MDCT. This method is also applied to clinical images for tests and acceptable results are achieved in stenosis of low density.

Entities:  

Mesh:

Year:  2010        PMID: 20503620     DOI: 10.1007/s10916-008-9247-4

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  11 in total

1.  Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT.

Authors:  S Achenbach; S Ulzheimer; U Baum; M Kachelriess; D Ropers; T Giesler; W Bautz; W G Daniel; W A Kalender; W Moshage
Journal:  Circulation       Date:  2000-12-05       Impact factor: 29.690

2.  ACC/AHA guidelines for coronary angiography. A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee on Coronary Angiography). Developed in collaboration with the Society for Cardiac Angiography and Interventions.

Authors:  P J Scanlon; D P Faxon; A M Audet; B Carabello; G J Dehmer; K A Eagle; R D Legako; D F Leon; J A Murray; S E Nissen; C J Pepine; R M Watson; J L Ritchie; R J Gibbons; M D Cheitlin; T J Gardner; A Garson; R O Russell; T J Ryan; S C Smith
Journal:  J Am Coll Cardiol       Date:  1999-05       Impact factor: 24.094

3.  Small vessel stents for intracranial angioplasty: in vitro evaluation of in-stent stenoses using CT angiography.

Authors:  M Trossbach; M Hartmann; C Braun; K Sartor; S Hähnel
Journal:  Neuroradiology       Date:  2004-05-01       Impact factor: 2.804

4.  Advances in cardiac CT imaging: 64-slice scanner.

Authors:  Konstantin Nikolaou; Thomas Flohr; Andreas Knez; Carsten Rist; Bernd Wintersperger; Thorsten Johnson; Maximilian F Reiser; Christoph R Becker
Journal:  Int J Cardiovasc Imaging       Date:  2004-12       Impact factor: 2.357

5.  Objective evaluation of changes in left ventricular and atrial volumes during parabolic flight using real-time three-dimensional echocardiography.

Authors:  E G Caiani; L Sugeng; L Weinert; A Capderou; R M Lang; P Vaïda
Journal:  J Appl Physiol (1985)       Date:  2006-04-06

6.  Assessment of coronary plaque morphology by contrast-enhanced computed tomographic angiography: comparison with intravascular ultrasound.

Authors:  Margaret Leila Rasouli; David M Shavelle; William J French; Charles R McKay; Matthew J Budoff
Journal:  Coron Artery Dis       Date:  2006-05       Impact factor: 1.439

7.  Effect of dose-reduced scan protocols on cardiac coronary image quality with 64-row MDCT: a cardiac phantom study.

Authors:  Xiaolu Fei; Xiangying Du; Pengyu Li; Jingmin Liao; Yun Shen; Kuncheng Li
Journal:  Eur J Radiol       Date:  2007-08-31       Impact factor: 3.528

8.  64-MDCT coronary angiography: phantom study of effects of vascular attenuation on detection of coronary stenosis.

Authors:  Xiaolu Fei; Xiangying Du; Qi Yang; Yun Shen; Pengyu Li; Jingmin Liao; Kuncheng Li
Journal:  AJR Am J Roentgenol       Date:  2008-07       Impact factor: 3.959

9.  Anatomical M-mode: A novel technique for the quantitative evaluation of regional wall motion analysis during dobutamine echocardiography.

Authors:  J Chan; S Wahi; P Cain; T H Marwick
Journal:  Int J Card Imaging       Date:  2000-08

10.  Accuracy of 16-slice multi-detector CT to quantify the degree of coronary artery stenosis: assessment of cross-sectional and longitudinal vessel reconstructions.

Authors:  Ricardo C Cury; Maros Ferencik; Stephan Achenbach; Eugene Pomerantsev; Koen Nieman; Fabian Moselewski; Suhny Abbara; Ik-Kyung Jang; Thomas J Brady; Udo Hoffmann
Journal:  Eur J Radiol       Date:  2006-01-25       Impact factor: 3.528

View more